ECB06/15/2026AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING, I OBSERVED GUARDRAILS PARTIALLY MISSING AND INADEQUATE AT ALL FLOORS, SOME PLACES HAVE ONLY HAVE DEBRIS NETTING, FAILURE TO PROVIDE AND MAINTAIN ADEQUATE$5K due
ECB05/20/2026BC 3304.8. FAILURE TO DRAIN CONSTRUCTION SITE OF STANDING WATER. AS NOTED: AT TIME OF INSPECTION AT AN ACTIVE JOBSITE OF A PROPOSED 5 STORY BUILDING ALREADY AT THE BULKHEAD LEVEL. OBSERVED APPROX 12 FOOT OF A G$2K due
ECB04/22/2026BC 3303.11.2 AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING WITH ALL TRADES ROOF LEVEL, I OBSERVED NO PERMANENT STAIRS IN PLACE FROM THE 1ST FLOOR TO THE 4 FLOOR. THIS CREATES A HAZARD FOR FIRST RESPOND$5K due
ECB04/22/2026AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING WITH ALL TRADES. I OBSERVED THAT THERE WERE INADEQUATE OVERHEAD PROTECTION FOR ADJACENT BUILDING BALCONY AND DRIVEWAY, CONCRETE RESIDUE FALLING ON BALCONY$10K due
ECB04/22/2026BC 3301.13.5 AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING WITH ALL TRADES. UPON REVIEW OF THE CONSTRUCTION SUPERINTENDENT LOG BOOK, SUPERINTENDENT # 028933 WAS SIGNING IN FOR MORE THAT 2 CONSECUTIVE W$5K due
ECB04/22/2026AT THE TIME OF MY INSPECTION OF A 5 STORY NEW BUILDING WITH ALL TRADES. UPON REVIEW OF THE APPROVED DOCUMENTS IT REVEAL THAT 2" STYROFOAM SHOULD BE INSTALLED BEHIND STAYFORMS AND THERE WERE NONE FROM THE 3 FLOO$2K due
ECB04/09/2026BC 3304.8. FAILURE TO DRAIN CONSTRUCTION SITE OF STANDING WATER. AS NOTED: AT TIME OF INSPECTION AT JOBSITE FOR A PROPOSED 5TH STORY BUILDING ALREADY AT THE 5TH FLOOR SLAB. OBSERVED APPROXIMATELY 47" OF GROUND$2K due
ECB03/24/2026FAILURE TO PROVIDE PROTECTION OF ADJOINING PROPERTY DURING CONSTRUCTION OR DEMOLITION AS REQUIRED-NO ROOF PROTECTION/ AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE 5 STORY BUILDING WORKING AT 4T$5K due
ECB03/24/2026FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES TEMPORARY CONSTRUCTION-NO GUARDRAILS. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE 5 STORY NEW BUILDING WORKING AT 4TH FLOOR. OBSERVED TH$5K due
ECB03/24/2026WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS. AS NOTED AT TIME OF INSPECTION ON ACTIVE CONSTRUCTION SITE, 5 STORY NEW BUILDING WORKING AT 4TH FLOOR. OBSERVED SHEAR WALLS S$620 due
ECB03/06/2026RESPONDENT FAILED TO PROVIDE BLIND SPOT MIRRORS FOR THE ADJOINING BUILDINGS ACTIVE DRIVEWAYS. B.C 3307.2.6. BOTH SIDES AT EXPO#2 AND #4 ARE MISSING MIRRORS TO PREVENT INJURY TO THE PUBLIC WHILE CROSSING IN FRON$5K due
DOB01/25/2012FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/02/2011FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB03/16/2010V-DOB VIOLATION - ACTIVE
DOB11/28/2007V-DOB VIOLATION - ACTIVE
ECB06/08/2026THE R-VALUE OF THE INSTALLED EXTERIOR WALLS OUTBOARD INSULATION AT EXPOSURE #4 IS R-VALUE 10 WITH THICKNESS 2" CONTRARY WITH THE APPROVED DOB EN DRAWING AND ARCHITECTURAL DRAWING THAT INDICATE R-VALUE 13.5., COHearing held — result not yet published$1K proposed
ECB03/24/2026FAILURE TO COMPLY EITH ASTMC 31 STANDARDS FOR CONCRETE CYLINDER TEST SAMPLES. AS NOTED AT TIME OF INSPECTION ON AN ACTIVE CONSTRUCTION SITE 5 STORY BUILDING. OBSERVED STRENGTH TEST CYLINDER MOLDED ON 03/17/2026Hearing held — result not yet published$2K proposed
ECB02/07/2017JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. NOTE: PLYWOOD CONSTRUCTION FENCE LEANING & BULGING OUT OVER UNTO SIDEWALK DECREASING WALKWAY. AT LEFT SIDE EXP#2 SIDE OF LOT. CONSTRUCTION PLYWOOD FENCE MINothing owed — awaiting certificate of correction
ECB11/21/2013JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. NOTED: CONSTRUCTION FENCE AT ABOVE LOCATION BROKEN/DAMAGED ALONG EXT #2. REMEDY: REPAIR/REPLACE.Nothing owed — awaiting certificate of correction
ECB03/20/2013NO PERMIT POSTED. NOTED: CONSTRUCTION FENCE IN PLACE AT ABOVE LOCATION. NO FN PERMIT POSTED. REMEDY: POST PERMIT.Nothing owed — awaiting certificate of correction
ECB01/16/2013JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION.NOTED:CONSTRUCTION FENCE IN PLACE @ABOVE LOCATION.ALL FENCE ALONG EXP.#2 BROKEN.REM:REPAIR OR REPLACE.Nothing owed — awaiting certificate of correction
ECB02/15/2012JOB SITE FENCE AT ABOVE LOCATION BROKEN IN 2 LOCATIONS. (EXPS 1 & 2). REMEDY: REPAIR/REPLACE FENCE.Nothing owed — awaiting certificate of correction
ECB12/29/2011JOB SITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION. NOTED:CONSTRUCTION FENCE AT ABOVE ADDRESS DAMAGED EXP 1 SITE ACCESSIBLE.REMEDY:REPAIRAND/OR REPLACE FENCE.Nothing owed — awaiting certificate of correction
ECB10/21/2011SEC. 105.8.2 EXPIRED PERMIT FOR TEMP CONST EQUIPMENT. NOTED: UPON INSPECTION FENCE PERMIT EXPIRED #301929983FN 12/31/05. REMEDY: RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB10/21/2011FAILURE TO MAINTAIN. NOTED: UPON INSPECTION FENCE COMING APART/MISSING AT EXPOSURE 1 DEBRIS ON SITE NOT REMOVED. REMEDY: REPAIR FENCE/REPLACE DEBRIS.Nothing owed — awaiting certificate of correction
ECB08/03/2011SEC. 105.8.2 EXPIRED PERMIT FOR TEMPORARY CONSTRUCTION EQUIPMENT. NOTED: UPON INSPECTION FENCE PERMIT EXPIRED. PERMIT #301929983FN 12/31/05.REMEDY: RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB08/03/2011FAILURE TO MAINTAIN. NOTED: UPON INSPECTION DEBRIS PILED ON SIDEWALK &BEHIND CONSTRUCTION FENCE/FENCE PANELS AT EXPOSURE 1 MISSING FENCE LOOSE & WEAK. REMEDY: REMOVE DEBRIS/REPAIR FENCE.Nothing owed — awaiting certificate of correction
ECB08/25/2009JOBSITE FENCE NOT CONSTRUCTED PURSUANT TO SUBSECTION BC3307-7 AND 27-1021C FOUND AT THE TIME OF INSP A 14'0" SECTION OF THE PERIMETER FENCE HAS COLLAPSED CREATING AN OPENING AND UNGUARDED OR UNRESTRICTED ACCESSNothing owed — awaiting certificate of correction
ECB02/17/2009WORK W/O A PERMIT.CONSTRUCTION FENCE INSTALLED W/O OBTAINING NECESSARYPERMIT. REMEDY:OBTAIN CONSTRUCTION FENCE PERMIT.Nothing owed — awaiting certificate of correction
ECB11/19/2007WORK W/O PERMIT EXPIRED PERMIT JOB SITE FENCE BUILT WITH APP. #301929983 HAS EXPIRED PERMIT ON 12/31/05.SITE SIZE APPROX.150FT X 150FT.REMEDY:RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB11/19/2007JOBSITE FENCE DEFECTIVE.NOTED:CONSTR. SITE 8FT HIGH PLYWOOD FENCE,1)ISNOT PLUMB-LEANING IN & OUTWARD 2)MISSING SECTIONS AT SEVERAL SPOTS & SITE IS WIDE OPEN.(AT 1445 W 5ST APPROX.35FT)DANGEROUS FOR PEOPLE FALLINothing owed — awaiting certificate of correction
ECB08/31/2007FAILURE TO SAFEGUARD PUBLIC&PROPERTY NOTED:JOBSITE INACTIVE UNDER APP#301929983 EXP 12/31/05.CONSTRUCTION FENCE AT NORTHSIDE APPROX 30' MISSING LEAVING SITE&PARTIAL EXCAVATION OPEN TO TRESPASSERS&CHILDREN OPENNothing owed — awaiting certificate of correction
ECB08/31/2007JOBSITE FENCE DEFECTIVE NOTED:UNDER APP#301929983 HAS EXPIRED 12/31/05 AT NORTHSIDE OF SITE APPROX 30' 8' HIGH FENCE IS MISSING LEAVING SITE AND PARTIAL EXCAVATION OPEN TO PUBLIC CREATING A HAZARDOUS CONDITIONNothing owed — awaiting certificate of correction
ECB03/05/2007WORK W/O A PERMIT.EXPIRED PERMIT NOTED:FENCE ERECTED AT CONSTRUCTED SITE APPROX 200FT WIDE BY 200 DEPTH & 8FT HIGH UNDER APPLICATION 330192 9883 HAS EXPIRED 12/31/05.REMEDY:RENEW PERMIT FORTHWITH.Nothing owed — awaiting certificate of correction