← Back
BuildNYC
One story - permanent living quarter
144-46 223 STREET
💬 Discuss this project
1935Year Built
1Stories
A2Building Class
R3-1Zoning
797 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One story - permanent living quarter · 2,850 sf lot · 0.28 FAR built · Flood zone X
Locations of Work
Electrical
Roof2p · 1 filing · 15 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/11/2019$500K—DRN HOLDINGS CORP → Private party$627/sf building
12/04/2018$205K—Private party → DRN HOLDINGS CORP$257/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC201/15/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036201/15/2026
Building Lifecycle
All (15)Filed (2)Permit Issued (1)Signed Off (1)Violation (3)Special Inspection (8)
03/09/2026
Signed off — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01181646-I1
01/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
01/21/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
01/21/2026
Special inspection requirement — Final
Ayracon Almaraz
01/21/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
01/15/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01181646-P1
01/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
KAMRUL AHSAN
01/15/2026
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
01/15/2026
Special inspection requirement — Final
Ayracon Almaraz
01/15/2026
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
11/17/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/24/2025
Permit issued — Solar
Q01181646-I1-SL
02/17/2025
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01181646-I1
03/05/2009
Violation issued (ECB, closed)
Construction
03/05/2009
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTRINITY SOLAR LLC02/24/2025
2 projects · most recent 02/12/2025
FiledStatusContractorScope
02/12/2025CompleteREDLINE ELECTRIC INC—
05/12/2021CompleteSTRONG ISLAND ELECTRIC LL—
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
01/21/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
01/21/2026Energy Code Compliance InspectionsAyracon Almarazprogress
01/21/2026FinalAyracon Almarazprogress
01/21/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
01/15/2026Fire-Resistant Penetrations and JointsKAMRUL AHSANspecial
01/15/2026Energy Code Compliance InspectionsAyracon Almarazprogress
01/15/2026FinalAyracon Almarazprogress
01/15/2026Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 15 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/17/2026Q01181646-I1Request digital key ↗
08/17/2026Q01181646-P1Request digital key ↗
▸Seals & Professional Certifications10
▸DOB NOWProgress Inspector Seal & Signature6
08/24/2026Q01181646-I1Open ↗
08/24/2026Q01181646-I1Open ↗
08/24/2026Q01181646-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/17/2026Q01181646-I1Open ↗
08/13/2026Q01181646-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026Q01181646-I1Open ↗
08/24/2026Q01181646-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/17/2026Q01181646-I1Open ↗
08/13/2026Q01181646-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01181646-I1Open ↗