← Back
BuildNYC
Two family frame
145-48 226 STREET
💬 Discuss this project
1960Year Built
2Stories
B2Building Class
R3-1Zoning
2,100 sfGross Floor Area
2Units
Rent Stabilized4 Open Violations ▸FDNY Report ↗
Two family frame · 2,813 sf lot · 0.75 FAR built · Flood zone X500
Locations of Work
Electrical
Roof1p · 1 filing · 9 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/22/2023$985K—Private party → Private party$469/sf building
09/29/2017$715K—— → —$340/sf building
03/16/2017$367K—— → —$175/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
PARKER AND WEST ENGINEERING, PLLC105/08/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUNRUN103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
SUNRUN INSTALLATION SVCGeneral Contractor203/21/2026
ISLAND ELECTRIC CORPElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
PARKER AND WEST ENGINEERI5272105/08/2024
Building Lifecycle
All (19)Filed (1)Permit Issued (1)Signed Off (1)Violation (11)Special Inspection (5)
11/25/2025
Violation issued (HPD, open)
I
08/05/2025
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01045628-I1
12/04/2024
Violation issued (HPD, open)
I
05/14/2024
Permit issued — Solar
Q01045628-I1-SL
05/08/2024
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q01045628-I1
05/03/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
05/03/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
05/03/2024
Special inspection requirement — Energy Code Compliance Inspections
Walid Abdulla
05/03/2024
Special inspection requirement — Final
Walid Abdulla
05/03/2024
Special inspection requirement — Air barrier - visual inspection
Walid Abdulla
11/18/2022
Violation issued (HPD, closed)
I
03/17/2022
Violation issued (HPD, closed)
I
04/22/2021
Violation issued (HPD, closed)
I
11/07/2019
Violation issued (HPD, closed)
I
01/08/2018
Violation issued (HPD, closed)
I
06/25/2007
Violation issued (HPD, closed)
B
06/25/2007
Violation issued (HPD, open)
B
06/25/2007
Violation issued (HPD, open)
C
07/22/2005
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSUNRUN INSTALLATION SVC05/14/2024
BISOTISSUEDPRO CUSTOM SOLAR LLC11/21/2019
2 projects · most recent 05/07/2024
FiledStatusContractorScope
05/07/2024CompleteSUNRUN SOLAR ELECTL CORP—
12/02/2019Permit IssuedISLAND ELECTRIC CORP—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
05/03/2024Fire-Resistant Penetrations and JointsWalid Abdullaspecial
05/03/2024Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
05/03/2024Energy Code Compliance InspectionsWalid Abdullaprogress
05/03/2024FinalWalid Abdullaprogress
05/03/2024Air barrier - visual inspectionWalid Abdullaenergy_progress
▾Documents — 30 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01045628-I1Request digital key ↗
▸Applications & Permits10
▸BISPLAN / WORK APPROVAL APPLICATION5
10/10/2023440575165Open ↗
08/25/2023440575165Open ↗
08/07/2023440575165Open ↗
Showing 3 of 5 on file for this type
▸BISApplication Withdrawal/Address Change Form OP-1134
10/10/2023440575165Open ↗
08/25/2023440575165Open ↗
08/25/2023440575165Open ↗
Showing 3 of 4 on file for this type
▸BISWORK PERMIT APPLICATION1
11/19/2019440575165Open ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature3
09/01/2026Q01045628-I1Open ↗
09/01/2026Q01045628-I1Open ↗
09/01/2026Q01045628-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
09/01/2026Q01045628-I1Open ↗
09/01/2026Q01045628-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
11/19/2019440575165Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
11/19/2019440575165Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
11/19/2019440575165Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01045628-I1Open ↗
▸Safety & Tenant Protection1
▸BISTENANT PROTECTION PLAN AND NOTES1
11/19/2019440575165Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/19/2019440575165Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01045628-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
11/19/2019440575165Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
11/19/2019440575165Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
11/19/2019440575165Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
11/19/2019440575165Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01045628-I1Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
11/19/2019440575165Open ↗
▸Filing & Intake Forms1
▸BISEFILING JOB APPLICATION COVER SHEET1
11/19/2019440575165Open ↗