← Back
Two family frame
1442 EAST 4 STREET
BROOKLYN · Mapleton-Midwood (West) · BIN 3172780
💬 Discuss this project
1930Year Built
2Stories
B2Building Class
R5Zoning
2,112 sfGross Floor Area
2Units
1 Open Violation ▸FDNY Report ↗
Two family frame · 2,517 sf lot · 0.84 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 22p · 2 filings · 20 docs
Floor 1
Cellar2p · 1 filing · 12 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/14/2019$999K—— → —$473/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JIS CONSULTING610/25/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SELF EMPLOYED603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FRIED ELECTRIC CO 000558General Contractor603/22/2026
DOUG'S PLBG & HTG SERV COPlumbing307/08/2026
TCS CONSTRUCTION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
JS BUILDING CONSULTING4959210/25/2021
Building Lifecycle
All (19)Filed (6)Permit Issued (3)Signed Off (2)Violation (2)Special Inspection (6)
11/22/2021
Signed off — Alteration
RENOVATION OF BUILDING; WORK TYPE MECHANICAL; THIS APPLICATION HAS BEEN FILED IN ORDER TO INSTALL THREE SPLIT SYSTEM HVAC UNITS AND DEDICATED KITCHEN AND BATHROOM EXHAUST FANS. WORK DONE IN CONJUNCTION WITH BUILDING RENOVATIONS.
B00274617-I1
10/25/2021
Filed — Alteration
RENOVATION OF BUILDING; WORK TYPE MECHANICAL; THIS APPLICATION HAS BEEN FILED IN ORDER TO INSTALL THREE SPLIT SYSTEM HVAC UNITS AND DEDICATED KITCHEN AND BATHROOM EXHAUST FANS. WORK DONE IN CONJUNCTION WITH BUILDING RENOVATIONS.
B00274617-P1
10/18/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
Julian Saavedra
10/18/2021
Special inspection requirement — Mechanical Systems
Julian Saavedra
10/18/2021
Special inspection requirement — Energy Code Compliance Inspections
Julian Saavedra
10/18/2021
Special inspection requirement — Final
Julian Saavedra
10/18/2021
Special inspection requirement — HVAC and service water heating equipment
Julian Saavedra
10/18/2021
Special inspection requirement — Maintenance information
Julian Saavedra
08/04/2021
Signed off — Alteration
Installation of plumbing fixtures associated with interior renovation of space.
B00274599-I1
06/21/2021
Permit issued — Plumbing
B00274599-I1-PL
05/07/2021
Filed — Alteration
Installation of plumbing fixtures associated with interior renovation of space.
B00274599-P3
04/08/2021
Filed — Alteration
Installation of plumbing fixtures associated with interior renovation of space.
B00274599-P2
02/23/2021
Permit issued — Mechanical Systems
B00274617-I1-MS
11/30/2020
Filed — Alteration
Installation of plumbing fixtures associated with interior renovation of space.
B00274599-P1
06/27/2020
Filed — Alteration
RENOVATION OF BUILDING; WORK TYPE MECHANICAL; THIS APPLICATION HAS BEEN FILED IN ORDER TO INSTALL THREE SPLIT SYSTEM HVAC UNITS AND DEDICATED KITCHEN AND BATHROOM EXHAUST FANS. WORK DONE IN CONJUNCTION WITH BUILDING RENOVATIONS.
B00274617-I1
06/17/2020
Permit issued — Plumbing
B00274599-I1-PL
02/14/2020
Filed — Alteration
Installation of plumbing fixtures associated with interior renovation of space.
B00274599-I1
08/20/2011
Violation issued (ECB, closed)
Construction
08/07/2011
Violation issued (HPD, open)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offDOUG'S PLBG & HTG SERV CO06/21/2021
DOB NOWMechanical SystemsSigned-offTCS CONSTRUCTION CORP02/23/2021
DOB NOWPlumbingSigned-offDOUG'S PLBG & HTG SERV CO06/17/2020
BISOTISSUEDTCS CONSTRUCTION CORP08/18/2020
1 project · most recent 11/02/2020
General Wiring
FiledStatusContractorScope
11/02/2020CompleteFRIED ELECTRIC CO.General Wiring
▾Special Inspection Requirements (DOB NOW) — 6
DateRequirementInspectorRole
10/18/2021Fire-Resistant Penetrations and JointsJulian Saavedraspecial
10/18/2021Mechanical SystemsJulian Saavedraspecial
10/18/2021Energy Code Compliance InspectionsJulian Saavedraprogress
10/18/2021FinalJulian Saavedraprogress
10/18/2021HVAC and service water heating equipment Julian Saavedraenergy_progress
10/18/2021Maintenance informationJulian Saavedraenergy_progress
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch - Plumbing4
09/02/2026B00274599-I1Request digital key ↗
09/02/2026B00274599-P2Request digital key ↗
08/15/2026B00274599-P3Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/02/2026B00274617-I1Request digital key ↗
08/15/2026B00274617-P1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
10/07/2021322017009Open ↗
07/22/2021322017009Open ↗
12/10/2019322017009Open ↗
▸BISWORK PERMIT APPLICATION1
12/24/2019322017009Open ↗
▸Seals & Professional Certifications14
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026B00274599-I1Open ↗
08/13/2026B00274599-P1Open ↗
08/13/2026B00274617-P1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/02/2026B00274617-P1Open ↗
09/02/2026B00274617-P1Open ↗
09/02/2026B00274617-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/02/2026B00274617-P1Open ↗
09/02/2026B00274617-P1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/10/2019322017009Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/10/2019322017009Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/10/2019322017009Open ↗
▸Trade Schedules & Equipment2
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
11/11/2021322017009Open ↗
▸BISDETECTOR:CARBON MONOXIDE-CERT.OF INSTALL1
11/03/2021322017009Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
08/13/2026B00274599-P3Open ↗
08/13/2026B00274617-P1Open ↗
08/13/2026B00274599-P2Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/17/2019322017009Open ↗
▸Energy Compliance4
▸BISAS-BUILT ENERGY ANALYSIS1
11/05/2021322017009Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/05/2021322017009Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
11/03/2021322017009Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/10/2019322017009Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/05/2021322017009Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
11/15/2021322017009Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
11/05/2021322017009Open ↗
12/10/2019322017009Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
11/03/2021322017009Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
10/07/2021322017009Open ↗
▸BISEFILING COVER SHEET1
12/10/2019322017009Open ↗