ECB03/27/2023BOTH EMERGENCY DOORS FOR THE ROOF AND GROUND LEVEL DO NOT SELF CLOSE., REPAIR AND/OR REPLACE; REPAIR AND OR REPLACE$3K due
ECB12/23/2025CLASS 2. TWO DIFFERENT CAPACITY NUMBERS SHOWN ON THE TAGS ON THE PLATFORM, PROVIDE CORRECT NUMBER, REMOVE A WRONG ONE. STAIR LIFT COULD NOT BE OPERATED DURING INSPECTION. NO BUILDING PERSONNEL WERE ABLE TO DEMONothing owed — awaiting certificate of correction
ECB12/23/2025OBSERVED THROUGHOUT THE BUILDING SPRINKLER HEADS OBSTRUCTED. IN BASEMENT LACK SUPPORT ON SPRINKLER LINE, USING SHARK BITE FITTINGS ON WATER LINES, JIM CAPS ON WASTE LINES, GAS LINES AND SPRINKLER LINES CORRODEDNothing owed — awaiting certificate of correction
ECB12/23/2025CLASS 2: EMERGENCY PHONE INOPERATIVE - RESPONDING SIDE UNABLE TO HEAR PERSON IN THE CAR, PROVIDE CLEAR 2 WAY COMMUNICATION.Nothing owed — awaiting certificate of correction
ECB12/23/2025FAILURE TO SAFEGUARD THE PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. PARTITION WALL ERECTED OBSTRUCTING EGRESS ON GROUND FLOOR LEVEL. NO PERMITS ON FILE, SAFEGUARD PUBLIC AND PROPERTYNothing owed — awaiting certificate of correction
ECB12/23/2025FEDERAL BOILER MODEL# FST-500. MISSING BODY DRAINS ON RELIEF VALVES, MISSING SIGHT GLASS AND HOLDER ON REAR DOOR. CORRECT VIOLATING CONDITIONS AND SUBMIT A CERTIFICATE OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB12/23/2025CLASS 2: MISSI NG MAINTENANCE RECORD FOR OCTOBER 2025, CONDUCT ROUTINE SERVICE AND UPDATE THE RECORDSNothing owed — awaiting certificate of correction
ECB12/23/2025WORK WITHOUT A PERMIT. PARTITION WALL ERECTED WITHOUT PERMITS ON FILE, OBTAIN PERMITNothing owed — awaiting certificate of correction
ECB04/10/2025#2 FEDERAL STEAM BOILER IS MISSING REAR FLAME SIGHT GLASS+SAFETY VALVES MISSING BODY DRAIN DISCHARGE PIPES+COMBUSTION AIR FAN MISSING AIR PROVING SWITCHES+COMBUSTION AIR FAN HAS WORN BEARINGSÝNOISE+VIBRATION¨+CNothing owed — awaiting certificate of correction
ECB05/29/2024UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 35657506L ISSUED ON 04/25/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. (FAILUNothing owed — awaiting certificate of correction
ECB05/29/2024UNLAWFUL ACTS: FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER CONTAINED IN SUMMONS/VIOLATION# 35657505J ISSUED ON 04/25/2023 AND TO FILE A CERTIFICATE OF CORRECTION PURSUANT TO 28-201.1 AND 1RCNY 102-01. (FAILUNothing owed — awaiting certificate of correction
ECB02/23/2024UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB #35657505J ISSUED ON 04/25/2023 AND FILE A CERTIFICATE OF CORRECTION AS PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSIONothing owed — awaiting certificate of correction
ECB02/23/2024UNLAWFUL ACTS: FAILURE TO COMPLY WITH COMMISSIONER'S ORDERS AS STATED IN ECB #35657506L ISSUED ON 04/25/2023 AND FILE A CERTIFICATE OF CORRECTION AS PURSUANT TO 28-201.1 AND 1RCNY 102-01., COMPLY WITH COMMISSIONothing owed — awaiting certificate of correction
ECB11/15/2023I OBSERVED AT THE ENTRANCE TO THE BOILER ROOM THE LACK OF LIGHTING/ILLUMINATION REQUIRED AT POINTS OF EGRESS., COMPLY WITH EC; PROVIDE/MAINTAIN ILLUMINATION.Nothing owed — awaiting certificate of correction
ECB11/14/2023HOLE PENETRATIONS ON THE WALL AND CEILING OF THE CELLAR LEVEL AND NO FIRE STOPPING AROUND PIPING., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB10/11/2023FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 04252023COBMEJ01, DATED 4/25/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/Nothing owed — awaiting certificate of correction
ECB10/11/2023FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER IN DOB VIOLATION 04252023COBMEJ01, DATED 4/25/2023. RESPONDENT WAS REQUIRED TO SUBMIT AN ENGINEER'S REPORT CONCERNING STRUCTURALLY DEFICIENT CONDITIONS. AS OF 10/Nothing owed — awaiting certificate of correction
ECB07/24/2023TWO STORY BUILDING OBSERVED ON THE 14TH SIDE OF BUILDING TWO STEPPING CRACKS ONE IS APPROX. 10 FEET AND 4 FEET, JUST WEST OF ENTRANCE TO BUILDING AND ALONG PEDESTRIAN WALKWAY., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB06/26/2023FAILURE TO MAINTAIN BUILDING WALLS AND/OR APPURTENANCES. NOTE:OBSERVEDIN SEVERAL PLACES AROUND THE EXTERIOR OF THE BLDG,RUNNING CRACKS IN FACADE,AREAS WHERE THE BROWNSTONE HAS BROKEN OFF AND FALLEN,AND SECTIONNothing owed — awaiting certificate of correction
ECB06/26/2023FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTE:OBSERVED IN YMCA,AREAS OF THE FLOOR ARE SINKING AND CRACKED AND CLOSED OFF FROM USE,AND IN THE AREA OF THE CELLAR UNDER THE ATHLETIC FIELD. THERE ARENothing owed — awaiting certificate of correction
ECB03/27/2023-CRACKS ON THE PARAPET AND DORMITORY STRUCTURE WALLS ON ROOF. (VOILATION NO.39062303Y- DATE: 05/17/2022)., REPAIR AND/OR REPLACE; REPAIR AND OR REPLACENothing owed — awaiting certificate of correction
ECB03/27/2023-FIRESTOP NEEDED IN MULTIPLE ROOMS ON CEILING OF 3RD FLOOR AND EMERGENCY DOORS PASSAGEWAYS ALSO LEADING TO THE ROOF., PROVIDE/MAINTAIN FIRE STOPPING; PROVIDE/MAINTAIN FIRE STOPPINGNothing owed — awaiting certificate of correction
ECB03/27/2023-PARTICAL BOARD SHEETHING INSTALLED IN 3RD FLOOR CORRIDOR/HALLWAY LEADING TO ROOF COVERING EXITING FIRE RATED WALLS., MAINTAIN EXTERIOR BUILDING WALL; REPAIR WALL PROPERLYNothing owed — awaiting certificate of correction
ECB03/27/2023-SLIDING BOLT LOCKS ILLEGALLY INSTALLED ON DORMITORY DOORS. (VIOLATION NO.39062306J - DATE; 05/17/2022., PROVIDE LEGAL HARDWARE; PROVIDE LEGAL HARDWARENothing owed — awaiting certificate of correction
ECB02/07/2023BODY DRAIN PIPES MISSING AT SAFETY RELIEF VALVES, KING VALVE LEAKING ONTO BOILER, FRESH AIR FAN OUTSIDE LOUVER PARTIALLY CLOGGED/ FAN MISSING AIR PROVING SWITCH INTERLOCKED WITH 2 BOILERS + 4 HWH'S, CORRECT ALLNothing owed — awaiting certificate of correction
ECB07/27/2022BODY DRAIN PIPES MISSING AT SAFETY VALVES/KING VALVE LEAKING ONTO BOILER/FRESH AIR FAN OUTSIDE LOUVER 1/2 CLOGGED/FAN MISSING AIR PROVING SWITCH INTERLOCKED WITH 2 BOILERS+4 HWH'S;CORRECT VIOLATION AND SUBMIT TNothing owed — awaiting certificate of correction
ECB06/07/2022NOTED: OBSERVED AT CELLAR'S ELECTRICAL ROOM, PIPES AND CONDUITS PENETRATING THROUGH WALLS INTO ADJACENT AREAS WITH NO FIRE STOPPING PROVIDED., PROVIDE/MAINTAIN FIRE STOPPINGNothing owed — awaiting certificate of correction
ECB06/07/2022NOTED: FIREPROOF SELF CLOSING DORMITORY AND OFFICE DOORS ARE NOT SELF CLOSING, DOORS REMAIN IN AN OPEN POSITION WHEN OPENED., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB06/07/2022NOTED: OBSERVED AT CELLAR'S GAS METER ROOM, WATER METER AREAS EXPOSED DECKING AND STEEL BEAMS WITH NO FIREPROOFING PROVIDED., REPAIR AND/OR REPLACENothing owed — awaiting certificate of correction
ECB06/07/2022NOTED: OBSERVED AT 2ND FLOOR, ILLEGAL SLIDE BOLT WITH LOCKS INSTALLED ON ALL DORMITORY DOORS., PROVIDE LEGAL HARDWARENothing owed — awaiting certificate of correction
ECB06/07/2022NOTED: OBSERVED HORIZONTAL AND VERTICAL CRACKS THROUGH BRICKS AT NORTH AND SOUTH ELEVATION, MISSING BRICK MORTAR AT VARIOUS LOCATIONS THROUGHOUT EXTERIOR WALLS., MAINTAIN EXTERIOR BUILDING WALLNothing owed — awaiting certificate of correction
ECB03/16/2020NOTED: OBSERVED AT EXPOSURE #2 (SOUTH ELEVATION) AND EXPOSURE #4 (NORTH ELEVATION), VERTICAL AND HORIZONTAL CRACKS THROUGH BRICKS AT VARIOUS LOCATIONS, HOLE IN BRICK AT EXP.#2 AND #4, MISSING BRICK JOINT MORTARNothing owed — awaiting certificate of correction
ECB07/28/2017FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTE: @ BOILER ROOMFIRE PROOFING IS MISSING FROM STEEL, NEW STEEL DECK NO FIRE PROOFING DONE. REMEDY: REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/28/2017ELECTRICAL WORK W/O A PERMIT. OBSERVED 4 HVAC SYSTEMS WITH SERVICE SWITCHES & A GFCL RECEPTUCLE OUTLET INSTALLED & WIRED ON ROOF TOP AREA. THIS WORK ISN'T COVERED UNDER ANY PREVIOUS ELECTRICAL APPL. REMEDY: COMNothing owed — awaiting certificate of correction