← Back
Two family converted from one family
142-43 249 STREET
QUEENS · BIN 4288613
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R3XZoning
1,860 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 6,000 sf lot · 0.31 FAR built · Flood zone X500
Locations of Work
Architecture
Cellar2p · 1 filing · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/29/2019$620K—MANSION TWO LLC → Private party$333/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RCGA ARCHITECTS, P.C207/01/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
RCGA ARCHITECTS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MARTINEZ ELECTRICAL CONTElectrical103/22/2026
DNS PLUMBING & HEATING COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ASHWANI KHANNA PE5256107/01/2024
Building Lifecycle
All (18)Filed (2)Permit Issued (1)Violation (1)Inspection (3)Objection (6)Special Inspection (5)
09/29/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
09/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/04/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/14/2024
Permit issued — Plumbing
Q01035557-S1-PL
07/31/2024
Objection resolved — Addressed
07/20/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ASHWANI KHANNA
07/20/2024
Special inspection requirement — Energy Code Compliance Inspections
ASHWANI KHANNA
07/11/2024
Objection raised — Inspections
07/01/2024
Filed — Alteration
Installation of Combination boiler at the Boiler room in the cellar. No change in the USE, Egress and Occupancy. Plumbing Work filed separately.
Q01035557-S1
06/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
06/03/2024
Special inspection requirement — Energy Code Compliance Inspections
05/30/2024
Objection raised — Inspections
05/30/2024
Objection resolved — Addressed
05/30/2024
Objection raised — Other
05/30/2024
Objection resolved — Addressed
05/21/2024
Filed — Alteration
Installation of Combination boiler at the Boiler room in the cellar. No change in the USE, Egress and Occupancy. Plumbing Work filed separately.
Q01035557-I1
05/15/2024
Special inspection requirement — Final
05/11/2012
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDNS PLUMBING & HEATING CO08/14/2024
BISEQISSUEDUNIVERSAL DESIGN DEV12/06/2006
BIS—ISSUEDUNIVERSAL DESIGN DEV12/06/2006
1 project · most recent 07/01/2024
Gas
FiledStatusContractorScope
07/01/2024Signed-offDANIEL SKRELAGas
1 project · most recent 07/27/2024
General Wiring
FiledStatusContractorScope
07/27/2024Permit IssuedMARTINEZ ELECTRICAL CONTGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
09/29/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
09/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/04/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/20/2024Fire-Resistant Penetrations and JointsASHWANI KHANNAspecial
07/20/2024Energy Code Compliance InspectionsASHWANI KHANNAprogress
06/03/2024Fire-Resistant Penetrations and Joints—special
06/03/2024Energy Code Compliance Inspections—progress
05/15/2024Final—progress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/22/2026Q01035557-S1Request digital key ↗
08/22/2026Q01035557-I1Request digital key ↗
▸Applications & Permits3
▸BISPLAN / WORK APPROVAL APPLICATION2
11/27/2018402476682Open ↗
10/09/2018402476682Open ↗
▸BISApplication Withdrawal/Address Change Form OP-1131
11/27/2018402476682Open ↗
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/22/2026Q01035557-S1Open ↗
08/22/2026Q01035557-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/28/2026Q01035557-S1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q01035557-S1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/22/2026Q01035557-I1Open ↗
08/22/2026Q01035557-S1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/24/2018402476682Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
11/27/2018402476682Open ↗
▸BISBOROUGH INTAKE FORM1
10/09/2018402476682Open ↗