← Back
Two family brick
141 BERKELEY PLACE
BROOKLYN · BIN 3019652
💬 Discuss this project
1888Year Built
3Stories
B1Building Class
R6BZoning
3,378 sfGross Floor Area
2Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Two family brick · 1,667 sf lot · 2.03 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Floor 317p · 1 filing · 20 docs
Floor 218p · 1 filing · 20 docs
Floor 120p · 1 filing · 20 docs
Cellar18p · 1 filing · 20 docs
Basement16p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
141 BEREKELEY PLACE CO203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/05/2021$2.8M—FORMANCO ALPHA LLC → Private party$821/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KONOSKI ENGINEERING PLLC1108/29/2025
ARCHITECTURE+CONSTRUCTION, PLLC305/21/2025
NY BUILDING ASSOCIATES INC101/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ANZALONE ARCHITECTURE2803/21/2026
BROOKLYN SOLARWORKS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ARTUR KALAJGeneral Contractor207/08/2026
BROOKLYN SOLARWORKS LLCGeneral Contractor203/21/2026
AQUEDUCT MECHANICAL CORPFire Protection107/08/2026
AQUEDUCT MECHANICAL CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KONOSKI ENGINEERING PLLC91111108/29/2025
ARCHITECTURE+CONSTRUCTION1326305/21/2025
NKM ENGINEERING PLLC6244101/21/2025
Building Lifecycle
All (101)Filed (15)Permit Issued (5)Signed Off (4)Violation (22)Inspection (13)Objection (12)Special Inspection (30)
05/01/2026
Violation issued (HPD, open)
A
11/19/2025
Violation issued (HPD, open)
I
09/26/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/09/2025
Signed off — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-S2
09/02/2025
Special inspection requirement — HVAC-R and service water heating equipment
christopher konoski
09/02/2025
Special inspection requirement — Energy Code Compliance Inspections
christopher konoski
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
christopher konoski
09/02/2025
Special inspection requirement — Maintenance information
christopher konoski
09/02/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
christopher konoski
09/02/2025
Special inspection requirement — HVAC-R and service water heating system controls
christopher konoski
08/29/2025
Signed off — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-S1
08/29/2025
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-A1
07/21/2025
Signed off — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-S3
06/16/2025
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P8
05/21/2025
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P9
05/13/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/07/2025
Special inspection requirement — Fenestration areas
Joshua Pulver
05/07/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
Joshua Pulver
05/07/2025
Special inspection requirement — Fenestration air leakage
Joshua Pulver
05/07/2025
Special inspection requirement — Fire-Resistance Rated Construction
Joshua Pulver
05/07/2025
Special inspection requirement — Lighting in dwelling units
Joshua Pulver
05/07/2025
Special inspection requirement — Insulation placement and R values
Joshua Pulver
05/07/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Joshua Pulver
05/07/2025
Special inspection requirement — Permanent certificate
Joshua Pulver
05/07/2025
Special inspection requirement — Air barrier - visual inspection
Joshua Pulver
05/07/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joshua Pulver
05/07/2025
Special inspection requirement — Metering
Joshua Pulver
05/07/2025
Special inspection requirement — Energy Code Compliance Inspections
Joshua Pulver
04/16/2025
Signed off — Alteration
INSTALLATION OF SOLAR PV SYSTEM. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
B01167299-I1
04/10/2025
Inspection — Certified Storm Drainage-ST-Fixtures-Finish
Certified
View inspection ↗
01/23/2025
Permit issued — Solar
B01167299-I1-SL
01/21/2025
Filed — Alteration
INSTALLATION OF SOLAR PV SYSTEM. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
B01167299-I1
01/15/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/15/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
01/15/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
NARESH MAHANGU
01/15/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
NARESH MAHANGU
01/15/2025
Special inspection requirement — Final
NARESH MAHANGU
01/15/2025
Special inspection requirement — Air barrier - visual inspection
NARESH MAHANGU
01/15/2025
Special inspection requirement — Energy Code Compliance Inspections
NARESH MAHANGU
11/27/2024
Violation issued (HPD, closed)
I
10/23/2024
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/23/2024
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/23/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
10/04/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/29/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P7
09/19/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
christopher konoski
09/19/2024
Special inspection requirement — Shutoff dampers
christopher konoski
09/19/2024
Special inspection requirement — Mechanical Systems
christopher konoski
09/19/2024
Special inspection requirement — HVAC-R and service water heating equipment
christopher konoski
09/19/2024
Special inspection requirement — Maintenance information
christopher konoski
09/19/2024
Special inspection requirement — Sprinkler Systems
christopher konoski
09/19/2024
Special inspection requirement — HVAC-R and service water heating system controls
christopher konoski
09/18/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P5
09/18/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P6
09/13/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P1
09/13/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P2
09/12/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P4
09/11/2024
Filed — Alteration CO
SPRINKLER WORK FILED IN CONJUNCTION WITH BUILDING RENOVATION FOR 2 FAMILY RESIDENCE. FULLY SPRINKLER THE BUILDING. INSTALL SPRINKLER HEADS AND PIPING PER PLANS. COMBINED WATER SERVICE FILED UNDER SUBSEQUENT PL APPLICATION B01009964-S2.
B01009964-P3
08/13/2024
Permit issued — Plumbing
B01009964-S2-PL
Latest 60 of 101 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offBROOKLYN SOLARWORKS LLC01/23/2025
DOB NOWPlumbingSigned-offAQUEDUCT MECHANICAL CORP08/13/2024
DOB NOWSprinklersSigned-offAQUEDUCT MECHANICAL CORP07/22/2024
DOB NOWGeneral ConstructionPermit IssuedARTUR KALAJ07/11/2024
DOB NOWMechanical SystemsSigned-offARTUR KALAJ07/03/2024
BISPLISSUEDTAVELLA PLBG & HTG CORP03/09/2011
BIS—ISSUEDTHREE STAR CONSTRUCTION C03/03/2011
BISPLISSUEDREGIONAL SCAFFOLD & HOISTING CO.09/30/1993
BIS—ISSUEDVICTOR CONST. & STEEL CORP.09/01/1993
1 project · most recent 08/29/2025
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/29/2025Permit IssuedARTUR KALAJAir Conditioning Systems, Ventilation Systems
Cooling
Mitsubishi Electric MXZ-SM48NAMHZ2-U1 4 tons · Condensing Unit ×6
Ventilation
Panasonic FV-05-11VK1 80 CFM · Exhaust Fan ×15
Fantech DBF-4XL 150 CFM · Exhaust Fan ×3
1 project · most recent 08/29/2025
FiledStatusContractorScope
08/29/2025Signed-offAQUEDUCT MECHANICAL CORP92 heads
1 project · most recent 08/29/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/29/2025Signed-offPEGASUS P&H CORPGas, Storm, Water/Sanitary
2 projects · most recent 01/15/2025
FiledStatusContractorScope
01/15/2025CompleteBROOKYLN SOLARWORKS, LLC—
07/18/2024CompleteTITANIUM ELECTRICAL CORP3 meters
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
09/26/2025Pass-Final CND-Occupancy InspectionPassView ↗
04/10/2025Certified Storm Drainage-ST-Fixtures-FinishCertifiedView ↗
01/15/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/15/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/23/2024Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/23/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/23/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/23/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
10/04/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/28/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/09/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
02/06/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 71
DateRequirementInspectorRole
09/02/2025HVAC-R and service water heating equipmentchristopher konoskienergy_progress
09/02/2025HVAC-R and service water heating system controlschristopher konoskienergy_progress
09/02/2025HVAC-R and service water piping design and insulationchristopher konoskienergy_progress
09/02/2025Energy Code Compliance Inspectionschristopher konoskiprogress
09/02/2025Fire-Resistant Penetrations and Jointschristopher konoskispecial
09/02/2025Maintenance informationchristopher konoskienergy_progress
05/07/2025Air barrier - visual inspectionJoshua Pulverenergy_progress
05/07/2025MeteringJoshua Pulverenergy_progress
05/07/2025Fenestration air leakageJoshua Pulverenergy_progress
05/07/2025Insulation placement and R valuesJoshua Pulverenergy_progress
05/07/2025Fenestration and door U-factor and product ratingsJoshua Pulverenergy_progress
05/07/2025Fenestration areasJoshua Pulverenergy_progress
05/07/2025Permanent certificateJoshua Pulverenergy_progress
05/07/2025Fire-Resistant Penetrations and JointsJoshua Pulverspecial
05/07/2025Structural Stability – Alterations of existing buildingsJoshua Pulverspecial
05/07/2025Energy Code Compliance InspectionsJoshua Pulverprogress
05/07/2025Fire-Resistance Rated ConstructionJoshua Pulverprogress
05/07/2025Lighting in dwelling unitsJoshua Pulverenergy_progress
01/15/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
01/15/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
01/15/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
01/15/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
01/15/2025FinalNARESH MAHANGUprogress
09/19/2024Ventilation and air distribution systemchristopher konoskienergy_progress
09/19/2024HVAC-R and service water heating system controlschristopher konoskienergy_progress
Latest 25 of 71.
▾Documents — 130 on file (BIS + DOB NOW)
▸Plans & Drawings15
▸DOB NOWPlans/Sketch15
08/23/2026B01167299-I1Request digital key ↗
08/21/2026B01009964-S3Request digital key ↗
08/21/2026B01009964-S1Request digital key ↗
Showing 3 of 15 on file for this type
▸Applications & Permits18
▸DOB NOWLPC Approval/Permit12
08/13/2026B01167299-I1Open ↗
08/13/2026B01009964-P8Open ↗
08/13/2026B01009964-P7Open ↗
Showing 3 of 12 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION3
10/25/2011320272423Open ↗
05/23/2011320272423Open ↗
02/15/2011320272423Open ↗
▸BISWORK PERMIT APPLICATION2
03/15/2011320272423Open ↗
03/04/2011320272423Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
05/19/2011320272423Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B01009964-I1Open ↗
▸Seals & Professional Certifications52
▸DOB NOWProgress Inspector Seal & Signature20
09/01/2026B01009964-P4Open ↗
09/01/2026B01009964-P4Open ↗
09/01/2026B01009964-P4Open ↗
Showing 3 of 20 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature15
08/21/2026B01009964-S3Open ↗
08/21/2026B01009964-S2Open ↗
08/21/2026B01009964-S1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
09/25/2026B01009964-P5Open ↗
09/01/2026B01009964-P4Open ↗
09/01/2026B01009964-P4Open ↗
Showing 3 of 12 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY-CERTIFICATION3
12/01/2012320272423Open ↗
12/01/2012320272423Open ↗
02/15/2011320272423Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/15/2011320272423Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
02/15/2011320272423Open ↗
▸Trade Schedules & Equipment5
▸BISSCHEDULE B - PLUMBING3
10/25/2011320272423Open ↗
05/23/2011320272423Open ↗
02/15/2011320272423Open ↗
▸BISSELF-CERT PLUMBING NOTICE2
12/16/2011320272423Open ↗
04/18/2011320272423Open ↗
▸Safety & Tenant Protection5
▸DOB NOWStreet Tree Checklist3
08/13/2026B01009964-P9Open ↗
08/13/2026B01009964-P4Open ↗
08/13/2026B01009964-I1Open ↗
▸BISSTREET TREE CHECKLIST1
02/15/2011320272423Open ↗
▸BISST-1 Street Tree Checklist1
02/22/2011320272423Open ↗
▸Environmental & Asbestos17
▸DOB NOWDEP ACP-5: Asbestos Assessment Report15
08/21/2026B01009964-S3Open ↗
08/21/2026B01009964-S2Open ↗
08/21/2026B01009964-S1Open ↗
Showing 3 of 15 on file for this type
▸BISTHIS IS NOT AN ASBESTOS PROJECT2
02/22/2011320272423Open ↗
02/15/2011320272423Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY - LOC: REQUEST2
12/27/2012320272423Open ↗
12/10/2012320272423Open ↗
▸BISLANDMARKS APPROVAL1
12/01/2012320272423Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/15/2011320272423Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/01/2012320272423Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
02/15/2011320272423Open ↗
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01167299-I1Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/01/2012320272423Open ↗
02/15/2011320272423Open ↗
▸Filing & Intake Forms3
▸BISADDITIONAL INFORMATION2
12/01/2012320272423Open ↗
02/22/2011320272423Open ↗
▸BISEFILING COVER SHEET1
02/15/2011320272423Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification3
08/21/2026B01009964-I1Open ↗
08/21/2026B01009964-P9Open ↗
08/21/2026B01009964-P4Open ↗
▸BISPLOT DIAGRAM1
02/15/2011320272423Open ↗
▸DOB NOWFinal Survey1
08/13/2026B01009964-I1Open ↗