← Back
Banking facility, with or without parking
1415 AVENUE Z
💬 Discuss this project
1971Year Built
2Stories
K7Building Class
C4-2Zoning
5,059 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Banking facility, with or without parking · Owner of record: FLEET BANK OF NEW YORK NAT ASSOC · 13,760 sf lot · 0.37 FAR built · Flood zone X500
Locations of Work
ArchitectureMechanical
Permit Issued — active, not yet Signed-off
Roof1p · 1 filing · 2 docs
Floor 2Under Construction2p · 1 filing · 15 docs
Floor 110p · 3 filings · 18 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FLEET BANK303/21/2026
BANK OF AMERICA503/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MP DESIGN AND CONSTRUCTION1203/21/2026
PROJECT EXPEDITERS CONSULTING CO.203/21/2026
KAZAM CONSULTANTS403/21/2026
WHIDDEN SILVER203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VARIANT SERVICES INCGeneral Contractor607/08/2026
CLUNE CONSTRUCTION CO LPGeneral Contractor303/21/2026
NATIONAL MAINTENANCEScaffold207/08/2026
BNF CONTRACTORS INCGeneral Contractor203/21/2026
EMCOR SERVICES NY/NJ INCGeneral Contractor107/08/2026
J. CAIAZZO PLBG & HTG CORPlumbing108/27/2026
SCHMELZ BROS., INCPlumbing107/08/2026
LENS ELECTRIC, INCElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TRIANGLE INSPECTION & TES7495103/03/2023
CONCESSI ENGINEERING, P.C540201/28/2023
KATZ ENGINEERING238108/09/2019
Building Lifecycle
All (67)Filed (13)Permit Issued (11)Signed Off (10)Violation (14)Objection (5)Special Inspection (14)
08/26/2026
Permit issued — Boiler Equipment
B01347053-S3-BE
08/20/2026
Filed — Alteration CO
Boiler replacement as shown in the drawings filed herewith and superseding DOB job #301443971.
B01347053-S3
05/27/2026
Special inspection requirement — Maintenance information
Robert Concessi
05/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
Robert Concessi
05/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Robert Concessi
05/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Concessi
05/06/2026
Signed off — Alteration
replace existing rooftop condensing units with same in same location
B00833444-I1
04/22/2026
Objection raised — Scope
04/22/2026
Objection raised — Zoning
04/22/2026
Objection raised — Zoning
04/22/2026
Objection raised — Zoning
04/22/2026
Objection raised — Zoning
04/15/2026
Filed — Alteration CO
Boiler replacement as shown in the drawings filed herewith and superseding DOB job #301443971.
B01347053-I1
07/11/2025
Signed off — Alteration
INTERIOR RENOVATION OF FINANCIAL CENTER: FINiSHES AND FURNITURES & PARTITION WALLS. NO CHANGE TO THE EXISTING OCCUPANCY TYPE, OCCUPANT LOAD, MEANS OFEGRESS OR LIFE SAFETY SYSTEMS.
B01098655-I1
02/11/2025
Permit issued — General Construction
B01098655-I1-GC
02/06/2025
Filed — Alteration
INTERIOR RENOVATION OF FINANCIAL CENTER: FINiSHES AND FURNITURES & PARTITION WALLS. NO CHANGE TO THE EXISTING OCCUPANCY TYPE, OCCUPANT LOAD, MEANS OFEGRESS OR LIFE SAFETY SYSTEMS.
B01098655-I1
11/07/2024
Signed off — Alteration
Replace existing after hour depository with a ADA compliant after hour depository. No change to use, egress or occupancy.
B01018779-I1
05/08/2024
Permit issued — General Construction
B01018779-I1-GC
05/03/2024
Filed — Alteration
Replace existing after hour depository with a ADA compliant after hour depository. No change to use, egress or occupancy.
B01018779-I1
03/12/2024
Special inspection requirement — Final
JASON COATS
03/09/2023
Permit issued — Mechanical Systems
B00833444-I1-MS
03/03/2023
Filed — Alteration
replace existing rooftop condensing units with same in same location
B00833444-I1
02/02/2023
Signed off — Alteration
REVISIONS TO MECHANICAL SYSTEM AS PER INSTALLATION OF NEW ATM IN EXISTING BANK. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B00611508-I1
01/30/2023
Special inspection requirement — Maintenance information
Robert Concessi
01/30/2023
Special inspection requirement — HVAC-R and service water heating equipment
Robert Concessi
01/30/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Robert Concessi
01/30/2023
Special inspection requirement — Mechanical Systems
Robert Concessi
01/30/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Robert Concessi
01/30/2023
Special inspection requirement — Final
Robert Concessi
01/30/2023
Special inspection requirement — HVAC-R and service water heating system controls
Robert Concessi
01/28/2023
Filed — Alteration
REVISIONS TO MECHANICAL SYSTEM AS PER INSTALLATION OF NEW ATM IN EXISTING BANK. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B00611508-P1
01/24/2023
Signed off — Alteration
Erect illuminated accessory business wall sign; copy reading "Bank of America with Logo"
B00785933-I1
01/24/2023
Signed off — Alteration
Erect illuminated accessory business wall sign; copy reading "Bank of America with Logo"
B00785937-I1
08/23/2022
Filed — Alteration
Erect illuminated accessory business wall sign; copy reading "Bank of America with Logo"
B00785933-I1
08/23/2022
Filed — Alteration
Erect illuminated accessory business wall sign; copy reading "Bank of America with Logo"
B00785937-I1
08/23/2022
Permit issued — Sign
B00785933-I1-SG
08/23/2022
Permit issued — Sign
B00785937-I1-SG
08/23/2022
Special inspection requirement — Final
JERE MURDOCH
08/23/2022
Special inspection requirement — Final
JERE MURDOCH
07/07/2022
Signed off — Alteration
Removal and replacement of asphalt and concrete in existing drive thru. Asphalt repair for installation of post of additional Security lighting.
B00660668-I1
06/28/2022
Signed off — Alteration
B00607273-I1
02/17/2022
Permit issued — General Construction
B00660668-I1-GC
02/11/2022
Filed — Alteration
Removal and replacement of asphalt and concrete in existing drive thru. Asphalt repair for installation of post of additional Security lighting.
B00660668-I1
02/03/2022
Permit issued — Mechanical Systems
B00611508-I1-MS
02/02/2022
Permit issued — General Construction
B00607273-I1-GC
01/20/2022
Filed — Alteration
REVISIONS TO MECHANICAL SYSTEM AS PER INSTALLATION OF NEW ATM IN EXISTING BANK. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B00611508-I1
01/20/2022
Filed — Alteration
B00607273-I1
10/06/2020
Signed off — Alteration
B00191578-I1
10/06/2020
Signed off — Alteration
B00191593-I1
09/17/2019
Permit issued — Plumbing
B00191593-I1-PL
09/12/2019
Permit issued — Mechanical Systems
B00191578-I1-MS
08/09/2019
Filed — Alteration
B00191578-I1
08/09/2019
Filed — Alteration
B00191593-I1
05/15/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/01/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/13/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/31/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/01/2009
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 67 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWBoiler EquipmentPermit IssuedJ. CAIAZZO PLBG & HTG COR08/26/2026
DOB NOWGeneral ConstructionSigned-offVARIANT SERVICES INC02/11/2025
DOB NOWGeneral ConstructionSigned-offCLUNE CONSTRUCTION CO LP05/08/2024
DOB NOWMechanical SystemsSigned-offEMCOR SERVICES NY/NJ INC03/09/2023
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC08/23/2022
DOB NOWSignSigned-offNATIONAL MAINTENANCE, INC08/23/2022
DOB NOWGeneral ConstructionSigned-offVARIANT SERVICES INC02/17/2022
DOB NOWMechanical SystemsSigned-offVARIANT SERVICES INC02/03/2022
DOB NOWGeneral ConstructionSigned-offVARIANT SERVICES INC02/02/2022
DOB NOWPlumbingSigned-offSCHMELZ BROS., INC09/17/2019
DOB NOWMechanical SystemsSigned-offBNF CONTRACTORS INC09/12/2019
BISOTISSUEDWADE RAY & ASSOC CONST IN04/03/2019
BISOTISSUEDBNF CONTRACTORS INC07/03/2014
BIS—ISSUEDNATIONAL MAINTENANCE, INC.08/02/2004
BISPLISSUEDSTEPHEN FOX P & H INC05/06/2004
BISBLISSUEDSTEPHEN FOX P & H INC05/06/2004
BISOTISSUEDSTEPHEN FOX PLBG & HTG INC04/20/2004
BIS—ISSUEDNORTH SHORE NEON SIGN CO., INC.05/14/2001
BIS—ISSUEDSERVICE SIGN ERECTORS07/02/1992
7 projects · most recent 10/19/2023
General Wiring
FiledStatusContractorScope
10/19/2023CompleteLENS ELECTRIC, INC—
10/19/2023CompleteLENS ELECTRIC, INC—
10/27/2022Permit IssuedNATIONAL MAINT. INC—
10/27/2022Permit IssuedNATIONAL MAINT. INC—
03/17/2022Permit IssuedT. DIRUSSO ELEC'L CONT INGeneral Wiring
10/18/2019CompleteALL NU ELEC'L CONTR'G CORGeneral Wiring
05/14/2019CompleteJAMES F. VOLPE ELEC'LGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
05/27/2026Maintenance informationRobert Concessienergy_progress
05/27/2026HVAC-R and service water heating system controlsRobert Concessienergy_progress
05/27/2026HVAC-R and service water heating equipmentRobert Concessienergy_progress
05/27/2026HVAC-R and service water piping design and insulationRobert Concessienergy_progress
03/12/2024FinalJASON COATSprogress
01/30/2023Maintenance informationRobert Concessienergy_progress
01/30/2023HVAC-R and service water heating equipmentRobert Concessienergy_progress
01/30/2023HVAC-R and service water piping design and insulationRobert Concessienergy_progress
01/30/2023Mechanical SystemsRobert Concessispecial
01/30/2023Fire-Resistant Penetrations and JointsRobert Concessispecial
01/30/2023FinalRobert Concessiprogress
01/30/2023HVAC-R and service water heating system controlsRobert Concessienergy_progress
08/23/2022FinalJERE MURDOCHprogress
08/23/2022FinalJERE MURDOCHprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Bank of AmericaRetailFloor 1
Project B00607273 Alteration · LOC Issued · 01/20/2022
Project B00611508 Alteration · LOC Issued · 01/20/2022
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 117 on file (BIS + DOB NOW)
▸Plans & Drawings14
▸DOB NOWPlans/Sketch12
09/03/2026B01347053-S3Request digital key ↗
08/31/2026B00607273-I1Request digital key ↗
08/31/2026B00611508-P1Request digital key ↗
Showing 3 of 12 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/02/2026B00191578-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
09/02/2026B00191593-I1Request digital key ↗
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION4
02/19/2020301443971Open ↗
08/09/2019340688759Open ↗
03/25/2019321936161Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION3
09/12/2019340688759Open ↗
04/05/2019321936161Open ↗
07/23/2014320996981Open ↗
▸DOB NOWState DEC Permit1
08/13/2026B00191593-I1Open ↗
▸Seals & Professional Certifications45
▸DOB NOWDPL-1: Design Professional Seal & Signature14
09/03/2026B01347053-S3Open ↗
08/31/2026B00607273-I1Open ↗
08/31/2026B00611508-P1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWProgress Inspector Seal & Signature13
09/27/2026B00611508-I1Open ↗
09/27/2026B00611508-I1Open ↗
09/07/2026B01347053-S3Open ↗
Showing 3 of 13 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION10
02/21/2020340688759Open ↗
07/26/2019321936161Open ↗
07/26/2019321936161Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/27/2026B00611508-I1Open ↗
09/27/2026B00611508-I1Open ↗
09/02/2026B01347053-S1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT2
08/09/2019340688759Open ↗
03/28/2019321936161Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
08/09/2019340688759Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
08/09/2019340688759Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
03/28/2019321936161Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B01347053-I1Open ↗
▸Environmental & Asbestos14
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/31/2026B00607273-I1Open ↗
08/31/2026B00611508-P1Open ↗
08/31/2026B00611508-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form3
08/13/2026B00191578-I1Open ↗
08/13/2026B01098655-I1Open ↗
08/13/2026B00191593-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
03/28/2019321936161Open ↗
07/11/2014320996981Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
08/09/2019340688759Open ↗
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
08/09/2019340688759Open ↗
▸Energy Compliance15
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS8
07/26/2019321936161Open ↗
07/26/2019321936161Open ↗
03/28/2019321936161Open ↗
Showing 3 of 8 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS3
02/21/2020340688759Open ↗
07/26/2019321936161Open ↗
11/25/2014320996981Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
08/09/2019340688759Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
08/09/2019340688759Open ↗
▸BISNYCECC ANALYSIS1
08/09/2019340688759Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/31/2026B00611508-I1Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
08/09/2019340688759Open ↗
▸Approvals, Objections & Sign-offs7
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST3
02/21/2020340688759Open ↗
07/26/2019321936161Open ↗
11/25/2014320996981Open ↗
▸DOB NOWDEP Variance (V5) letter2
08/13/2026B00191578-I1Open ↗
08/13/2026B00191593-I1Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
07/11/2014320996981Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
11/25/2014320996981Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT6
02/21/2020340688759Open ↗
08/09/2019340688759Open ↗
07/26/2019321936161Open ↗
Showing 3 of 6 on file for this type
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET2
03/21/2019321936161Open ↗
07/11/2014320996981Open ↗
▸BISBOROUGH INTAKE FORM2
02/21/2020340688759Open ↗
07/26/2019321936161Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
08/09/2019340688759Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/17/2026B01347053-I1Open ↗