← Back
One story - permanent living quarter
141-10 SOUTH DRIVE
QUEENS · BIN 4101085
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R1-2Zoning
2,100 sfGross Floor Area
1Units
0 Open Violations
One story - permanent living quarter · 6,600 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
1 job · most recent 05/19/2025
FiledStatusContractorScope
05/19/2025CompleteREDLINE ELECTRIC INC1 meters
Building Lifecycle
All (13)Filed (2)Permit Issued (1)Signed Off (1)Violation (1)Special Inspection (8)
02/26/2026
Signed off — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01186569-I1
02/19/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
02/19/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
02/19/2026
Special inspection requirement — Final
Ayracon Almaraz
02/19/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
01/20/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01186569-P1
01/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
01/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
01/20/2026
Special inspection requirement — Final
Ayracon Almaraz
01/20/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
11/25/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/04/2025
Permit issued — Solar
Q01186569-I1-SL
02/26/2025
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01186569-I1
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/08/2024$1.4M—Private party → Private party$643/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC201/20/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036201/20/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTRINITY SOLAR LLC03/04/2025
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
02/19/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
02/19/2026Energy Code Compliance InspectionsAyracon Almarazprogress
02/19/2026FinalAyracon Almarazprogress
02/19/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
01/20/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
01/20/2026Energy Code Compliance InspectionsAyracon Almarazprogress
01/20/2026FinalAyracon Almarazprogress
01/20/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026Q01186569-I1Request digital key ↗
08/17/2026Q01186569-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature6
09/23/2026Q01186569-P1Open ↗
09/23/2026Q01186569-P1Open ↗
09/23/2026Q01186569-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026Q01186569-I1Open ↗
08/17/2026Q01186569-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026Q01186569-P1Open ↗
08/28/2026Q01186569-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026Q01186569-P1Open ↗
08/17/2026Q01186569-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01186569-I1Open ↗