← Back
Two family frame
1426 80 STREET
BROOKLYN · Bensonhurst · BIN 3349521
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R4Zoning
1,296 sfGross Floor Area
2Units
Two family frame · 2,633 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Cellar3p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NEW AGE ENGINEERING PLLC409/05/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VIGILANTE CONTRACTING COGeneral Contractor107/08/2026
VIGILANTE CONTRACTING COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NEW AGE ENGINEERING PLLC7746409/05/2023
Building Lifecycle
All (20)Filed (4)Permit Issued (2)Signed Off (2)Inspection (2)Special Inspection (10)
09/29/2023
Signed off — Alteration
INSTALL REPLACEMENT BOILER, NEW HOT WATER HEATER, REPLACEMENT GAS METER, AND REPLACEMENT GAS PIPING AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812830-I1
09/29/2023
Signed off — Alteration
INSTALL NEW EXHAUST VENT FOR REPLACEMENT HOT WATER HEATER AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812843-I1
09/07/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/05/2023
Filed — Alteration
INSTALL REPLACEMENT BOILER, NEW HOT WATER HEATER, REPLACEMENT GAS METER, AND REPLACEMENT GAS PIPING AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812830-P2
08/29/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
08/29/2023
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
08/29/2023
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
08/29/2023
Special inspection requirement — Maintenance information
Stephen Shishko
08/29/2023
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
08/24/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/06/2023
Filed — Alteration
INSTALL REPLACEMENT BOILER, NEW HOT WATER HEATER, REPLACEMENT GAS METER, AND REPLACEMENT GAS PIPING AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812830-P1
06/05/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Stephen Shishko
06/05/2023
Special inspection requirement — Energy Code Compliance Inspections
Stephen Shishko
06/05/2023
Special inspection requirement — Maintenance information
Stephen Shishko
06/05/2023
Special inspection requirement — HVAC-R and service water heating system controls
Stephen Shishko
06/05/2023
Special inspection requirement — HVAC-R and service water heating equipment
Stephen Shishko
01/27/2023
Filed — Alteration
INSTALL REPLACEMENT BOILER, NEW HOT WATER HEATER, REPLACEMENT GAS METER, AND REPLACEMENT GAS PIPING AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812830-I1
01/27/2023
Filed — Alteration
INSTALL NEW EXHAUST VENT FOR REPLACEMENT HOT WATER HEATER AS PER PLANS. NO CHANGE IN USE, OCCUPANCY, OR EGRESS.
B00812843-I1
01/27/2023
Permit issued — Mechanical Systems
B00812843-I1-MS
01/27/2023
Permit issued — Plumbing
B00812830-I1-PL
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offVIGILANTE CONTRACTING CO01/27/2023
DOB NOWPlumbingSigned-offVIGILANTE CONTRACTING CO01/27/2023
Nothing on file for this building.
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
09/07/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/24/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
08/29/2023Fire-Resistant Penetrations and JointsStephen Shishkospecial
08/29/2023Energy Code Compliance InspectionsStephen Shishkoprogress
08/29/2023HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
08/29/2023Maintenance informationStephen Shishkoenergy_progress
08/29/2023HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
06/05/2023Fire-Resistant Penetrations and JointsStephen Shishkospecial
06/05/2023Energy Code Compliance InspectionsStephen Shishkoprogress
06/05/2023Maintenance informationStephen Shishkoenergy_progress
06/05/2023HVAC-R and service water heating system controlsStephen Shishkoenergy_progress
06/05/2023HVAC-R and service water heating equipmentStephen Shishkoenergy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026B00812843-I1Request digital key ↗
08/27/2026B00812830-P2Request digital key ↗
08/27/2026B00812830-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications14
▸DOB NOWProgress Inspector Seal & Signature8
08/28/2026B00812830-P2Open ↗
08/28/2026B00812830-P2Open ↗
08/28/2026B00812830-P2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/27/2026B00812830-I1Open ↗
08/27/2026B00812830-P1Open ↗
08/27/2026B00812830-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/28/2026B00812830-P2Open ↗
08/25/2026B00812830-P1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/27/2026B00812830-I1Open ↗
08/27/2026B00812830-P1Open ↗
08/27/2026B00812830-P2Open ↗
Showing 3 of 4 on file for this type