← Back
One family attached or semi-detached
144-44 69 AVENUE
QUEENS · BIN 4143693
💬 Discuss this project
1940Year Built
2Stories
A5Building Class
R4BZoning
1,224 sfGross Floor Area
1Units
0 Open Violations
One family attached or semi-detached · 1,710 sf lot · 0.72 FAR built · Flood zone X
Locations of Work
Electrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/29/2021$710K—Private party → Private party$580/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SQUARE ARCH, LLC108/24/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor109/12/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SQ. ARCH, LLC4802108/24/2026
Building Lifecycle
All (8)Filed (1)Permit Issued (1)Violation (1)Special Inspection (5)
09/10/2026
Permit issued — Solar
Q01448947-I1-SL
08/24/2026
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01448947-I1
08/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Kaijin Liang
08/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Kaijin Liang
08/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Kaijin Liang
08/20/2026
Special inspection requirement — Final
Kaijin Liang
08/20/2026
Special inspection requirement — Air barrier - visual inspection
Kaijin Liang
04/20/2005
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedKAMTECH RESTORATION CORP09/10/2026
1 project · most recent 08/19/2026
FiledStatusContractorScope
08/19/2026Permit IssuedBERGER QUALITY ELEC'L CON—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/20/2026Structural Stability – Alterations of existing buildingsKaijin Liangspecial
08/20/2026Fire-Resistant Penetrations and JointsKaijin Liangspecial
08/20/2026Energy Code Compliance InspectionsKaijin Liangprogress
08/20/2026FinalKaijin Liangprogress
08/20/2026Air barrier - visual inspectionKaijin Liangenergy_progress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/25/2026Q01448947-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
09/11/2026Q01448947-I1Open ↗
09/11/2026Q01448947-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/25/2026Q01448947-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/11/2026Q01448947-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/25/2026Q01448947-I1Open ↗