← Back
Cape Cod
145-43 130 AVENUE
QUEENS · Baisley Park · BIN 4262192
💬 Discuss this project
1945Year Built
1.5Stories
A0Building Class
R3AZoning
1,219 sfGross Floor Area
1Units
Cape Cod · Owner of record: AROUND 130 AVE INC. · 4,000 sf lot · 0.3 FAR built · Flood zone X500
Locations of Work
ArchitectureStructural
Floor 25p · 1 filing · 16 docs
Floor 15p · 1 filing · 16 docs
Cellar5p · 1 filing · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
BEESHAM CONSTRUCTION1107/11/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/06/2024$500K—Private party → RS CREATIVE CAPITAL GROUP INC.$410/sf building
08/06/2024$160K—RS CREATIVE CAPITAL GROUP INC. → AROUND 130 AVE INC.$131/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DUCTILE LLC307/04/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
R H DRUMMOND EXP603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINCITY ELECTRIC, INCElectrical103/22/2026
A-1 STATE INCGeneral Contractor104/09/2026
BEESHAM CONSTRUCTION INCGeneral Contractor104/09/2026
UNRESERVED MULTI SRVC LLCGeneral Contractor107/11/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DUCTILE CONSULTING INC.9349102/09/2025
Building Lifecycle
All (48)Filed (3)Permit Issued (4)Signed Off (2)Inspection (10)Objection (26)Special Inspection (3)
08/17/2026
Signed off — Alteration CO
Application filed to rear extension and conversion from one to two family with interior Remodeling & Renovation as required as per plan, A new C of O will be obtain.
Q01175900-S1
07/10/2026
Permit issued — Structural
Q01175900-I1-ST
05/12/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/23/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
04/22/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/15/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/15/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/12/2026
Signed off — Alteration
Install 8' height solid construction fence as per plan.
Q01161903-I1
12/08/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
10/22/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
07/28/2025
Permit issued — Plumbing
Q01175900-S1-PL
07/04/2025
Filed — Alteration CO
Application filed to rear extension and conversion from one to two family with interior Remodeling & Renovation as required as per plan, A new C of O will be obtain.
Q01175900-S1
07/02/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MANSUR AHMED
06/11/2025
Special inspection requirement — HVAC-R and service water heating equipment
MANSUR AHMED
06/11/2025
Special inspection requirement — HVAC-R and service water heating system controls
MANSUR AHMED
05/27/2025
Permit issued — General Construction
Q01175900-I1-GC
05/12/2025
Permit issued — Construction Fence
Q01161903-I1-FN
05/07/2025
Filed — Alteration
Install 8' height solid construction fence as per plan.
Q01161903-I1
04/22/2025
Objection resolved — Addressed
04/22/2025
Objection resolved — Addressed
04/14/2025
Objection raised — Energy
04/14/2025
Objection raised — Cost
04/01/2025
Objection resolved — Addressed
04/01/2025
Objection resolved — Addressed
04/01/2025
Objection resolved — Addressed
04/01/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
03/19/2025
Objection resolved — Addressed
02/21/2025
Objection raised — Admin
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Admin
02/21/2025
Objection raised — Zoning
02/21/2025
Objection raised — Energy
02/21/2025
Objection raised — Structural
02/21/2025
Objection raised — Scope
02/21/2025
Objection raised — Inspections
02/21/2025
Objection raised — Admin
02/21/2025
Objection raised — Structural
02/09/2025
Filed — Alteration CO
Application filed to rear extension and conversion from one to two family with interior Remodeling & Renovation as required as per plan, A new C of O will be obtain.
Q01175900-I1
10/31/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offUNRESERVED MULTI SRVC LLC07/10/2026
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR07/28/2025
DOB NOWGeneral ConstructionPermit IssuedA-1 STATE INC05/27/2025
DOB NOWConstruction FenceSigned-offBEESHAM CONSTRUCTION05/12/2025
1 project · most recent 07/04/2025
Gas Water/Sanitary
FiledStatusContractorScope
07/04/2025Signed-offINFINITI ESC PLUMBING CORGas, Water/Sanitary
1 project · most recent 05/20/2025
General Wiring
FiledStatusContractorScope
05/20/2025CompleteTRINCITY ELECTRIC, INCGeneral Wiring
1 project · most recent 07/04/2025
Wood
FiledStatusContractorScope
07/04/2025Signed-offUNRESERVED MULTI SRVC LLCWood
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
05/12/2026Pass-Final CND-Occupancy InspectionPassView ↗
04/23/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/22/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/15/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/15/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/15/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
12/08/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/22/2025Pass-Final CND-Occupancy InspectionPassView ↗
07/02/2025Pass-Final CND-Occupancy InspectionPassView ↗
10/31/2024Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
06/11/2025HVAC-R and service water piping design and insulationMANSUR AHMEDenergy_progress
06/11/2025HVAC-R and service water heating equipmentMANSUR AHMEDenergy_progress
06/11/2025HVAC-R and service water heating system controlsMANSUR AHMEDenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026Q01161903-I1Request digital key ↗
08/19/2026Q01175900-I1Request digital key ↗
08/19/2026Q01175900-S1Request digital key ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01175900-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q01175900-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWProgress Inspector Seal & Signature3
08/24/2026Q01175900-S1Open ↗
08/24/2026Q01175900-S1Open ↗
08/24/2026Q01175900-S1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q01175900-I1Open ↗
08/13/2026Q01175900-S1Open ↗
08/13/2026Q01161903-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01175900-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01175900-S1Open ↗
08/13/2026Q01175900-I1Open ↗
▸Other Documents4
▸DOB NOWProperty Ownership Certification1
08/13/2026Q01175900-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026Q01175900-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q01175900-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026Q01175900-I1Open ↗