ECB05/04/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: 2 OUT OF18 EXTERIOR FLOOD LIGHTS WORKING ONLY AT EXP #3 AND EXP #4 THE OTHER 16 NOT FUNCTIONING CAUSING NO ILLUMINATION FOR PEDESTRIAN WALKWAY AT EX$1K due
ECB05/04/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: CRACKED,MISSING AND LIFTING DIAMOND TREAD STRIPS AT EXPOSURE #1 WITH EXPOSED SCREWS AND A CHUNK OF CONCRETE OF STEP RISER TREAD STRIPS WITH EXPOSED$1K due
DOB01/13/1997V-DOB VIOLATION - ACTIVE
ECB05/04/2026REISSUE ON ECB#35719871K FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:WATER DAMAGE FROM WATER LEAK ON ACOUSTIC CEILING TILE IN ROOM 111 AND KITCHEN CEILING PAN TILES AND LENSE OF LINEAR LIGHT FIXNothing owed — awaiting certificate of correction
ECB05/04/2026REISSUE ON ECB#35719869L OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS.NOTED:PLAYGROUND/SCHOOL YARD OCCUPIED AND USED FOR PARKING AND OR PARKING LOT WITH 13 VNothing owed — awaiting certificate of correction
ECB05/04/2026EXIT DOOR NOT SELF-CLOSING.NOTED:EMERGENCY EXTERIOR EXIT DOOR NOT SELFCLOSING PROPERLY DUE TO BINDING,MISSING AND OR FAULTY HARDWARE ON EXTERIOR DOOR AT EXIT 4 1ST FL OBSERVED UPON INSPECTION.REM:REPAIR/REPLACENothing owed — awaiting certificate of correction
ECB05/04/2026REISSUE ON ECB#35719867H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT ROOF PARAPET PRIMETER WITH NO ROOF RAILING OR FALL PROTECTION NEEDED AT 42 INCH HEIGHT REQUIRED OBSERVED UPON INSPECTION.RNothing owed — awaiting certificate of correction
ECB05/04/2026REISSUE ON ECB#35719866X FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-381.NOTED:EMERGENCY ILLUMINATED EXIT DISCHARGES AND EXNothing owed — awaiting certificate of correction
ECB05/04/2026REISSUE ON ECB#35719868J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:FIRE RATED CLASSROOMS AND SMOKE DOORS NOT SELF-CLOSING PROPERLY DUE TO BINDING MISSING AND OR FAULTY HARDWARE ON CLASSROOMS 2Nothing owed — awaiting certificate of correction
ECB05/04/2026FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTED:CRACKED EXTERIOR WINDOW IN LIBRARY 2ND FLOOR OBSERVED UPON INSPECTION.REM:REPAIRAND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB05/04/2026REISSUE ON ECB#35719870Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:STORAGE IN ELECTRICAL SWITCH GEAR ROOM WITH DESK CHAIR WORK STATION,BOXES AND JANTORIAL EQUIPMENT OBSERVED UPON INSPECTION.RENothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE ECB #35688895X. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT ROOF PARAPET AREA WITH NO HEIGHT OF 42IN RAILS REQUIRED/PROVIDED. REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE ECB #35688893M. OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OFO OR DOB. NOTED: AT EXP 3 PLAYGROUND OCCUPIED/USED AS A PARKING LOT WITH APPROX 10 VEHICLES. REMEDY: DISCONTINUE ILLEGAL OCCUPANCY OR AMENDNothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE ECB #35688896H. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1; 27-542. NOTED: AT 2ND AND 1ST FLOORS EMERGNothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE ECB 35688897J. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. NOTED: AT RMS 210, 213, 111 AND KITCHEN WITH WATER DAMAGE STAINING TO CEILINGS. REMEDY: REPAIR AND/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB08/28/2025REISSUE ECB #35688894Y. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT ROOF BULKHEAD MISSING HARDWARE /PUBLIC BAR AND 2ND AND 1ST FLOORS CORRIDOR SMOKE DOORS MISSING/NONE THROUGHOUT AREAS. REMENothing owed — awaiting certificate of correction
ECB07/18/2025REISSUE ECB #35688892K. FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANTMANNER. NOTED: AT ELECTRICAL METER ROOM WITH VARIOUS MULTIPLE ITEMS STORED BOXES, BUCKETS, ETC... REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB09/23/2024FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:CEILING LEAK AT ROOM#210,213,STAIRCASE 6,ROOM#111,AND KITCHEN AREA.REM:MAKE NECESSARY REPAIRS.Nothing owed — awaiting certificate of correction
ECB09/23/2024REISSUE#35672264N OCCUPANCY CONTRARY TO THAT ALLOWED BY COFO OR DEPT OF BUILDING RECORDS.NOTED:AT THE PLAYGROUND 16 CARS OWE PARKED AT THE TIME OF INSPECTION.REM:DISCONTINUE ILLEGAL USE OR AMEND COFO.Nothing owed — awaiting certificate of correction
ECB09/23/2024REISSUE#35672262J FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.NOTED:AT ROOFTOP,PARAPET IS NOT IN HEIGHT OF 42"AS REQUIRED.REM:PROVIDE PARAPET/RAILING.Nothing owed — awaiting certificate of correction
ECB09/23/2024REISSUE#35672261H FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER.ILLUMINATION FOR EXITS,EXIT DISCHARGES AND PUBLIC CORRIDORS PER BC 1006.1;27-542.NOTED:AT 2ND FLOOR,STAIRCASE AND PUBLIC CORRIDOR EMERGENCNothing owed — awaiting certificate of correction
ECB09/23/2024REISSUE#35672263L NOTED:AT ROOF LEVEL BULKHEAD DOOR MISSING PANIC BAR AT FIRST FLOOR CORRIDOR SMOKE MISSING CLASSROOM 122,115,109,CAFETERIA AND KITCHEN EXTERIOR DOOR SELF CLOSING PROPERLY DUE TO DEFECTIVE HARDWNothing owed — awaiting certificate of correction
ECB09/23/2024REISSUE#3567267Z FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNERNOTED:AT ELECTRICAL ROOM AND ELECTRICAL CLOSET ROOM#103G WITH ILLEGAL STORAGE OF MISC.ITEMS.REM:REMOVE ILLEGAL STORAGE.Nothing owed — awaiting certificate of correction
ECB06/22/2023REISSUE#35665200Z FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. NOTE:OBSERVED AT ROOF LEVEL, PARAPET WALL DOES NOT MEET THE REQUIRED HEIGHT SPECIFICATIONS AND NO TYPE OF FALL PROTECTION IN PLACE. JEOPONothing owed — awaiting certificate of correction
ECB06/22/2023FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE: OBSERVED AT 1ST FL ELECTRICAL METER ROOM AND ELECTRICAL CLOSET/RM 103G HAVE EXCESSIVE AMOUNT OF CARDBOARD BOXES,PAINT,AND MISCELLANEOUS ITEMS BEING STNothing owed — awaiting certificate of correction
ECB06/22/2023OCCUPANCY CONTRARY TO THAT ALLOWED BY THE CERTIFICATE OF OCCUPANCY OR BUILDING DEPARTMENT RECORDS. NOTE: OBSERVED AT EXP 3/ REAR PLAYGROUND APPROX 20 ILLEGAL PARKING SPACES ON SCHOOL GROUNDS HAVE TAKEN OVER THENothing owed — awaiting certificate of correction
ECB06/22/2023REISSUE#35665203Y FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER: LACK OF EMERGENCY LIGHTING FOR EXITS, EXIT DISCHARGES, AND PUBLIC CORRIDORS PER BC 1006.1, 27-542. NOTE OBSERVED EMERGENCY AND/OR EXIT LINothing owed — awaiting certificate of correction
ECB06/22/2023REISSUE#35654673P FAILURE TO MAINTAIN BUILDING IN CODE COMPLAINT MANNER, NOTE: OBSERVED AT VARIOUS LOCATIONS OF THE OCCUPIED SCHOOL BUILDINGINTERIOR EXIT AND/OR EXIT ACCESS DOOR EXPLICITLY AT ROOF LEVEL STAIR 'Nothing owed — awaiting certificate of correction
ECB07/08/2022FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:OBSERVED:@ROOF LEVEL,PARAPET WALLS DONT MEET REQUIRED HT (42").CURRENTLY THE WAS ARE 13"H W/O FALL PROTECTION.REPAIR &OR REPLACENothing owed — awaiting certificate of correction
ECB07/08/2022FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:LACK OF EMERGENCY LIGHTING FOR EXITS,EXIT DISCHARGES&PUBLIC CORRIDORS PER BC1006.1;27-542.OBSERVED:@2FL STAIRCASE&PUBLIC CORRIDORS.EMERGENCY LIGHTING/SIGNS REQUINothing owed — awaiting certificate of correction
ECB07/08/2022REISSUE35584199X FAILURE TO MAINTAIN BLDG IN CODECOMPLIANT MANNER:OBSERVED:@1FL,CORRIDORS,KITCHEN MAIN ENTRANCE&NEAR TO DANCE STUDIO,SMOKE DOOR LEAVES REMOVED FROM FRAME.REPAIR &OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/27/2021REISSUED#35502113Y FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: AT 1ST & 2ND FL DOUBLE DOOR IN THE CORRIDORS(FIRE DOORS/SMOKE DOOR)ARE MISSING ON BOTH FLOOR. REMEDY: REPAIR &/OR REPLACE.Nothing owed — awaiting certificate of correction
ECB07/08/2020FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER. NOTED: OBSERVED AT 1ST FL-FIRE PROOF SELF CLOSING DOORS FOR THE CORRIDORS(SMOKE DOORS)BETWEEN ROOMS 122 & 123,& NEXT TO DANCE STUDIO & ROOM 144 BOTH SETS OFNothing owed — awaiting certificate of correction
ECB07/08/2020FAILURE TO MAINTAIN BLDG WALL(S) OR APPURTENANCES.NOTED:OBSERVED AT THE SOUTH & WEST ELEVATION-CRACKS AT THE CORNER OF BLDG,BULGING BRICKS NEAR PARAPET WALL ABOVE ELECTRICAL ROOM.ALSO STAIRS BY EXIT 5 MISSINGNothing owed — awaiting certificate of correction
ECB04/07/2010SEC 105.1 WORK W/O PERMIT. WORK NOTED: CONSTRUCTION APPROX: 200 LINER FEET OF SIDE FANCE AT COLOANE AVE SIDE OF POROP LOT, WITH PARTIAL COLLAPSED SECTION (INTO SIDE LOC) W/O OBTAIN NECESS APPROVAL/PERMIT FR DOBNothing owed — awaiting certificate of correction