1920Year Built
3Stories
A3Building Class
R5Zoning
3,875 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Large suburban residence · 3,013 sf lot · 1.29 FAR built · Flood zone X
Locations of Work
Plumbing
Roof1p · 1 filing · 9 docs
Cellar2p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
KHAIKA CONSTRUCTION303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/27/2019$935K—Private party → Private party$241/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
THOMAS SALAZAR, LLC307/11/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACDE GROUP103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KHAIKA CONSTRUCTION INCGeneral Contractor107/08/2026
A. M. PLUMBING COMPANYPlumbing107/08/2026
HOD PIPING & HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
M. INT'L ENGINEERING PLLC3129207/11/2024
Building Lifecycle
All (24)Filed (3)Permit Issued (3)Signed Off (2)Violation (5)Inspection (5)Objection (2)Special Inspection (4)
09/19/2024
Signed off — Alteration
FILING FOR PLUMBING WORK IN CONJUNCTION WITH APPLICATION 340769029.
B00645082-I1
07/23/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
07/23/2024
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
07/17/2024
Objection resolved — Addressed
07/15/2024
Objection raised — Inspections
07/11/2024
Filed — Alteration
FILING FOR PLUMBING WORK IN CONJUNCTION WITH APPLICATION 340769029.
B00645082-P1
06/24/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
NANIK MASSAND
06/24/2024
Special inspection requirement — Energy Code Compliance Inspections
NANIK MASSAND
06/10/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/10/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/02/2024
Permit issued — Plumbing
B00645082-I1-PL
03/28/2024
Signed off — Alteration
B00429592-I1
11/14/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/14/2022
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/14/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/10/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
09/10/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/14/2022
Permit issued — Plumbing
B00645082-I1-PL
06/10/2022
Violation issued (ECB, closed)
Construction
03/26/2022
Violation issued (ECB, closed)
Construction
03/26/2022
Violation issued (ECB, closed)
Construction
12/21/2021
Filed — Alteration
FILING FOR PLUMBING WORK IN CONJUNCTION WITH APPLICATION 340769029.
B00645082-I1
12/14/2021
Permit issued — Construction Fence
B00429592-I1-FN
11/18/2020
Filed — Alteration
B00429592-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHOD PIPING & HEATING CORP04/02/2024
DOB NOWPlumbingSigned-offA. M. PLUMBING COMPANY06/14/2022
DOB NOWConstruction FenceSigned-offKHAIKA CONSTRUCTION INC12/14/2021
BIS—ISSUEDKHAIKA CONSTRUCTION INC09/28/2023
BIS—ISSUEDKHAIKA CONSTRUCTION INC08/30/2023
BIS—ISSUEDKHAIKA CONSTRUCTION INC08/30/2023
BIS—ISSUEDKHAIKA CONSTRUCTION INC01/20/2023
BIS—ISSUEDKHAIKA CONSTRUCTION INC10/14/2022
BIS—ISSUEDKHAIKA CONSTRUCTION INC10/14/2022
BIS—ISSUEDKHAIKA CONSTRUCTION INC12/17/2021
BIS—ISSUEDKHAIKA CONSTRUCTION INC12/17/2021
1 project · most recent 08/06/2024
General Wiring
FiledStatusContractorScope
08/06/2024CompleteKINGS ELECTRIC CO., INC.General Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/10/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/10/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
11/14/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/14/2022Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/14/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
07/23/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
07/23/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
06/24/2024Fire-Resistant Penetrations and JointsNANIK MASSANDspecial
06/24/2024Energy Code Compliance InspectionsNANIK MASSANDprogress
▾Documents — 85 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch2
08/31/2026B00645082-P1Request digital key ↗
08/31/2026B00645082-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00429592-I1Request digital key ↗
▸Applications & Permits16
▸BISPLAN / WORK APPROVAL APPLICATION8
09/25/2024340769029Open ↗
11/20/2020340769029Open ↗
11/20/2020340769029Open ↗
Showing 3 of 8 on file for this type
▸BISWORK PERMIT APPLICATION4
10/03/2023340769029Open ↗
12/18/2021340769029Open ↗
12/18/2021340769029Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
04/05/2024340769029Open ↗
▸BISPARTIAL DEMO: 10-DAY NOTICE (FOR AL/EW-OT PERMITS)1
12/11/2021340769029Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
09/26/2024340769029Open ↗
▸BISPARTIAL DEMO PLAN & DS1 (FOR AL/EW-OT PERMITS)1
12/11/2021340769029Open ↗
▸Zoning, Tax Lot & Property Records5
▸BISZONING DIAGRAM2
11/16/2020340769029Open ↗
11/09/2020340769029Open ↗
▸BISVERIFY TAX LOT1
06/20/2024340769029Open ↗
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
06/20/2024340769029Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
10/15/2020340769029Open ↗
▸Seals & Professional Certifications10
▸DOB NOWDPL-1: Design Professional Seal & Signature3
09/02/2026B00429592-I1Open ↗
08/31/2026B00645082-P1Open ↗
08/31/2026B00645082-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026B00645082-I1Open ↗
08/26/2026B00645082-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026B00645082-I1Open ↗
08/26/2026B00645082-P1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
10/15/2020340769029Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/15/2020340769029Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/18/2021340769029Open ↗
▸Safety & Tenant Protection5
▸BISSTREET TREE CHECKLIST2
10/08/2024340769029Open ↗
10/15/2020340769029Open ↗
▸BISEXCAVATION - SHEETING, SHORING, AND BRACING1
04/08/2024340769029Open ↗
▸BISSTREET TREES: RECEIPT OF STREET TREES SITE PLAN1
12/11/2021340769029Open ↗
▸BISSTREET TREE SIGNOFF1
09/16/2024340769029Open ↗
▸Environmental & Asbestos2
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
11/24/2020340769029Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/31/2026B00645082-I1Open ↗
▸Energy Compliance13
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY4
04/08/2024340769029Open ↗
04/08/2024340769029Open ↗
12/11/2021340769029Open ↗
Showing 3 of 4 on file for this type
▸BISAIR SEALING AND INSULATION - VISUAL1
04/08/2024340769029Open ↗
▸BISINTERIOR LIGHTING POWER1
04/08/2024340769029Open ↗
▸BISFENESTRATION U-FACTOR & PRODUCT RATING1
04/08/2024340769029Open ↗
▸BISFENESTRATION AREAS1
04/08/2024340769029Open ↗
▸BISINSULATION PLACEMENT & R VALUES1
04/08/2024340769029Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS1
04/08/2024340769029Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
06/20/2024340769029Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/15/2020340769029Open ↗
▸BISFENESTRATION AIR LEAKAGE1
04/08/2024340769029Open ↗
▸Inspections & Test Reports16
▸BISTECHNICAL REPORT: RESPONSIBILITY7
04/08/2024340769029Open ↗
04/08/2024340769029Open ↗
01/06/2022340769029Open ↗
Showing 3 of 7 on file for this type
▸BISCONCRETE - CAST-IN-PLACE1
04/08/2024340769029Open ↗
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS1
04/08/2024340769029Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)1
04/08/2024340769029Open ↗
▸BISFIRE-RESISTIVE RATED CONSTRUCTION1
04/08/2024340769029Open ↗
▸BISFOOTING AND FOUNDATION INSPECTION1
04/08/2024340769029Open ↗
▸BISMASONRY1
04/08/2024340769029Open ↗
▸BISSOIL PERC. TEST-PVT ON-SITE STORM WATER DRAINAGE DISPOSAL SYS & DET. FACL.1
04/08/2024340769029Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
11/09/2020340769029Open ↗
▸BISFRAME (2008)/STRUCTURAL WOOD FRAME (2014) INSPECTION1
04/08/2024340769029Open ↗
▸Approvals, Objections & Sign-offs5
▸BISSCHEDULE A - OCCUPANCY / USE3
09/25/2024340769029Open ↗
10/26/2020340769029Open ↗
10/15/2020340769029Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
10/30/2020340769029Open ↗
▸BISSUPERSEDING LETTER1
10/03/2023340769029Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
10/15/2020340769029Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
06/18/2024340769029Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
11/20/2020340769029Open ↗
11/20/2020340769029Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/15/2020340769029Open ↗
▸BISADDITIONAL INFORMATION1
10/08/2024340769029Open ↗
▸Other Documents4
▸BISSUSTAINABLE ROOF ZONE FORM1
10/15/2020340769029Open ↗
▸BISMAINTENANCE INFORMATION1
04/08/2024340769029Open ↗
▸BISPERMANENT CERTIFICATE1
04/08/2024340769029Open ↗
▸BISPROTECTION OF EXPOSED FOUNDATION INSULATION1