← Back
Miscellaneous two family
1433 DEAN STREET
BROOKLYN · Crown Heights (North) · BIN 3030237
💬 Discuss this project
1900Year Built
2Stories
B9Building Class
R6Zoning
2,844 sfGross Floor Area
2Units
Miscellaneous two family · 2,143 sf lot · 1.33 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 21p · 1 filing · 14 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
TOWER803/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/10/2024$2.5M—ADMIRED PROPERTIES LLC → Private party$879/sf building
02/28/2024$1.3M—Private party → ADMIRED PROPERTIES LLC$461/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CQ&J CORPORATION510/10/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
WM ARCH1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MORELL BUILDERS INCGeneral Contractor303/21/2026
WCK ELECTRIC CORP.Electrical103/22/2026
RKA PIPING AND HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781210/02/2024
Building Lifecycle
All (43)Filed (5)Permit Issued (2)Signed Off (2)Inspection (4)Special Inspection (30)
12/20/2024
Signed off — Alteration
EXISTING TWO FAMILY HOUSE WITH PLUMBING WORK AT CELLAR, BASEMENT, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT2 JOB # B01050350-I1. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01061277-I1
11/14/2024
Signed off — Alteration
EXISTING 2 FAMILY BUILDING WITH INTERIOR RENOVATION ON PARTITION AND MECHANICAL WORK ON THE CELLAR, BASEMENT, 1ST, 2ND FLOORS AND OPEN SPACE IN THE REAR. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01050350-I1
11/12/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/11/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
10/11/2024
Special inspection requirement — Maintenance information
CALVIN TRAN
10/11/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
10/11/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
10/11/2024
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
10/10/2024
Filed — Alteration
EXISTING TWO FAMILY HOUSE WITH PLUMBING WORK AT CELLAR, BASEMENT, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT2 JOB # B01050350-I1. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01061277-P2
10/09/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
10/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
10/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
10/09/2024
Special inspection requirement — Maintenance information
CALVIN TRAN
10/09/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
10/03/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
10/03/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
CALVIN TRAN
10/03/2024
Special inspection requirement — Fenestration areas
CALVIN TRAN
10/03/2024
Special inspection requirement — Interior lighting power
CALVIN TRAN
10/03/2024
Special inspection requirement — Maintenance information
CALVIN TRAN
10/03/2024
Special inspection requirement — Metering
CALVIN TRAN
10/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
CHRISTIAN LOZADA
10/03/2024
Special inspection requirement — Fire-Resistance Rated Construction
CALVIN TRAN
10/03/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
10/03/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
10/03/2024
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
10/03/2024
Special inspection requirement — Air barrier - visual inspection
CALVIN TRAN
10/03/2024
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
10/03/2024
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
10/02/2024
Filed — Alteration
EXISTING TWO FAMILY HOUSE WITH PLUMBING WORK AT CELLAR, BASEMENT, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT2 JOB # B01050350-I1. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01061277-P1
10/02/2024
Filed — Alteration
EXISTING 2 FAMILY BUILDING WITH INTERIOR RENOVATION ON PARTITION AND MECHANICAL WORK ON THE CELLAR, BASEMENT, 1ST, 2ND FLOORS AND OPEN SPACE IN THE REAR. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01050350-P1
09/30/2024
Special inspection requirement — HVAC-R and service water heating equipment
CALVIN TRAN
09/30/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
CALVIN TRAN
09/30/2024
Special inspection requirement — Fenestration air leakage
CALVIN TRAN
09/30/2024
Special inspection requirement — HVAC-R and service water heating system controls
CALVIN TRAN
09/30/2024
Special inspection requirement — Insulation placement and R values
CALVIN TRAN
09/30/2024
Special inspection requirement — Energy Code Compliance Inspections
CALVIN TRAN
07/16/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/16/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/16/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/11/2024
Permit issued — General Construction
B01050350-I1-GC
07/08/2024
Filed — Alteration
EXISTING 2 FAMILY BUILDING WITH INTERIOR RENOVATION ON PARTITION AND MECHANICAL WORK ON THE CELLAR, BASEMENT, 1ST, 2ND FLOORS AND OPEN SPACE IN THE REAR. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01050350-I1
06/12/2024
Permit issued — Plumbing
B01061277-I1-PL
06/10/2024
Filed — Alteration
EXISTING TWO FAMILY HOUSE WITH PLUMBING WORK AT CELLAR, BASEMENT, 1ST & 2ND FLOOR IN CONJUNCTION WITH ALT2 JOB # B01050350-I1. NO CHANGE IN USE, MEANS OF EGRESS OR OCCUPANCY.
B01061277-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMORELL BUILDERS INC07/11/2024
DOB NOWPlumbingSigned-offRKA PIPING AND HEATING06/12/2024
1 project · most recent 03/12/2024
General Wiring
FiledStatusContractorScope
03/12/2024Permit IssuedWCK ELECTRIC CORP.General Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/12/2024Pass-Final General Construction Non-Directive 14PassView ↗
07/16/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/16/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/16/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 43
DateRequirementInspectorRole
10/11/2024Energy Code Compliance InspectionsCALVIN TRANprogress
10/11/2024Maintenance informationCALVIN TRANenergy_progress
10/11/2024HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
10/11/2024HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
10/11/2024HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
10/09/2024Energy Code Compliance InspectionsCALVIN TRANprogress
10/09/2024HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
10/09/2024HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
10/09/2024Maintenance informationCALVIN TRANenergy_progress
10/09/2024HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
10/03/2024HVAC-R and service water piping design and insulationCALVIN TRANenergy_progress
10/03/2024Fenestration and door U-factor and product ratingsCALVIN TRANenergy_progress
10/03/2024Fenestration areasCALVIN TRANenergy_progress
10/03/2024Interior lighting powerCALVIN TRANenergy_progress
10/03/2024Maintenance informationCALVIN TRANenergy_progress
10/03/2024MeteringCALVIN TRANenergy_progress
10/03/2024Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
10/03/2024Fire-Resistance Rated ConstructionCALVIN TRANprogress
10/03/2024Energy Code Compliance InspectionsCALVIN TRANprogress
10/03/2024HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
10/03/2024Insulation placement and R valuesCALVIN TRANenergy_progress
10/03/2024Air barrier - visual inspectionCALVIN TRANenergy_progress
10/03/2024Fenestration air leakageCALVIN TRANenergy_progress
10/03/2024HVAC-R and service water heating system controlsCALVIN TRANenergy_progress
09/30/2024HVAC-R and service water heating equipmentCALVIN TRANenergy_progress
Latest 25 of 43.
▾Documents — 32 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/24/2026B01061277-I1Request digital key ↗
08/24/2026B01061277-P1Request digital key ↗
08/24/2026B01061277-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/13/2026B01050350-I1Open ↗
08/13/2026B01050350-P1Open ↗
08/13/2026B01061277-P2Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature10
09/01/2026B01050350-P1Open ↗
09/01/2026B01050350-P1Open ↗
09/01/2026B01050350-I1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/24/2026B01061277-P2Open ↗
08/24/2026B01061277-I1Open ↗
08/24/2026B01061277-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B01050350-P1Open ↗
09/01/2026B01050350-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/24/2026B01061277-P1Open ↗
08/24/2026B01061277-I1Open ↗
08/24/2026B01061277-P2Open ↗
Showing 3 of 5 on file for this type