DOB08/26/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT THE TIME OF INSPECTION, OBSERVED LONG VERTICAL CRACK/DISPLACED/BULGING BRICKS MASONRY WALL AT ALL EXPOSURES. SPALLING BRICK MASONRY OBSERVED AT EXPOSURE 4. REMEDY: REPAIR AND/OR REPLACE
DOB11/14/2025VIOLATION ISSUED-FAILURE TO FILE 2024 EXTERNAL LOW PRESSURE INSPECTION
ECB10/30/2024FAILURE TO FILE REQUIRED ANNUAL BOILER INSPECTION REPORTS FOR LOW-PRESSURE BOILER 30000114811N0001 IN ACCORDANCE WITH THE RULES OF THE DEPARTMENT.1RCNY 103-01(D)(1)REQUIRES THAT AN ANNUAL INSPECTION REPORT FOR$3K due
DOB09/23/2024VIOLATION ISSUED-FAILURE TO FILE 2023 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2021 EXTERNAL LOW PRESSURE INSPECTION
DOB06/30/2023VIOLATION ISSUED-FAILURE TO FILE 2020 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2019 EXTERNAL LOW PRESSURE INSPECTION
DOB06/20/2023VIOLATION ISSUED-FAILURE TO FILE 2018 EXTERNAL LOW PRESSURE INSPECTION
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB05/18/2022UNLAWFUL ACTS-FAIL TO COMPLY W/COMMISSIONER'S ORDER#051822FEU30201IK WHICH RQUIRED,IN PART,THAT THE OWNER FILE AN APPLICATION TO PERFORM NECESSARY FACADE REPAIRS.AS OF 8/5/22,DOB RECORDS DO NOT REFLECT THE FILING OF ANY SUCH APPLICATION. COMPLY W/COMMISSIONER'S ORDER# 051822FEU30201IK
DOB05/18/2022FTM BLDG IN SAFE CONDITION. AT ALL EXTERIOR WALLS: MULTIPLEVERTICAL CRACKS FROM GROUND TO TOP OF STRUCTURE: BROKEN ANDDETERIORATED WINDOWS .PONDING WATER ON ROOFS @ EXTERIOR OWNER TO RETAIN NYS LIC PROF AND DOB REG'D CONSTRACTOR TO EVAL BLDG & REPAIR UNDER PERMIT. BEGIN WORK BY 8/15/2022
DOB05/10/2022INSTALL APPROXIMATELY 165 LINEAR FEET OF SIDEWALK SHED TO COVER THE ENTIRE LENGTH OF THE BUILDING ON THE SIDE OF SAINT FELIX STREET AS PEDESTRIAN PROTECTION
DOB09/10/2015FM VARIOUS CRACKS THROUGH EXTERIOR MASONRY WALLS & DECORATIVE STONE ELEMENTS AT ALL EXPOSURES OF BLDG. OTHER SIGNS OF WATER DAMAGE THROUGH OUT INTERIOR AND EXTERIOR OF BLDG SUCH AS EFFLORESENCE.REMEDY: OWNER TO ENGAGE LIC PE TO EVALUATE THE DEFECTS IN THE BLDG. DRWGS TO BE FILED NO LTR THAN 10/30/15WRK UNDER PERMIT TO BEGIN NO LTR THAN 1/4/16
DOB03/18/2011VPW-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-ACTIVE
DOB08/14/2009V-DOB VIOLATION - ACTIVE
DOB07/21/2009V-DOB VIOLATION - ACTIVE
DOB06/30/2009WORK WITHOUT A PERMIT, REMEDY; STOP ALL WORK IMMEDIATELY, MAKE SITE SAFE OBTAIN A PERMIT IF FEASIBLE
DOB04/13/2009FAILURE TO MAINTIAN BUILDING WALLS OR APPURTENANCES OBSERVED PIECES OF MASONRY AND CAULK FALLING FROM FACADE AT 13 HANSON PLACE REMEDY: MAINTAIN EXTERIOR BUILDING WALL CALL SEP 212 442-1544
DOB01/10/2007V-DOB VIOLATION - ACTIVE
DOB08/30/2000V-DOB VIOLATION - ACTIVE
DOB08/30/2000V-DOB VIOLATION - ACTIVE
DOB08/30/2000V-DOB VIOLATION - ACTIVE
ECB07/06/2023NOTED, MULTIPLE VERTICAL CRACKS IN BRICK EXTERIOR BUILDING WALLS AT VARIOUS LOCATIONS ON 3RD AND 4TH FLOOR BEHIND EXPOSURE #1, AT EXPOSURE 4 AT AND EXPOSURE #3 ON FACADE, SUMMONS SITE #34775635Z AND 34810343H.Nothing owed — awaiting certificate of correction
ECB01/07/2010FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCESNOTE:MULTIPLE VERTI CAL CRACKS WITH OPENINGS OF APPROXIMATELY 1" WIDE OBSERVED ON THE EAST SIDE (#4)FACADE.CRACKS ALSO OBSERVED AT THE REAR FACADE.REMEDY:REPAIRNothing owed — awaiting certificate of correction
ECB07/11/2009UNLAWFULLY CONTINUED WORK WHILE ON NOTICE OF A STOP WORK ORDER. WORKING AT PARTITION FRONT PLEXIGLASS W/HAND TORCH. REMEDY: COMPLY W/SWO.Nothing owed — awaiting certificate of correction
ECB05/07/2009FAILURE TO MAINTAIN BUILDING WALLS OR APPURTENANCES. NOTE: MULTIPLE VERTICAL CRACKS 15'LONG X 1" - 1 1/2" WIDE IN BRICK EXTERIOR BUILDING WALLS AT A VARIOUS LOCATIONS AT 3RD & 4TH FLR AT REAR & SIDE EXTERIORNothing owed — awaiting certificate of correction
ECB10/08/2002FAILURE TO PROVIDE INTERIOR FIRE ALARM SYSTEM AND SIGNAL SYSTEM WHERE REQUIRED. NOTED: AT 2ND FLOOR (INTERIOR BLDG) (3) THREE CLASSROOM WITH (20) TWENTY (APPROX) EACH AND (!) ONE AUDITORIUM APPROX 75 PEOPLE NONothing owed — awaiting certificate of correction