← Back
Miscellaneous garage
1437 BLONDELL AVENUE
BRONX · Westchester Square · BIN 2044112
💬 Discuss this project
1931Year Built
1Stories
G9Building Class
M1-1Zoning
4,500 sfGross Floor Area
1Units
0 Open Violations
Miscellaneous garage · Owner of record: ADIL TOKUZLU LLC · 9,500 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ATAC304/21/2026
OWNER OF 2630 ST RAYMOND103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/05/2017$1.2M—1437 BLONDELL AVENUE LLC → ADIL TOKUZLU LLC$267/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GINO O. LONGO, ARCHITECT304/13/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JSPECS,INC9429105/09/2025
Building Lifecycle
All (30)Filed (3)Violation (1)Objection (10)Special Inspection (16)
07/20/2026
Objection resolved — Resolved
06/05/2026
Special inspection requirement — Maintenance information
04/27/2026
Objection raised — Energy
04/14/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jeffrey Stones
04/14/2026
Special inspection requirement — Fire-Resistance Rated Construction
Jeffrey Stones
04/14/2026
Special inspection requirement — Energy Code Compliance Inspections
Jeffrey Stones
04/14/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Jeffrey Stones
04/14/2026
Special inspection requirement — Fenestration areas
Jeffrey Stones
04/14/2026
Special inspection requirement — Air barrier - visual inspection
Jeffrey Stones
04/14/2026
Special inspection requirement — Fenestration air leakage
Jeffrey Stones
04/13/2026
Filed — Alteration CO
APPLICATION HEREWITH FILED FOR NEW CERTIFICATE OF OCCUPANCY, GENERAL CONSTRUCTION FOR PROPOSED AUTO MECHANIC SHOP.
X01197553-S1
04/08/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/01/2026
Filed — Alteration CO
APPLICATION HEREWITH FILED FOR NEW CERTIFICATE OF OCCUPANCY, GENERAL CONSTRUCTION FOR PROPOSED AUTO MECHANIC SHOP.
X01197553-P1
03/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/11/2026
Special inspection requirement — Energy Code Compliance Inspections
03/11/2026
Special inspection requirement — Fire-Resistance Rated Construction
03/11/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
03/11/2026
Special inspection requirement — Fenestration areas
03/11/2026
Special inspection requirement — Air barrier - visual inspection
03/11/2026
Special inspection requirement — Fenestration air leakage
10/17/2025
Objection resolved — Addressed
09/12/2025
Objection raised — Energy
09/05/2025
Objection resolved — Addressed
07/02/2025
Objection resolved — Addressed
06/18/2025
Objection resolved — Addressed
05/14/2025
Objection raised — Admin
05/14/2025
Objection raised — Cost
05/14/2025
Objection raised — Admin
05/09/2025
Filed — Alteration CO
APPLICATION HEREWITH FILED FOR NEW CERTIFICATE OF OCCUPANCY, GENERAL CONSTRUCTION FOR PROPOSED AUTO MECHANIC SHOP.
X01197553-I1
10/22/1999
Violation issued (ECB, closed)
Construction
Nothing on file for this building.
1 project · most recent 04/13/2026
Water/Sanitary
FiledStatusContractorScope
04/13/2026——Water/Sanitary
1 project · most recent 10/02/2018
FiledStatusContractorScope
10/02/2018Permit IssuedGEMINI ELECTRIC CO., INC.1 meters, 1 new_meters
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
06/05/2026Maintenance information—energy_progress
04/14/2026Fire-Resistant Penetrations and JointsJeffrey Stonesspecial
04/14/2026Fire-Resistance Rated ConstructionJeffrey Stonesprogress
04/14/2026Energy Code Compliance InspectionsJeffrey Stonesprogress
04/14/2026Fenestration and door U-factor and product ratingsJeffrey Stonesenergy_progress
04/14/2026Fenestration areasJeffrey Stonesenergy_progress
04/14/2026Air barrier - visual inspectionJeffrey Stonesenergy_progress
04/14/2026Fenestration air leakageJeffrey Stonesenergy_progress
04/08/2026Fire-Resistant Penetrations and Joints—special
03/11/2026Fire-Resistant Penetrations and Joints—special
03/11/2026Energy Code Compliance Inspections—progress
03/11/2026Fire-Resistance Rated Construction—progress
03/11/2026Fenestration and door U-factor and product ratings—energy_progress
03/11/2026Fenestration areas—energy_progress
03/11/2026Air barrier - visual inspection—energy_progress
03/11/2026Fenestration air leakage—energy_progress
▾Documents — 22 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/17/2026X01197553-I1Request digital key ↗
08/17/2026X01197553-P1Request digital key ↗
08/17/2026X01197553-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp2
08/17/2026X01197553-P1Open ↗
08/17/2026X01197553-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026X01197553-I1Open ↗
08/24/2026X01197553-I1Open ↗
08/24/2026X01197553-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/17/2026X01197553-I1Open ↗
08/17/2026X01197553-S1Open ↗
08/17/2026X01197553-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026X01197553-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/17/2026X01197553-P1Open ↗
08/17/2026X01197553-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026X01197553-I1Open ↗
08/17/2026X01197553-S1Open ↗
08/17/2026X01197553-P1Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification2
08/17/2026X01197553-P1Open ↗
08/17/2026X01197553-I1Open ↗