← Back
Two family converted from one family
144-55 76 ROAD
QUEENS · BIN 4144257
💬 Discuss this project
1940Year Built
2Stories
B3Building Class
R4Zoning
2,370 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 2,000 sf lot · 1.19 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbing
Floor 23p · 2 filings · 16 docs
Floor 13p · 2 filings · 20 docs
Basement5p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SPLEN CONSTRUCTION203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/24/2019$805K—Private party → Private party$340/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALBERT ARONOV ARCHITECT512/28/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SPLEN CONSTRUCTION INCGeneral Contractor407/08/2026
KJK ELECTRIC INCElectrical103/22/2026
QMB PLUMBING & HEATING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALBERT ARONOV772412/28/2023
Building Lifecycle
All (50)Filed (4)Permit Issued (3)Signed Off (2)Violation (6)Inspection (8)Objection (8)Special Inspection (19)
01/22/2024
Signed off — Alteration
REFILING JOB TO AMEND DRAWINGS FILED ON JOB Q00716868-I1 TO COMPLY WITH INSPECTOR'S COMMENTS. JOB Q00716868-I1 DOES NOT ALLOW AMENDMENTS THEREFORE THIS SUBSEQUENT JOB FILED.
Q00716868-I1
12/28/2023
Filed — Alteration
REFILING JOB TO AMEND DRAWINGS FILED ON JOB Q00716868-I1 TO COMPLY WITH INSPECTOR'S COMMENTS. JOB Q00716868-I1 DOES NOT ALLOW AMENDMENTS THEREFORE THIS SUBSEQUENT JOB FILED.
Q00716868-S1
12/28/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Albert Aronov
08/03/2023
Violation issued (ECB, closed)
Construction
07/05/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/08/2023
Signed off — Alteration
Q00747429-I1
02/07/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/22/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
11/18/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/05/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/05/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/03/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/02/2022
Violation issued (ECB, closed)
Unknown
08/02/2022
Violation issued (ECB, closed)
Construction
08/02/2022
Violation issued (ECB, closed)
Site Safety
06/27/2022
Permit issued — Plumbing
Q00716868-I1-PL
06/15/2022
Permit issued — Construction Fence
Q00747429-I1-FN
06/04/2022
Permit issued — General Construction
Q00715702-I1-GC-CX
05/27/2022
Filed — Alteration
Q00747429-I1
04/13/2022
Objection raised — Other
04/13/2022
Objection resolved — Addressed
04/13/2022
Objection raised — Scope
04/13/2022
Objection resolved — Addressed
04/13/2022
Objection raised — Structural
04/13/2022
Objection resolved — Addressed
04/13/2022
Objection raised — Scope
04/13/2022
Objection resolved — Addressed
04/11/2022
Filed — Alteration
REFILING JOB TO AMEND DRAWINGS FILED ON JOB Q00716868-I1 TO COMPLY WITH INSPECTOR'S COMMENTS. JOB Q00716868-I1 DOES NOT ALLOW AMENDMENTS THEREFORE THIS SUBSEQUENT JOB FILED.
Q00716868-I1
04/11/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Albert Aronov
04/10/2022
Filed — Alteration CO
Q00715702-I1
04/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Albert Aronov
04/08/2022
Special inspection requirement — Heating Systems
Albert Aronov
04/08/2022
Special inspection requirement — Mechanical Systems
Albert Aronov
04/08/2022
Special inspection requirement — Structural Cold-Formed Steel
Albert Aronov
04/08/2022
Special inspection requirement — Final
Albert Aronov
04/08/2022
Special inspection requirement — Air barrier - visual inspection
Albert Aronov
04/08/2022
Special inspection requirement — Fenestration areas
Albert Aronov
04/08/2022
Special inspection requirement — Fenestration air leakage
Albert Aronov
04/08/2022
Special inspection requirement — Lighting controls
Albert Aronov
04/08/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Albert Aronov
04/08/2022
Special inspection requirement — HVAC-R and service water heating equipment
Albert Aronov
04/08/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Albert Aronov
04/08/2022
Special inspection requirement — HVAC-R and service water heating system controls
Albert Aronov
04/08/2022
Special inspection requirement — Insulation placement and R values
Albert Aronov
04/08/2022
Special inspection requirement — Permanent certificate
Albert Aronov
04/08/2022
Special inspection requirement — Interior lighting power
Albert Aronov
04/08/2022
Special inspection requirement — Shutoff dampers
Albert Aronov
03/17/2022
Violation issued (ECB, closed)
Construction
03/17/2022
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC06/27/2022
DOB NOWConstruction FenceSigned-offSPLEN CONSTRUCTION INC06/15/2022
DOB NOWGeneral ConstructionPermit IssuedSPLEN CONSTRUCTION INC06/04/2022
1 project · most recent 04/10/2022
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
04/10/2022Permit IssuedSPLEN CONSTRUCTION INCAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MSZ-GL12NA 12,000 BTU · Heat Pump Outdoor ×2
MSZ-GL18NA 18,000 BTU · Heat Pump Outdoor ×1
MXZ-3C30NA2 30,000 BTU · Heat Pump Outdoor ×1
MXZ-4C36NA2 36,000 BTU · Heat Pump Outdoor ×1
Heating
Triangle Tube INSTINCT COMBI 199 199,000 BTU · Boiler ×1
1 project · most recent 12/28/2023
Gas Water/Sanitary
FiledStatusContractorScope
12/28/2023Signed-offQMB PLUMBING & HEATING INGas, Water/Sanitary
1 project · most recent 11/02/2022
General Wiring
FiledStatusContractorScope
11/02/2022CompleteKJK ELECTRIC INCGeneral Wiring
1 project · most recent 04/10/2022
FiledStatusContractorScope
04/10/2022Permit IssuedSPLEN CONSTRUCTION INC1 scope_items
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
07/05/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/07/2023Pass-Final CND-Occupancy InspectionPassView ↗
12/22/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
11/18/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/05/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/05/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/05/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/03/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 19
DateRequirementInspectorRole
12/28/2023Fire-Resistant Penetrations and JointsAlbert Aronovspecial
04/11/2022Fire-Resistant Penetrations and JointsAlbert Aronovspecial
04/08/2022Fire-Resistant Penetrations and JointsAlbert Aronovspecial
04/08/2022Heating SystemsAlbert Aronovspecial
04/08/2022Mechanical SystemsAlbert Aronovspecial
04/08/2022Structural Cold-Formed SteelAlbert Aronovspecial
04/08/2022FinalAlbert Aronovprogress
04/08/2022Air barrier - visual inspectionAlbert Aronovenergy_progress
04/08/2022Fenestration areasAlbert Aronovenergy_progress
04/08/2022Fenestration air leakageAlbert Aronovenergy_progress
04/08/2022Lighting controlsAlbert Aronovenergy_progress
04/08/2022HVAC-R and service water piping design and insulationAlbert Aronovenergy_progress
04/08/2022HVAC-R and service water heating equipmentAlbert Aronovenergy_progress
04/08/2022Fenestration and door U-factor and product ratingsAlbert Aronovenergy_progress
04/08/2022HVAC-R and service water heating system controlsAlbert Aronovenergy_progress
04/08/2022Insulation placement and R valuesAlbert Aronovenergy_progress
04/08/2022Permanent certificateAlbert Aronovenergy_progress
04/08/2022Interior lighting powerAlbert Aronovenergy_progress
04/08/2022Shutoff dampersAlbert Aronovenergy_progress
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/26/2026Q00747429-I1Request digital key ↗
08/23/2026Q00716868-S1Request digital key ↗
08/23/2026Q00716868-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00715702-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00715702-I1Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/23/2026Q00716868-S1Open ↗
08/23/2026Q00716868-I1Open ↗
08/13/2026Q00715702-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/17/2026Q00716868-S1Open ↗
09/02/2026Q00716868-I1Open ↗
09/01/2026Q00715702-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q00715702-I1Open ↗
09/01/2026Q00715702-I1Open ↗
09/01/2026Q00715702-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00715702-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00715702-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/23/2026Q00716868-I1Open ↗
08/23/2026Q00716868-S1Open ↗
08/13/2026Q00715702-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00715702-I1Open ↗
▸Other Documents4
▸DOB NOWFinal Survey1
08/13/2026Q00715702-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/15/2026Q00715702-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00715702-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q00715702-I1Open ↗