← Back
Primarily 2 family with 1 store or office
145-48 ROCKAWAY BOULEVARD
QUEENS · Baisley Park · BIN 4261993
💬 Discuss this project
1930Year Built
2Stories
S2Building Class
R5DZoning
2,640 sfGross Floor Area
3Units
Primarily 2 family with 1 store or office · Owner of record: FU XING REALTY LLC · 2,023 sf lot · 1.3 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalGeneral
Filed — no permit issued29p · 2 filings · 16 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
FU LONG REALTY203/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/05/2015$465K—NYREB CAPITAL INC. → FU XING REALTY LLC$176/sf building
05/09/2014$360K—RETAINED REALTY, INC. → NYREB CAPITAL, INC.$136/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FANG ARCHITECT307/27/2023
Building Lifecycle
All (35)Filed (3)Objection (2)Special Inspection (30)
08/07/2023
Objection raised — Scope
08/07/2023
Objection raised — Admin
07/27/2023
Filed — Alteration
PROPOSED HORIZONTAL EXTENSION TO EXIST. LAUNDROMAT. NO CHANGE TO EXIST. USE, EGRESS, OR OCCUPANCY.
Q00836162-P1
07/21/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
07/21/2023
Special inspection requirement — Concrete - Cast-In-Place
07/21/2023
Special inspection requirement — Construction Operations Influencing Adjacent Structures
07/21/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
07/21/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
07/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/21/2023
Special inspection requirement — Masonry
07/21/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
07/21/2023
Special inspection requirement — Structural Steel - Details
07/21/2023
Special inspection requirement — Tenant Protection Plan Compliance
07/21/2023
Special inspection requirement — Energy Code Compliance Inspections
07/21/2023
Special inspection requirement — Final
07/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
07/21/2023
Special inspection requirement — Footing and Foundation
07/21/2023
Special inspection requirement — Fenestration air leakage
07/21/2023
Special inspection requirement — Fenestration areas
07/21/2023
Special inspection requirement — Lighting controls
07/21/2023
Special inspection requirement — Insulation placement and R values
07/21/2023
Special inspection requirement — Interior lighting power
07/21/2023
Special inspection requirement — Air barrier - visual inspection
07/20/2023
Filed — Alteration
INSTALL TEMP. CONSTRUCTION FENCE IN CONJUNCTION WITH JOB #Q00836162, #Q00836163.
Q00907268-I1
03/29/2023
Filed — Alteration
PROPOSED HORIZONTAL EXTENSION TO EXIST. LAUNDROMAT. NO CHANGE TO EXIST. USE, EGRESS, OR OCCUPANCY.
Q00836162-I1
03/29/2023
Special inspection requirement — Tenant Protection Plan Compliance
03/29/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
03/29/2023
Special inspection requirement — Lighting controls
03/29/2023
Special inspection requirement — Air barrier - visual inspection
03/29/2023
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
02/28/2023
Special inspection requirement — Structural Steel - Details
02/28/2023
Special inspection requirement — Final
02/28/2023
Special inspection requirement — Footing and Foundation
02/28/2023
Special inspection requirement — Energy Code Compliance Inspections
02/28/2023
Special inspection requirement — Fire-Resistance Rated Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDLIN'S ASSOCIATES INC06/06/2016
BISPLISSUEDCATMAN PLUMBING INC11/20/2015
BISEQISSUEDDEPENDABLE QUALITY11/20/2015
BISOTISSUEDDEPENDABLE QUALITY11/20/2015
1 project · most recent 07/27/2023
Steel Masonry
FiledStatusContractorScope
07/27/2023——Steel, Masonry
1 project · most recent 07/20/2023
Fence
FiledStatusContractorScope
07/20/2023——Fence
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
07/21/2023Fenestration and door U-factor and product ratings—energy_progress
07/21/2023Concrete - Cast-In-Place—special
07/21/2023Construction Operations Influencing Adjacent Structures—special
07/21/2023Excavations - Sheeting, Shoring, and Bracing—special
07/21/2023Exterior Insulation and Finish Systems (EIFS)—special
07/21/2023Fire-Resistant Penetrations and Joints—special
07/21/2023Masonry—special
07/21/2023Structural Stability – Alterations of existing buildings—special
07/21/2023Structural Steel - Details—special
07/21/2023Tenant Protection Plan Compliance—special
07/21/2023Energy Code Compliance Inspections—progress
07/21/2023Final—progress
07/21/2023Fire-Resistance Rated Construction—progress
07/21/2023Footing and Foundation—progress
07/21/2023Fenestration air leakage—energy_progress
07/21/2023Fenestration areas—energy_progress
07/21/2023Lighting controls—energy_progress
07/21/2023Insulation placement and R values—energy_progress
07/21/2023Interior lighting power—energy_progress
07/21/2023Air barrier - visual inspection—energy_progress
03/29/2023Tenant Protection Plan Compliance—special
03/29/2023Exterior Insulation and Finish Systems (EIFS)—special
03/29/2023Lighting controls—energy_progress
03/29/2023Air barrier - visual inspection—energy_progress
03/29/2023Excavations - Sheeting, Shoring, and Bracing—special
Latest 25 of 40.
▾Documents — 45 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/25/2026Q00836162-I1Request digital key ↗
08/24/2026Q00907268-I1Request digital key ↗
08/14/2026Q00836162-P1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
09/01/2016421221038Open ↗
08/22/2016421221038Open ↗
03/02/2016421221038Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION3
06/14/2016421221038Open ↗
11/28/2015421221038Open ↗
11/28/2015421221038Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
09/24/2016421221038Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00836162-P1Open ↗
08/13/2026Q00836162-I1Open ↗
▸Seals & Professional Certifications8
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
09/21/2016421221038Open ↗
10/17/2015421221038Open ↗
10/17/2015421221038Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/25/2026Q00836162-P1Open ↗
08/25/2026Q00836162-I1Open ↗
08/24/2026Q00907268-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
10/17/2015421221038Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/17/2015421221038Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE3
03/02/2016421221038Open ↗
02/26/2016421221038Open ↗
10/17/2015421221038Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026Q00836162-I1Open ↗
08/14/2026Q00836162-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
10/17/2015421221038Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
09/21/2016421221038Open ↗
10/17/2015421221038Open ↗
10/17/2015421221038Open ↗
▸BISAS-BUILT ENERGY ANALYSIS2
09/24/2016421221038Open ↗
09/21/2016421221038Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
09/24/2016421221038Open ↗
09/21/2016421221038Open ↗
▸BISSUPERSEDING LETTER1
06/14/2016421221038Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/21/2016421221038Open ↗
10/17/2015421221038Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
10/17/2015421221038Open ↗
▸Other Documents6
▸DOB NOWPlot Diagram2
08/13/2026Q00836162-P1Open ↗
08/13/2026Q00836162-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00836162-I1Open ↗
08/13/2026Q00836162-P1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00836162-I1Open ↗
08/13/2026Q00836162-P1Open ↗