1958Year Built
14Stories
D4Building Class
R6Zoning
445,950 sfGross Floor Area
423Units
LL97 CoveredRent Stabilized37 Open Violations 36 unresolved · 1 paperwork only ▸FISP: SAFEFDNY Report ↗
Elevator cooperative · Owner of record: EARL W JIMERSON HOUSING CO INC · 197,000 sf lot · 2.26 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 10 docs
Floor 14Under Construction11p · 2 filings · 20 docs
Floor 13Under Construction7p · 1 filing · 8 docs
Floor 12Under Construction7p · 1 filing · 8 docs
Floor 11Under Construction7p · 1 filing · 8 docs
Floor 10Under Construction7p · 1 filing · 8 docs
Floor 9Under Construction7p · 1 filing · 8 docs
Floor 8Under Construction7p · 1 filing · 8 docs
Floor 7Under Construction7p · 1 filing · 8 docs
Floor 6Under Construction7p · 1 filing · 8 docs
Floor 5Under Construction7p · 1 filing · 8 docs
Floor 4Under Construction7p · 1 filing · 8 docs
Floor 3Under Construction7p · 1 filing · 8 docs
Floor 2Under Construction7p · 1 filing · 8 docs
Floor 1Under Construction7p · 1 filing · 8 docs
BasementUnder Construction1p · 1 filing · 14 docs
Sub-BasementUnder Construction34p · 3 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SUMMIT PROPERTY MANAGEMENT SERVICES906/28/2026
MARION SCOTT REAL ESTATE INC.504/09/2026
EARL W JIMERSON HOUSING1803/22/2026
MARION SCOTT REALTY103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RJ STAHL ARCHITECT, PC310/29/2025
RLM ENGINEERING PLLC310/23/2025
STAVROS I. MALLIAROS, P.E., P.C.103/07/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
P WOLFE CONSULTANTS603/21/2026
BAY RESTORATION203/21/2026
MARTELL SOLUTIONS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BAY RESTORATION CORPGeneral Contractor307/08/2026
ESPOSITO, RICHARDElectrical103/21/2026
RICHARD ESPOSITOElectrical103/21/2026
ELMHURST ELECTRIC CORPGeneral Contractor106/02/2026
NOBLE MECHANICAL CORPGeneral Contractor106/28/2026
NOBLE MECHANICAL CORPPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CO4ARCHITECTURE.PC4603110/29/2025
ASE ENGINEERING PLLC5785210/23/2025
RLM ENGINEERING PLLC6913310/23/2025
Building Lifecycle
All (158)Filed (9)Permit Issued (8)Signed Off (1)Facade (FISP) (19)Violation (59)Objection (36)Special Inspection (26)
07/31/2026
Cycle 10 facade report signed — SWARMP
07/10/2026
Cycle 10 facade inspection completed
06/11/2026
Cycle 10 facade report submitted
06/02/2026
Permit issued — Plumbing
B01306059-I1-PL
04/25/2026
Violation issued (HPD, open)
B
04/25/2026
Violation issued (HPD, open)
B
04/25/2026
Violation issued (HPD, open)
C
04/25/2026
Violation issued (HPD, open)
A
04/25/2026
Violation issued (HPD, closed)
C
04/25/2026
Violation issued (HPD, open)
B
04/25/2026
Violation issued (HPD, open)
B
04/25/2026
Violation issued (HPD, open)
A
04/24/2026
Violation issued (HPD, open)
C
04/24/2026
Violation issued (HPD, open)
B
03/02/2026
Permit issued — Suspended Scaffold
B01363874-I1-SC
02/24/2026
Filed — Alteration
GAS MATERIAL HOIST DURING ROOF REPLACEMENT
B01363874-I1
02/24/2026
Permit issued — General Construction
B01301001-I1-GC
12/29/2025
Objection resolved — Addressed
12/05/2025
Cycle 9 facade report submitted
12/05/2025
Cycle 9 facade report signed — SAFE
12/04/2025
Signed off — Alteration
B08002477-I1
12/02/2025
Objection resolved — Addressed
12/02/2025
Objection resolved — Addressed
12/02/2025
Objection resolved — Addressed
11/18/2025
Permit issued — Mechanical Systems
B01303094-S1-MS
11/17/2025
Objection resolved — Addressed
11/17/2025
Special inspection requirement — Post-installed Anchors
alon egozi
11/14/2025
Objection raised — Cost
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/12/2025
Objection resolved — Addressed
11/07/2025
Cycle 9 facade inspection completed
11/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
STEPHEN THOMSON
11/06/2025
Objection raised — Structural
11/06/2025
Objection raised — Scope
11/06/2025
Objection raised — Scope
11/06/2025
Objection raised — Scope
11/06/2025
Objection raised — Cost
11/06/2025
Objection raised — Scope
11/06/2025
Objection raised — Scope
11/06/2025
Objection raised — Scope
11/04/2025
Objection resolved — Addressed
11/04/2025
Objection resolved — Addressed
10/29/2025
Filed — Alteration
Filing for Lobby Renovations, Exterior Pergola and PA Community Room Renovation. No change to Use, Egress of Occupancy.
B01301001-I1
10/29/2025
Filed — Alteration
B08002477-P1
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Other
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Scope
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection raised — Plumbing
10/29/2025
Objection resolved — Addressed
Latest 60 of 158 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedNOBLE MECHANICAL CORP06/02/2026
DOB NOWSuspended ScaffoldPermit IssuedBAY RESTORATION CORP03/02/2026
DOB NOWGeneral ConstructionPermit IssuedELMHURST ELECTRIC CORP02/24/2026
DOB NOWMechanical SystemsPermit IssuedNOBLE MECHANICAL CORP11/18/2025
DOB NOWSidewalk ShedPermit IssuedBAY RESTORATION CORP03/07/2025
DOB NOWGeneral ConstructionSigned-offBAY RESTORATION CORP10/17/2024
DOB NOWSuspended ScaffoldPermit IssuedBAY RESTORATION CORP08/09/2024
DOB NOWGeneral ConstructionSigned-offBAY RESTORATION CORP10/22/2022
BISOTISSUEDPOFI CONSTRUCTION CORP09/17/2018
BISEQISSUEDROCKLEDGE SCAFFOLD CORP09/24/2013
BISOTISSUEDA P A RESTORATION CORP05/07/2013
BISOTISSUEDA P A RESTORATION CORP05/07/2013
BISPLISSUEDLLOYD G DRUMMOND PLBG&GEN01/30/2013
BISOTISSUEDWALL CONTRACTOR CORP01/22/2013
BISOTISSUEDA P A RESTORATION CORP11/02/2012
BISEQISSUEDROCKLEDGE SCAFFOLD CORP10/18/2012
BISOTISSUEDA P A RESTORATION CORP06/13/2012
BISEQISSUEDROCKLEDGE SCAFFOLD CORP11/03/2011
BISOTISSUEDA P A RESTORATION CORP04/18/2011
BISOTISSUEDA P A RESTORATION CORP03/29/2011
BISEQISSUEDROCKLEDGE SCAFFOLD CORP11/09/2010
BISEQISSUEDROCKLEDGE SCAFFOLD CORP11/09/2009
BISOTISSUEDPROTO CONSTRUCTION AND DEVELOPME04/05/2000
BISOTISSUEDPROTO CONSTRUCTION AND DEVELOPME08/05/1999
2 projects · most recent 10/23/2025
Water/Sanitary
FiledStatusContractorScope
10/23/2025Permit IssuedNOBLE MECHANICAL CORPWater/Sanitary
10/23/2025——Water/Sanitary
1 project · most recent 02/15/2018
FiledStatusContractorScope
02/15/2018CompleteALL WAYS ELECTRIC CORP.W—
1 project · most recent 03/07/2025
Sidewalk Shed
FiledStatusContractorScope
03/07/2025Permit IssuedBAY RESTORATION CORPSidewalk Shed
1 project · most recent 02/24/2026
Suspended Scaffold
FiledStatusContractorScope
02/24/2026Permit IssuedBAY RESTORATION CORPSuspended Scaffold
2 projects · most recent 02/24/2026
Suspended Scaffold (SC)
FiledStatusContractorScope
02/24/2026Permit IssuedBAY RESTORATION CORPSuspended Scaffold (SC)
07/29/2024Permit Issued—Suspended Scaffold (SC)
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
11/17/2025Post-installed Anchorsalon egozispecial
11/07/2025Structural Stability – Alterations of existing buildingsSTEPHEN THOMSONspecial
10/29/2025Post-installed Anchorsalon egozispecial
10/29/2025FinalRobert Stahlprogress
10/28/2025FinalRobert Stahlprogress
10/23/2025Maintenance informationRonald Merhigeenergy_progress
10/23/2025HVAC-R and service water heating equipmentRonald Merhigeenergy_progress
10/23/2025HVAC-R and service water piping design and insulationRonald Merhigeenergy_progress
10/23/2025HVAC-R and service water piping design and insulationRonald Merhigeenergy_progress
10/23/2025Energy Code Compliance InspectionsRonald Merhigeprogress
10/23/2025Maintenance informationRonald Merhigeenergy_progress
10/23/2025HVAC-R and service water piping design and insulationRonald Merhigeenergy_progress
10/23/2025HVAC-R and service water heating equipmentRonald Merhigeenergy_progress
10/23/2025Tenant Protection Plan ComplianceRonald Merhigespecial
10/23/2025Interior lighting powerFrank Caminitienergy_progress
10/23/2025Lighting controlsFrank Caminitienergy_progress
10/23/2025Fire-Resistant Penetrations and JointsRonald Merhigespecial
10/23/2025Energy Code Compliance InspectionsRonald Merhigeprogress
10/22/2025Tenant Protection Plan ComplianceRonald Merhigespecial
10/15/2025FinalRonald Merhigeprogress
10/15/2025Tenant Protection Plan ComplianceRonald Merhigespecial
10/15/2025Energy Code Compliance InspectionsRonald Merhigeprogress
10/15/2025Fire-Resistant Penetrations and JointsRonald Merhigespecial
10/15/2025Mechanical SystemsRonald Merhigespecial
10/10/2025FinalRobert Stahlprogress
Latest 25 of 26.
▾Documents — 116 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/28/2026B08002477-P1Request digital key ↗
08/28/2026B08002477-I1Request digital key ↗
08/24/2026B01087580-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸Applications & Permits17
▸BISWORK PERMIT APPLICATION7
05/10/2013320469532Open ↗
02/01/2013320533160Open ↗
01/23/2013320533160Open ↗
Showing 3 of 7 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
09/25/2017321658014Open ↗
08/09/2012320533160Open ↗
04/30/2012320469532Open ↗
Showing 3 of 4 on file for this type
▸BISPLACE OF ASSEMBLY4
09/27/2016320276820Open ↗
05/04/2016320276820Open ↗
09/19/2013320276820Open ↗
Showing 3 of 4 on file for this type
▸BISPLACE OF ASSEMBLY APPLICATION2
06/27/2014320276820Open ↗
04/28/2014320276820Open ↗
▸Seals & Professional Certifications38
▸DOB NOWProgress Inspector Seal & Signature11
09/27/2026B01306059-I1Open ↗
09/27/2026B01306059-I1Open ↗
09/02/2026B01303094-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
09/25/2017321658014Open ↗
02/02/2015320276820Open ↗
08/09/2012320533160Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/28/2026B08002477-I1Open ↗
08/28/2026B08002477-P1Open ↗
08/20/2026B01303094-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/27/2026B01306059-I1Open ↗
09/27/2026B01306059-I1Open ↗
09/02/2026B01303094-I1Open ↗
Showing 3 of 7 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
09/25/2017321658014Open ↗
11/06/2009320092715Open ↗
▸BISProfessional and Owner Certification (POC3)1
09/25/2017321658014Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
11/06/2009320092715Open ↗
▸Trade Schedules & Equipment3
▸BISSELF-CERT PLUMBING NOTICE2
05/09/2013320533160Open ↗
03/08/2013320533160Open ↗
▸BISSCHEDULE B - PLUMBING1
08/09/2012320533160Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/28/2026B08002477-P1Open ↗
08/28/2026B08002477-I1Open ↗
08/20/2026B01303094-S1Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
06/01/2011320276820Open ↗
11/06/2009320092715Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
09/25/2017321658014Open ↗
08/09/2012320533160Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
04/30/2012320469532Open ↗
▸Energy Compliance5
▸BISAS-BUILT ENERGY ANALYSIS2
06/30/2015320469532Open ↗
01/06/2015320533160Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
08/09/2012320533160Open ↗
▸BISTR8: Energy Code Progress Inspections1
05/15/2012320469532Open ↗
▸BISEMERGENCY LIGHTING (IF NOT IN COMPLIANCE WITH MEMEO 2-18-81)1
02/02/2015320276820Open ↗
▸Approvals, Objections & Sign-offs16
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter6
08/13/2026B01301001-I1Open ↗
08/13/2026B08002477-P1Open ↗
08/13/2026B01303094-S1Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS3
08/09/2012320533160Open ↗
04/30/2012320469532Open ↗
11/06/2009320092715Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
06/30/2015320469532Open ↗
03/07/2015320092715Open ↗
01/06/2015320533160Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION2
09/02/2016320276820Open ↗
03/07/2015320092715Open ↗
▸BISFLAME SPREAD/FIRE LETTER1
02/02/2015320276820Open ↗
▸BISCCD1-Construction Code Determination1
06/15/2012320469532Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT5
09/25/2017321658014Open ↗
06/30/2015320469532Open ↗
01/06/2015320533160Open ↗
Showing 3 of 5 on file for this type
▸Filing & Intake Forms8
▸BISEFILING COVER SHEET4
09/25/2017321658014Open ↗
08/09/2012320533160Open ↗
04/30/2012320469532Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION4
12/15/2014320533160Open ↗
01/31/2014320276820Open ↗
09/19/2013320276820Open ↗
Showing 3 of 4 on file for this type
▸Other Documents5
▸DOB NOWCalculations2
08/13/2026B01363874-I1Open ↗
08/13/2026B01087580-I1Open ↗
▸DOB NOWManufacturer's Specifications2
08/13/2026B01087580-I1Open ↗
08/13/2026B01363874-I1Open ↗
▸BISOP-4 - Special Report1