← Back
Nursing home
140 MOFFAT STREET
BROOKLYN · BIN 3080133
💬 Discuss this project
1982Year Built
7Stories
I6Building Class
R6Zoning
90,095 sfGross Floor Area
103Units
0 Open ViolationsFDNY Report ↗
Nursing home · 30,017 sf lot · 3 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Penthouse40p · 1 filing · 20 docs
Floor 441p · 1 filing · 20 docs
Floor 343p · 1 filing · 20 docs
Floor 241p · 1 filing · 20 docs
Floor 142p · 1 filing · 20 docs
1 job · most recent 03/25/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
03/25/2025Signed-offEAST COAST MANAGEMENT*Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric mitsubishi 48,000 BTU ×10
1 job · most recent 03/25/2025
Sprinkler System
FiledStatusContractorScope
03/25/2025Signed-offA&H EXPRESS PLBG&HTG CORPSprinkler System
1 job · most recent 03/25/2025
Storm Water/Sanitary
FiledStatusContractorScope
03/25/2025Signed-offA&H EXPRESS PLBG&HTG CORPStorm, Water/Sanitary
2 jobs · most recent 02/25/2025
General Wiring
FiledStatusContractorScope
02/25/2025CompleteTITANIUM ELECTRICAL CORPGeneral Wiring
03/05/2024CompleteTOP SHELF ELECTRIC CORP—
1 job · most recent 03/25/2025
Concrete Masonry
FiledStatusContractorScope
03/25/2025Signed-offEAST COAST MANAGEMENT*Concrete, Masonry
1 job · most recent 03/25/2025
Fence
FiledStatusContractorScope
03/25/2025Signed-offEAST COAST MANAGEMENT*Fence
Building Lifecycle
All (128)Filed (12)Permit Issued (14)Signed Off (7)Violation (12)Inspection (9)Objection (44)Special Inspection (30)
03/30/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-I1
03/12/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/30/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-S4
01/30/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-S5
01/29/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-S2
01/29/2026
Permit issued — Foundation
B00944181-S4-FO
01/29/2026
Permit issued — Structural
B00944181-S5-ST
01/27/2026
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-S3
08/22/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-S1
03/25/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-P5
03/20/2025
Special inspection requirement — Lighting in dwelling units
ROBERT SIQECA
03/20/2025
Special inspection requirement — Subgrade Inspections
ROBERT SIQECA
03/20/2025
Special inspection requirement — Lighting controls
ROBERT SIQECA
03/20/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
ROBERT SIQECA
03/20/2025
Special inspection requirement — Fenestration air leakage
ROBERT SIQECA
03/20/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
FAHAD FATEH
03/20/2025
Special inspection requirement — Fire-Resistance Rated Construction
ROBERT SIQECA
03/20/2025
Special inspection requirement — Metering
ROBERT SIQECA
03/20/2025
Special inspection requirement — Exterior lighting power
ROBERT SIQECA
03/20/2025
Special inspection requirement — Maintenance information
ROBERT SIQECA
03/20/2025
Special inspection requirement — Protection of exposed foundation insulation
ROBERT SIQECA
03/20/2025
Special inspection requirement — Interior lighting power
ROBERT SIQECA
03/20/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT SIQECA
03/20/2025
Special inspection requirement — Fenestration areas
ROBERT SIQECA
03/20/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT SIQECA
03/20/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT SIQECA
03/20/2025
Special inspection requirement — Preliminary
ROBERT SIQECA
03/20/2025
Special inspection requirement — Insulation placement and R values
ROBERT SIQECA
03/20/2025
Special inspection requirement — Concrete - Cast-In-Place
ROBERT SIQECA
03/20/2025
Special inspection requirement — Masonry
ROBERT SIQECA
03/20/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT SIQECA
03/20/2025
Special inspection requirement — Construction Operations Influencing Adjacent Structures
ROBERT SIQECA
03/18/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/29/2025
Objection resolved — Addressed
01/21/2025
Objection raised — Other
01/10/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-P4
11/21/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/30/2024
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
10/30/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
08/22/2024
Signed off — Alteration
INSTALLATION OF A HEAVY DUTY SIDEWALK SHED AS PER PLANS DURING GENERAL CONSTRUCTION WORK. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED TO COMPLY WITH CHAPTER 33 OF NYC BUILDING CODE.
B01015721-I1
08/13/2024
Permit issued — General Construction
B00944181-I1-GC
07/01/2024
Permit issued — Structural
B00944181-S5-ST
06/21/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/21/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/21/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/21/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
FAHAD FATEH
06/21/2024
Special inspection requirement — Energy Code Compliance Inspections
ROBERT SIQECA
06/21/2024
Special inspection requirement — Air barrier - visual inspection
ROBERT SIQECA
06/21/2024
Special inspection requirement — Concrete - Cast-In-Place
ROBERT SIQECA
06/21/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT SIQECA
06/21/2024
Special inspection requirement — Masonry
ROBERT SIQECA
06/21/2024
Special inspection requirement — Subgrade Inspections
ROBERT SIQECA
06/21/2024
Special inspection requirement — Construction Operations Influencing Adjacent Structures
ROBERT SIQECA
06/20/2024
Permit issued — General Construction
B00944181-I1-GC
06/06/2024
Violation issued (ECB, closed)
Construction
05/23/2024
Permit issued — Foundation
B00944181-S4-FO
05/15/2024
Objection raised — Scope
05/15/2024
Objection resolved — Addressed
05/14/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New vertical enlargement for 4 story and penthouse, 5 dwelling unit on existing 3 family 3 story building,
B00944181-P3
Latest 60 of 128 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
UNIVERSAL SYSTEMS404/09/2026
140 ON LLC203/22/2026
COAST MANAGEMENT * EAST103/22/2026
EAST COAST MANAGEMENT103/22/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
INFOCUS DESIGN AND PLANNING PC803/21/2026
BANJI ARCHITECT PC303/21/2026
EUROCELT EXPEDITING, INC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
EAST COAST MANAGEMENT*General Contractor1107/08/2026
DEPENDABLE MECHANICAL CORFire Protection107/08/2026
UNIVERSAL SYSTEMS INCGeneral Contractor104/09/2026
A&H EXPRESS PLBG&HTG CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
STRUCTURAL ENGINEERING &56991003/25/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWFoundationSigned-offEAST COAST MANAGEMENT*01/29/2026
DOB NOWStructuralSigned-offEAST COAST MANAGEMENT*01/29/2026
DOB NOWGeneral ConstructionPermit IssuedEAST COAST MANAGEMENT*08/13/2024
DOB NOWStructuralSigned-offEAST COAST MANAGEMENT*07/01/2024
DOB NOWGeneral ConstructionPermit IssuedEAST COAST MANAGEMENT*06/20/2024
DOB NOWFoundationSigned-offEAST COAST MANAGEMENT*05/23/2024
DOB NOWPlumbingSigned-offA&H EXPRESS PLBG&HTG CORP03/19/2024
DOB NOWPlumbingSigned-offDEPENDABLE MECHANICAL COR03/19/2024
DOB NOWSidewalk ShedSigned-offUNIVERSAL SYSTEMS INC03/08/2024
DOB NOWStructuralSigned-offEAST COAST MANAGEMENT*03/06/2024
DOB NOWGeneral ConstructionPermit IssuedEAST COAST MANAGEMENT*02/20/2024
DOB NOWFoundationSigned-offEAST COAST MANAGEMENT*02/14/2024
DOB NOWMechanical SystemsSigned-offEAST COAST MANAGEMENT*02/06/2024
DOB NOWConstruction FenceSigned-offEAST COAST MANAGEMENT*01/25/2024
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
03/12/2026Pass-Final CND-Occupancy InspectionPassView ↗
03/18/2025Pass-Final CND-Occupancy InspectionPassView ↗
11/21/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/30/2024Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
10/30/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/21/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/21/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/21/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 107
DateRequirementInspectorRole
03/20/2025Fire-Resistance Rated ConstructionROBERT SIQECAprogress
03/20/2025Energy Code Compliance InspectionsROBERT SIQECAprogress
03/20/2025Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
03/20/2025Subgrade InspectionsROBERT SIQECAspecial
03/20/2025Structural Stability – Alterations of existing buildingsROBERT SIQECAspecial
03/20/2025MasonryROBERT SIQECAspecial
03/20/2025Fire-Resistant Penetrations and JointsROBERT SIQECAspecial
03/20/2025Construction Operations Influencing Adjacent StructuresROBERT SIQECAspecial
03/20/2025Concrete - Cast-In-PlaceROBERT SIQECAspecial
03/20/2025Fenestration air leakageROBERT SIQECAenergy_progress
03/20/2025Interior lighting powerROBERT SIQECAenergy_progress
03/20/2025Air barrier - visual inspectionROBERT SIQECAenergy_progress
03/20/2025Fenestration areasROBERT SIQECAenergy_progress
03/20/2025Protection of exposed foundation insulationROBERT SIQECAenergy_progress
03/20/2025Lighting in dwelling unitsROBERT SIQECAenergy_progress
03/20/2025Fenestration and door U-factor and product ratingsROBERT SIQECAenergy_progress
03/20/2025Maintenance informationROBERT SIQECAenergy_progress
03/20/2025Exterior lighting powerROBERT SIQECAenergy_progress
03/20/2025Lighting controlsROBERT SIQECAenergy_progress
03/20/2025MeteringROBERT SIQECAenergy_progress
03/20/2025Insulation placement and R valuesROBERT SIQECAenergy_progress
03/20/2025PreliminaryROBERT SIQECAprogress
06/21/2024Energy Code Compliance InspectionsROBERT SIQECAprogress
06/21/2024PreliminaryROBERT SIQECAprogress
06/21/2024Protection of exposed foundation insulationROBERT SIQECAenergy_progress
Latest 25 of 107.
▾Documents — 143 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/25/2026B01015721-I1Request digital key ↗
08/25/2026B00944181-P5Request digital key ↗
08/25/2026B00944181-P4Request digital key ↗
Showing 3 of 12 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION5
01/29/2026340905907Open ↗
06/27/2025322119667Open ↗
06/17/2025322119667Open ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records13
▸DOB NOWZD1: DOB Zoning Diagram4
08/13/2026B00944181-P4Open ↗
08/13/2026B00944181-P5Open ↗
08/13/2026B00944181-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWZoning Exhibit form (1-5)4
08/13/2026B00944181-P4Open ↗
08/13/2026B00944181-P1Open ↗
08/13/2026B00944181-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
06/26/2025322119667Open ↗
▸BISZONING EXHIBIT III:DESC. & OWNRSHP.STMNT1
06/26/2025322119667Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
06/26/2025322119667Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
06/26/2025322119667Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00944181-I1Open ↗
▸Seals & Professional Certifications64
▸DOB NOWSpecial Inspector Seal & Signature30
09/23/2026B00944181-P3Open ↗
09/02/2026B00944181-P1Open ↗
09/02/2026B00944181-P1Open ↗
Showing 3 of 30 on file for this type
▸DOB NOWProgress Inspector Seal & Signature21
09/29/2026B00944181-P2Open ↗
09/23/2026B00944181-P3Open ↗
09/23/2026B00944181-P3Open ↗
Showing 3 of 21 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/25/2026B00944181-P5Open ↗
08/25/2026B00944181-I1Open ↗
08/25/2026B00944181-P4Open ↗
Showing 3 of 12 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
11/14/2023340905907Open ↗
▸Trade Schedules & Equipment4
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)4
08/13/2026B00944181-I1Open ↗
08/13/2026B00944181-P5Open ↗
08/13/2026B00944181-P1Open ↗
Showing 3 of 4 on file for this type
▸Safety & Tenant Protection6
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
11/14/2023340905907Open ↗
▸BISBPP: STREET TREES SITE PLAN1
11/14/2023340905907Open ↗
▸BISSTREET TREE CHECKLIST1
03/06/2026340905907Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00944181-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00944181-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00944181-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/25/2026B00944181-S2Open ↗
08/25/2026B00944181-I1Open ↗
08/25/2026B00944181-S3Open ↗
Showing 3 of 10 on file for this type
▸Inspections & Test Reports6
▸DOB NOWSOIL REPORT4
08/13/2026B00944181-P4Open ↗
08/13/2026B00944181-P5Open ↗
08/13/2026B00944181-P1Open ↗
Showing 3 of 4 on file for this type
▸BISBPP-9 - Request for Builders Pavement Field Inspection1
03/06/2026340905907Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00944181-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISBPP-11 - Affidavit as to Roadway Pavement And/Or Sidewalk and Curb Construction1
03/06/2026340905907Open ↗
▸Filing & Intake Forms4
▸BISBOROUGH INTAKE FORM1
11/08/2024322119667Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
03/06/2026340905907Open ↗
▸BISEFILING COVER SHEET1
11/08/2024322119667Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
11/14/2023340905907Open ↗
▸Other Documents18
▸DOB NOWSite Survey: Initial4
08/13/2026B00944181-I1Open ↗
08/13/2026B00944181-P4Open ↗
08/13/2026B00944181-P5Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone4
08/13/2026B00944181-P5Open ↗
08/13/2026B00944181-P1Open ↗
08/13/2026B00944181-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification4
08/25/2026B00944181-P4Open ↗
08/25/2026B00944181-P5Open ↗
08/25/2026B00944181-I1Open ↗
Showing 3 of 4 on file for this type
▸BISCONSTRUCTION - SUPPORTING DOCUMENTATION3
06/26/2025322119667Open ↗
06/26/2025322119667Open ↗
06/26/2025322119667Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
06/26/2025322119667Open ↗
▸BISPLOT DIAGRAM1
06/26/2025322119667Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00944181-I1Open ↗