| Owner | Filings | Most Recent |
|---|---|---|
| METRO CONTRACTING NY | 7 | 03/22/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/03/2022 | $880K | — | — → — | $386/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| STUDIO GALLOS | 3 | 02/12/2026 |
| GENARO URUETA | 4 | 05/12/2025 |
| LEVIN ENGINEERING PLLC | 5 | 04/18/2024 |
| VIJAY KUMAR | 1 | 04/12/2024 |
| MSM ENGINEERING SERVICES, PLLC | 2 | 04/04/2024 |
| KEMBA WALCOTT | 3 | 05/18/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| RICHARD WAINER ARCHITECT, PLLC | 20 | 03/21/2026 |
| LEVIN ENGINEERING PLLC | 10 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| BAYPORT CONSTRUCTION CORP. | General Contractor | 14 | 07/08/2026 |
| METRO CONTRACTING NY, INC. | General Contractor | 2 | 03/21/2026 |
| DYNAMIC PLBNG & SPRKR COR | Fire Protection | 1 | 07/08/2026 |
| INFINITI ESC PLUMBING COR | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| TRIANGLE INSPECTION & TES | 7495 | 12 | 02/12/2026 |
| AZ PROFESSIONAL ENGINEERI | 766 | 1 | 04/12/2024 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Permit Issued | BAYPORT CONSTRUCTION CORP | 12/27/2024 |
| DOB NOW | General Construction | Permit Issued | BAYPORT CONSTRUCTION CORP | 10/11/2024 |
| DOB NOW | Construction Fence | Signed-off | BAYPORT CONSTRUCTION CORP | 10/07/2024 |
| DOB NOW | General Construction | Permit Issued | BAYPORT CONSTRUCTION CORP | 08/26/2024 |
| DOB NOW | Sprinklers | Signed-off | CITYWIDE PLBG, HTG &SPRKL | 06/24/2024 |
| DOB NOW | Plumbing | Signed-off | INFINITI ESC PLUMBING COR | 05/22/2024 |
| DOB NOW | Mechanical Systems | Signed-off | BAYPORT CONSTRUCTION CORP | 05/17/2024 |
| DOB NOW | Supported Scaffold | Signed-off | BAYPORT CONSTRUCTION CORP | 05/10/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | METRO CONTRACTING NY, INC. | 03/26/2024 |
| DOB NOW | Support of Excavation | Signed-off | BAYPORT CONSTRUCTION CORP | 11/13/2023 |
| DOB NOW | Foundation | Signed-off | BAYPORT CONSTRUCTION CORP | 10/30/2023 |
| DOB NOW | Structural | Signed-off | BAYPORT CONSTRUCTION CORP | 10/30/2023 |
| DOB NOW | Construction Fence | Signed-off | BAYPORT CONSTRUCTION CORP | 09/22/2023 |
| DOB NOW | General Construction | Permit Issued | BAYPORT CONSTRUCTION CORP | 08/23/2023 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 02/12/2026 | Permit Issued | BAYPORT CONSTRUCTION CORP | Air Conditioning Systems | Cooling Mitsubishi Electric MXZ-3C24NAHZ4-U1 2 tons · Heat Pump Outdoor ×4 MXZ-SM36NAMHZ2 3 tons · Heat Pump Outdoor ×2 MXZ24NAHZ4-U1 2 tons · Heat Pump Outdoor ×1 Daikin MXZ-SM36NAMHZ2 3 tons · Vrf Outdoor ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/12/2026 | Signed-off | DYNAMIC PLBNG & SPRKR COR | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 02/12/2026 | Signed-off | INFINITI ESC PLUMBING COR | Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/30/2025 | Complete | S&R ELECTRICAL & MECHANIC | General Wiring |
| 03/26/2024 | Complete | RICHARD NEU | — |
| 11/30/2023 | Complete | S&R ELECTRICAL & MECHANIC | — |
| Date | Type | Result | Report |
|---|---|---|---|
| 08/06/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/16/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 05/08/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 04/11/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 04/09/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 02/28/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 07/02/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 02/17/2026 | Construction Operations Influencing Adjacent Structures | Rajasekhar Sakhamuri | special |
| 02/17/2026 | Structural Stability – Alterations of existing buildings | Rajasekhar Sakhamuri | special |
| 02/17/2026 | Maintenance information | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Fenestration and door U-factor and product ratings | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Lighting in dwelling units | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Metering | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Interior lighting power | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Air barrier - visual inspection | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Insulation placement and R values | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Fenestration air leakage | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Air barrier — testing | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Lighting controls | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Fenestration areas | Rajasekhar Sakhamuri | energy_progress |
| 02/17/2026 | Exterior lighting power | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Air barrier — testing | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Insulation placement and R values | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Interior lighting power | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Fenestration air leakage | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Exterior lighting power | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Fenestration and door U-factor and product ratings | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Lighting controls | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Fenestration areas | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Lighting in dwelling units | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Maintenance information | Rajasekhar Sakhamuri | energy_progress |
| 02/12/2026 | Air barrier - visual inspection | Rajasekhar Sakhamuri | energy_progress |