← Back
BuildNYC
Predominantly retail with other uses
145-12 JAMAICA AVENUE
QUEENS · Jamaica · BIN 4438704
💬 Discuss this project
1922Year Built
2Stories
K4Building Class
R7XZoning
8,094 sfGross Floor Area
5Units
Rent Stabilized0 Active ViolationsFDNY Report ↗
Predominantly retail with other uses · Owner of record: 14514 Jamaica · 4,470 sf lot · 1.81 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofStructural steel and power systemsUnder Construction9p · 1 filing · 15 docs
Floor 2Structural steel and power systemsUnder Construction10p · 1 filing · 15 docs
Floor 1Structural steel and power systemsUnder Construction14p · 2 filings · 20 docs
CellarStructural steel and power systemsUnder Construction14p · 2 filings · 20 docs
Site & exteriorTop Laundromat storefront awning installation1p · 1 filing · 2 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
107 N1st510/14/2026
14514 Jamaica403/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Gerald Caliendo510/13/2026
Chon Engineering508/10/2026
Leon Skvirsky PE106/05/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Chon Engineering403/21/2026
Building Brothers203/21/2026
Caliendo Architects103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Grand Construction and deGeneral Contractor707/08/2026
Paul Signsspecialty_contractor203/21/2026
Vintage HomesGeneral Contractor106/27/2026
I Do Plumbing & HeatingPlumbing106/28/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
City-Wide Testing416410/13/2026
Chon Engineering2454508/10/2026
AG Engineering8899106/05/2025
Building Lifecycle
All (57)Filed (11)Permit Issued (6)Signed Off (1)Violation (1)Inspection (1)Objection (8)Special Inspection (29)
10/13/2026
Filed — Alteration CO
Relocating existing bathroom and kitchen fixtures, plus adding new fixtures. 2nd floor work only.
Q01331962-S2
10/13/2026
Filed — Alteration CO
Relocating existing bathroom and kitchen fixtures, plus adding new fixtures. 2nd floor work only.
Q01331962-P1
10/13/2026
Filed — Alteration CO
Relocating existing bathroom and kitchen fixtures, plus adding new fixtures. 2nd floor work only.
Q01331962-P2
08/12/2026
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
08/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
08/10/2026
Filed — Alteration
TO BUILD COMMERCIAL LAUNDRY. WORK INCLUDE INSTALLATION OF CONCRETE PAD FOR WASHERS, SUPPORTING COLUMN AND STORE FRONT MODIFICATION.
Q01169571-P4
08/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
08/04/2026
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
06/23/2026
Permit issued — General Construction
Q01331962-I1-GC
04/23/2026
Objection resolved — Resolved
04/23/2026
Objection resolved — Resolved
04/23/2026
Objection resolved — Resolved
04/12/2026
Objection raised — Fire_Protection
04/12/2026
Objection resolved — Addressed
04/12/2026
Objection raised — Plumbing
04/12/2026
Objection raised — Inspections
04/12/2026
Objection raised — Cost
03/27/2026
Special inspection requirement — Fenestration air leakage
ELIAS RASABI
03/27/2026
Special inspection requirement — Lighting controls
ELIAS RASABI
03/27/2026
Special inspection requirement — Lighting in dwelling units
ELIAS RASABI
03/27/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
ELIAS RASABI
03/27/2026
Special inspection requirement — Air barrier - visual inspection
ELIAS RASABI
03/27/2026
Special inspection requirement — Fenestration areas
ELIAS RASABI
03/27/2026
Special inspection requirement — Interior lighting power
ELIAS RASABI
03/17/2026
Filed — Alteration CO
Relocating existing bathroom and kitchen fixtures, plus adding new fixtures. 2nd floor work only.
Q01331962-S1
03/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
ELIAS RASABI
03/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
12/12/2025
Filed — Alteration CO
Relocating existing bathroom and kitchen fixtures, plus adding new fixtures. 2nd floor work only.
Q01331962-I1
12/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ELIAS RASABI
12/12/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ELIAS RASABI
10/16/2025
Filed — Alteration
TO BUILD COMMERCIAL LAUNDRY. WORK INCLUDE INSTALLATION OF CONCRETE PAD FOR WASHERS, SUPPORTING COLUMN AND STORE FRONT MODIFICATION.
Q01169571-P1
09/02/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
09/02/2025
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
07/15/2025
Signed off — Alteration
INSTALL STOREFRONT AWNING WITH NON-ILLUMINATED COPY READING "TOP LAUNDROMAT". COPY NOT TO EXCEED 12 SQ FT TOTAL. NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q01231887-I1
06/20/2025
Permit issued — General Construction
Q01231887-I1-GC
06/05/2025
Filed — Alteration
INSTALL STOREFRONT AWNING WITH NON-ILLUMINATED COPY READING "TOP LAUNDROMAT". COPY NOT TO EXCEED 12 SQ FT TOTAL. NO CHANGE IN USE, EGRESS OR OCCUPANCY
Q01231887-I1
06/03/2025
Permit issued — General Construction
Q01169571-I1-GC
05/30/2025
Permit issued — General Construction
Q01169571-I1-GC
03/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/14/2025
Permit issued — Plumbing
Q01169571-S2-PL
03/10/2025
Filed — Alteration
TO BUILD COMMERCIAL LAUNDRY. WORK INCLUDE INSTALLATION OF CONCRETE PAD FOR WASHERS, SUPPORTING COLUMN AND STORE FRONT MODIFICATION.
Q01169571-S1
03/10/2025
Filed — Alteration
TO BUILD COMMERCIAL LAUNDRY. WORK INCLUDE INSTALLATION OF CONCRETE PAD FOR WASHERS, SUPPORTING COLUMN AND STORE FRONT MODIFICATION.
Q01169571-S2
03/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
Steve Chon
03/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
Steve Chon
03/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
Steve Chon
03/03/2025
Permit issued — General Construction
Q01169571-I1-GC
02/21/2025
Filed — Alteration
TO BUILD COMMERCIAL LAUNDRY. WORK INCLUDE INSTALLATION OF CONCRETE PAD FOR WASHERS, SUPPORTING COLUMN AND STORE FRONT MODIFICATION.
Q01169571-I1
01/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
Steve Chon
01/21/2025
Special inspection requirement — Mechanical Systems
Steve Chon
01/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
01/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Steve Chon
01/21/2025
Special inspection requirement — Fire-Resistance Rated Construction
Steve Chon
01/21/2025
Special inspection requirement — Final
Steve Chon
01/21/2025
Special inspection requirement — Tenant Protection Plan Compliance
Steve Chon
01/21/2025
Special inspection requirement — Final
Steve Chon
01/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Steve Chon
08/13/2017
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedVintage Homes06/23/2026
DOB NOWGeneral ConstructionSigned-offPaul Signs06/20/2025
DOB NOWGeneral ConstructionPermit IssuedGrand Construction and de06/03/2025
DOB NOWGeneral ConstructionPermit IssuedGrand Construction and de05/30/2025
DOB NOWPlumbingPermit IssuedI Do Plumbing & Heating03/14/2025
DOB NOWGeneral ConstructionPermit IssuedGrand Construction and de03/03/2025
BISOTISSUEDFuture Restoration12/05/2017
1 project · most recent 08/10/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/10/2026Permit IssuedGrand Construction and deHeating and Air Conditioning Systems
Heat / Cool
Daikin SS 15,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 08/10/2026
FiledStatusContractorScope
08/10/2026——48 heads
2 projects · most recent 10/13/2026
Gas Water/Sanitary Plumbing-Sprinkler
FiledStatusContractorScope
10/13/2026——Gas, Water/Sanitary
08/10/2026Permit IssuedI Do Plumbing & HeatingGas, Plumbing-Sprinkler, Water/Sanitary
2 projects · most recent 09/02/2026
General Wiring
FiledStatusContractorScope
09/02/2026Permit IssuedFalco Electrical ServicesGeneral Wiring
06/10/2026Permit IssuedFalco Electrical ServicesGeneral Wiring
▾Field Inspections (DOB CAP) — 1
DateTypeResultReport
03/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 29
DateRequirementInspectorRole
08/12/2026Energy Code Compliance InspectionsSteve Chonprogress
08/12/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
08/04/2026Fire-Resistant Penetrations and JointsSteve Chonspecial
08/04/2026Energy Code Compliance InspectionsSteve Chonprogress
03/27/2026Fenestration air leakageELIAS RASABIenergy_progress
03/27/2026Lighting controlsELIAS RASABIenergy_progress
03/27/2026Lighting in dwelling unitsELIAS RASABIenergy_progress
03/27/2026Fenestration and door U-factor and product ratingsELIAS RASABIenergy_progress
03/27/2026Air barrier - visual inspectionELIAS RASABIenergy_progress
03/27/2026Fenestration areasELIAS RASABIenergy_progress
03/27/2026Interior lighting powerELIAS RASABIenergy_progress
03/17/2026HVAC-R and service water piping design and insulationELIAS RASABIenergy_progress
03/17/2026Fire-Resistant Penetrations and JointsELIAS RASABIspecial
12/12/2025Fire-Resistant Penetrations and JointsELIAS RASABIspecial
12/12/2025Structural Stability – Alterations of existing buildingsELIAS RASABIspecial
09/02/2025Fire-Resistant Penetrations and JointsSteve Chonspecial
09/02/2025Energy Code Compliance InspectionsSteve Chonprogress
03/10/2025HVAC-R and service water piping design and insulationSteve Chonenergy_progress
03/10/2025HVAC-R and service water heating system controlsSteve Chonenergy_progress
03/10/2025HVAC-R and service water heating equipmentSteve Chonenergy_progress
01/21/2025Tenant Protection Plan ComplianceSteve Chonspecial
01/21/2025Mechanical SystemsSteve Chonspecial
01/21/2025Energy Code Compliance InspectionsSteve Chonprogress
01/21/2025Energy Code Compliance InspectionsSteve Chonprogress
01/21/2025Fire-Resistance Rated ConstructionSteve Chonprogress
Latest 25 of 29.
▾Documents — 88 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/20/2026Q01231887-I1Request digital key ↗
08/18/2026Q01169571-P4Request digital key ↗
08/18/2026Q01169571-P1Request digital key ↗
Showing 3 of 10 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION2
12/07/2017421581979Open ↗
04/28/2012420560397Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
05/24/2018421581979Open ↗
▸BISWORK PERMIT APPLICATION1
12/07/2017421581979Open ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/17/2026Q01331962-I1Open ↗
▸Seals & Professional Certifications47
▸DOB NOWProgress Inspector Seal & Signature19
10/03/2026Q01331962-S1Open ↗
09/30/2026Q01169571-P2Open ↗
09/30/2026Q01169571-P2Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature12
10/03/2026Q01331962-S1Open ↗
09/30/2026Q01169571-P2Open ↗
09/02/2026Q01331962-I1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/18/2026Q01169571-P4Open ↗
08/18/2026Q01169571-P3Open ↗
08/18/2026Q01169571-S2Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
12/07/2017421581979Open ↗
12/07/2017421581979Open ↗
12/07/2017421581979Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
05/24/2018421581979Open ↗
12/07/2017421581979Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/07/2017421581979Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/17/2026Q01331962-I1Open ↗
08/13/2026Q01331962-I1Open ↗
▸BISTenant Protection Plan and Notes1
12/07/2017421581979Open ↗
▸Environmental & Asbestos11
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/18/2026Q01169571-P4Open ↗
08/18/2026Q01169571-P3Open ↗
08/18/2026Q01169571-S2Open ↗
Showing 3 of 9 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/07/2017421581979Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
04/28/2012420560397Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/24/2018421581979Open ↗
12/07/2017421581979Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/24/2018421581979Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
05/24/2018421581979Open ↗
04/28/2012420560397Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
04/28/2012420560397Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
05/22/2018421581979Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/24/2018421581979Open ↗
12/07/2017421581979Open ↗
▸Filing & Intake Forms2
▸BISEFILING COVER SHEET2
12/07/2017421581979Open ↗
04/28/2012420560397Open ↗
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01331962-I1Open ↗