← Back
Factory, industrial, semi-fireproof
144-08 91 AVENUE
QUEENS · Jamaica · BIN 4213882
💬 Discuss this project
1940Year Built
1Stories
F4Building Class
C6-4Zoning
10,900 sfGross Floor Area
1Units
8 Open Violations ▸FDNY Report ↗
Factory, industrial, semi-fireproof · Owner of record: 104-20 DUNKIRK REALTY CORP. · 11,950 sf lot · 0.91 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 11p · 1 filing · 11 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
10420 DUNKIRK REALTY907/08/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
M. HAMDI GUNAL, PE, P. C.211/05/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CSR EXPEDITERS203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
VIKRAM CONSTRUCTION, INCGeneral Contractor107/08/2026
J-J PLUMBING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. HAMDI GUNAL, PE, P.C.3000211/05/2019
Building Lifecycle
All (25)Filed (2)Permit Issued (2)Signed Off (1)Violation (13)Special Inspection (7)
04/09/2026
Violation issued (FDNY_NOV, closed)
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/30/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
06/20/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/25/2023
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/13/2020
Signed off — Alteration
Removal and decommission of existing gas-fired boiler in cellar, New gas riser and overhead gas piping for new gas-fired warm air furnaces at first floor. No change in use, egress or occupancy.
Q00244422-I1
12/03/2019
Permit issued — Mechanical Systems
Q00245880-I1-MS
11/25/2019
Permit issued — Plumbing
Q00244422-I1-PL
11/08/2019
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
11/05/2019
Filed — Alteration
Removal and decommission of existing gas-fired boiler in cellar, New gas riser and overhead gas piping for new gas-fired warm air furnaces at first floor. No change in use, egress or occupancy.
Q00244422-I1
11/05/2019
Filed — Alteration
INSTALLATION OF FOUR (4) NEW GAS-FIRED WARM-AIR FURNACES AT FIRST FLOOR. NO CHNAGE IN USE, EGRESS OR OCCUPANCY.
Q00245880-I1
10/15/2019
Special inspection requirement — Mechanical Systems
Mehmet Gunal
10/15/2019
Special inspection requirement — Heating Systems
Mehmet Gunal
10/15/2019
Special inspection requirement — Final
Mehmet Gunal
10/15/2019
Special inspection requirement — Energy Code Compliance Inspections
Mehmet Gunal
10/15/2019
Special inspection requirement — HVAC and service water heating equipment
Mehmet Gunal
10/15/2019
Special inspection requirement — HVAC and service water heating system controls
Mehmet Gunal
10/15/2019
Special inspection requirement — Maintenance information
Mehmet Gunal
04/06/2018
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/16/2018
Violation issued (ECB, closed)
Boilers
02/24/2017
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
10/01/2015
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
03/03/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/31/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offVIKRAM CONSTRUCTION, INC12/03/2019
DOB NOWPlumbingSigned-offJ-J PLUMBING CORP11/25/2019
BISBLISSUEDM. WOLF PLUMBING & HEATING CORP.12/09/1998
BISPLISSUEDM. WOLF PLUMBING & HEATING CORP.12/09/1998
1 project · most recent 11/05/2019
Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/05/2019Signed-offVIKRAM CONSTRUCTION, INCHeating Systems
Heating
Modine PDP-400 400,000 BTU · Furnace ×4
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/15/2019Mechanical SystemsMehmet Gunalspecial
10/15/2019Heating SystemsMehmet Gunalspecial
10/15/2019FinalMehmet Gunalprogress
10/15/2019Energy Code Compliance InspectionsMehmet Gunalprogress
10/15/2019HVAC and service water heating equipment Mehmet Gunalenergy_progress
10/15/2019HVAC and service water heating system controls Mehmet Gunalenergy_progress
10/15/2019Maintenance informationMehmet Gunalenergy_progress
▾Documents — 16 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing1
08/28/2026Q00244422-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/28/2026Q00245880-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature5
08/23/2026Q00245880-I1Open ↗
08/23/2026Q00245880-I1Open ↗
08/23/2026Q00245880-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q00245880-I1Open ↗
08/23/2026Q00245880-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026Q00244422-I1Open ↗
08/13/2026Q00245880-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/28/2026Q00244422-I1Open ↗
08/13/2026Q00245880-I1Open ↗
▸DOB NOWOER: Notice of Satisfaction1
08/28/2026Q00244422-I1Open ↗
▸DOB NOWOER: Notice to Proceed1
08/28/2026Q00244422-I1Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00245880-I1Open ↗