← Back
Two family converted from one family
144-28 JEWEL AVENUE
QUEENS · Kew Gardens Hills · BIN 4143789
💬 Discuss this project
1935Year Built
2Stories
B3Building Class
R4BZoning
1,580 sfGross Floor Area
2Units
Two family converted from one family · 2,300 sf lot · 0.69 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingGeneral
Floor 26p · 1 filing · 20 docs
Floor 16p · 1 filing · 20 docs
Cellar6p · 1 filing · 20 docs
Site & exterior5p · 1 filing · 20 docs
Filed — no permit issued7p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/14/2022$880K—Private party → Private party$557/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
HIRISE CONTRACTING GROUP, INC506/17/2024
AMERILAND BROOK LLC103/22/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AMERILAND BROOK LLC1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
XINLI.CONSTRUCTION LLCGeneral Contractor603/21/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HIRISE CONTRACTING GROUP,8228506/17/2024
Building Lifecycle
All (53)Filed (6)Permit Issued (3)Signed Off (1)Inspection (6)Objection (7)Special Inspection (30)
07/09/2024
Special inspection requirement — HVAC-R and service water heating system controls
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — HVAC-R and service water heating equipment
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Heating Systems
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Energy Code Compliance Inspections
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Fire-Resistance Rated Construction
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Final
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Insulation placement and R values
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Mechanical Systems
ROBERT ERVOLINA
07/09/2024
Special inspection requirement — Interior lighting power
ROBERT ERVOLINA
06/17/2024
Filed — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-P3
06/17/2024
Special inspection requirement — HVAC-R and service water heating equipment
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Heating Systems
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Mechanical Systems
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Energy Code Compliance Inspections
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Final
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Fire-Resistance Rated Construction
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Interior lighting power
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — Insulation placement and R values
ROBERT ERVOLINA
06/17/2024
Special inspection requirement — HVAC-R and service water heating system controls
ROBERT ERVOLINA
06/10/2024
Signed off — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-S1
03/08/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/01/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
02/01/2024
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
01/06/2024
Filed — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-P2
01/06/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Heating Systems
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Mechanical Systems
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Energy Code Compliance Inspections
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Final
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — Fire-Resistance Rated Construction
ROBERT ERVOLINA
01/06/2024
Special inspection requirement — HVAC-R and service water heating system controls
ROBERT ERVOLINA
09/28/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/25/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/19/2023
Filed — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-P1
07/11/2023
Permit issued — Plumbing
Q00886286-S1-PL
06/30/2023
Permit issued — Mechanical Systems
Q00886286-I1-MS
06/30/2023
Permit issued — General Construction
Q00886286-I1-GC
06/18/2023
Objection resolved — Addressed
06/17/2023
Filed — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-S1
06/15/2023
Objection raised — Other
06/06/2023
Filed — Alteration CO
FILE PL WORKTYPE IN CONJUNCTION WITH JOB#Q00886286
Q00886286-I1
03/29/2023
Objection raised — Zoning
03/29/2023
Objection raised — Fire_Protection
03/29/2023
Objection raised — Inspections
03/29/2023
Objection resolved — Addressed
03/29/2023
Objection raised — Admin
03/22/2023
Filed — Alteration CO
INTERIOR RENOVATION OF EXISTING 2 STORY WITH CELLAR BUILDING. CONVERT EXISTING ONE FAMILY TO TWO FAMILY. PROPOSE PLUMBING AND GENERAL CONSTRUCTION WORK AS PERM PLAN FILED HEREWITH. OBTAIN NEW C OF O.
Q00846086-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offWATSON'S PLBG, HTG, & BDG07/11/2023
DOB NOWMechanical SystemsSigned-offXINLI.CONSTRUCTION LLC06/30/2023
DOB NOWGeneral ConstructionPermit IssuedXINLI.CONSTRUCTION LLC06/30/2023
BISPLISSUEDFOUR POINTS P & H CORP11/08/1993
BIS—ISSUEDEUROPEAN BUILDERS08/24/1993
2 projects · most recent 06/17/2024
Associated Ducts and Piping Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
06/17/2024Signed-offXINLI.CONSTRUCTION LLCAssociated Ducts and Piping, Heating Systems
Heating
Weil-Mclain CGA-5 113,000 BTU · Boiler ×6
Ducts & Piping
Delta Breeze SLIM50 50 CFM · Exhaust Fan ×12
Air King EB30BL 130 CFM · Kitchen Exhaust ×6
03/22/2023——Associated Ducts and Piping, Heating Systems
Heating
Weil-Mclain CGA-5 113,000 BTU · Boiler ×2
Ducts & Piping
Delta Breeze SLIM50 50 CFM · Exhaust Fan ×4
Air King EB30BL 130 CFM · Kitchen Exhaust ×2
1 project · most recent 06/17/2024
Gas Water/Sanitary
FiledStatusContractorScope
06/17/2024Signed-offWATSON'S PLBG, HTG, & BDGGas, Water/Sanitary
1 project · most recent 07/18/2023
General Wiring
FiledStatusContractorScope
07/18/2023CompleteKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/08/2024Pass-Final CND-Occupancy InspectionPassView ↗
03/01/2024Fail-Final CND-Occupancy InspectionFailView ↗
02/01/2024Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/28/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/25/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 41
DateRequirementInspectorRole
07/09/2024HVAC-R and service water heating system controlsROBERT ERVOLINAenergy_progress
07/09/2024HVAC-R and service water heating equipmentROBERT ERVOLINAenergy_progress
07/09/2024Heating SystemsROBERT ERVOLINAspecial
07/09/2024Fire-Resistant Penetrations and JointsROBERT ERVOLINAspecial
07/09/2024Energy Code Compliance InspectionsROBERT ERVOLINAprogress
07/09/2024Fire-Resistance Rated ConstructionROBERT ERVOLINAprogress
07/09/2024FinalROBERT ERVOLINAprogress
07/09/2024Insulation placement and R valuesROBERT ERVOLINAenergy_progress
07/09/2024HVAC-R and service water piping design and insulationROBERT ERVOLINAenergy_progress
07/09/2024Mechanical SystemsROBERT ERVOLINAspecial
07/09/2024Interior lighting powerROBERT ERVOLINAenergy_progress
06/17/2024HVAC-R and service water heating equipmentROBERT ERVOLINAenergy_progress
06/17/2024HVAC-R and service water piping design and insulationROBERT ERVOLINAenergy_progress
06/17/2024Fire-Resistant Penetrations and JointsROBERT ERVOLINAspecial
06/17/2024Heating SystemsROBERT ERVOLINAspecial
06/17/2024Mechanical SystemsROBERT ERVOLINAspecial
06/17/2024Energy Code Compliance InspectionsROBERT ERVOLINAprogress
06/17/2024FinalROBERT ERVOLINAprogress
06/17/2024Fire-Resistance Rated ConstructionROBERT ERVOLINAprogress
06/17/2024Interior lighting powerROBERT ERVOLINAenergy_progress
06/17/2024Insulation placement and R valuesROBERT ERVOLINAenergy_progress
06/17/2024HVAC-R and service water heating system controlsROBERT ERVOLINAenergy_progress
01/06/2024HVAC-R and service water piping design and insulationROBERT ERVOLINAenergy_progress
01/06/2024Fire-Resistant Penetrations and JointsROBERT ERVOLINAspecial
01/06/2024Heating SystemsROBERT ERVOLINAspecial
Latest 25 of 41.
▾Documents — 34 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
08/23/2026Q00886286-P3Request digital key ↗
08/23/2026Q00886286-I1Request digital key ↗
08/23/2026Q00886286-P1Request digital key ↗
Showing 3 of 6 on file for this type
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00886286-I1Open ↗
▸Seals & Professional Certifications23
▸DOB NOWProgress Inspector Seal & Signature12
10/01/2026Q00886286-S1Open ↗
08/31/2026Q00886286-I1Open ↗
08/31/2026Q00886286-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/25/2026Q00846086-I1Open ↗
08/23/2026Q00886286-P3Open ↗
08/23/2026Q00886286-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
10/01/2026Q00886286-S1Open ↗
08/31/2026Q00886286-I1Open ↗
08/26/2026Q00886286-P2Open ↗
Showing 3 of 5 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification3
08/23/2026Q00886286-I1Open ↗
08/23/2026Q00886286-P3Open ↗
08/23/2026Q00886286-P2Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00886286-I1Open ↗