← Back
Two family converted from one family
145-52 109 AVENUE
QUEENS · South Jamaica · BIN 4613970
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R4Zoning
2,946 sfGross Floor Area
2Units
Two family converted from one family · Owner of record: 14552 Z&L LLC · 4,000 sf lot · 0.74 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralCivilGeneral
Roof2p · 1 filing · 19 docs
Floor 11p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NOVELTY CONSTRUCTION1007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/27/2024$990K—— → —$336/sf building
12/15/2022$570K—— → —$193/sf building
10/20/2022$415K—— → —$141/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC308/10/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NASIR J. KHANZADA LLC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JIT CONSTR COMPANY CORPGeneral Contractor303/21/2026
NOVELTY CONSTRUCTION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC1527208/10/2023
Building Lifecycle
All (24)Filed (3)Permit Issued (2)Signed Off (1)Inspection (2)Objection (6)Special Inspection (10)
10/06/2023
Signed off — Alteration
PROPOSED NEW 10' CURB CUT ON 109 AVENUE FILED IN CONJUNCTION WITH NEW CAR GARAGE JOB # Q00866993-I1
Q00871796-I1
10/05/2023
Inspection — Pass-Final Curb Cut Non-Directive 14
Pass
View inspection ↗
09/08/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/10/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
ENLARGEMENT OF EXISTINGGARAGE AND TO OBTAINCERTIFICATE OF OCCUPANCY
Q00866993-P1
07/05/2023
Permit issued — Curb Cut
Q00871796-I1-CC
06/26/2023
Special inspection requirement — Concrete - Cast-In-Place
Nasir Khanzada
06/26/2023
Special inspection requirement — Masonry
Nasir Khanzada
06/26/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
06/26/2023
Special inspection requirement — Subgrade Inspections
Nasir Khanzada
06/26/2023
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
06/26/2023
Special inspection requirement — Final
Nasir Khanzada
06/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
Nasir Khanzada
06/26/2023
Special inspection requirement — Footing and Foundation
Nasir Khanzada
06/26/2023
Special inspection requirement — Interior lighting power
Nasir Khanzada
06/26/2023
Special inspection requirement — Exterior lighting power
Nasir Khanzada
06/13/2023
Permit issued — Foundation
Q00866993-I1-GC-CX
05/14/2023
Objection raised — Inspections
05/14/2023
Objection resolved — Addressed
05/14/2023
Objection raised — Scope
05/14/2023
Objection resolved — Addressed
05/10/2023
Filed — Alteration
PROPOSED NEW 10' CURB CUT ON 109 AVENUE FILED IN CONJUNCTION WITH NEW CAR GARAGE JOB # Q00866993-I1
Q00871796-I1
05/01/2023
Objection raised — Scope
05/01/2023
Objection resolved — Addressed
04/28/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
ENLARGEMENT OF EXISTINGGARAGE AND TO OBTAINCERTIFICATE OF OCCUPANCY
Q00866993-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWCurb CutSigned-offNOVELTY CONSTRUCTION CORP07/05/2023
DOB NOWFoundationPermit IssuedJIT CONSTR COMPANY CORP06/13/2023
1 project · most recent 08/10/2023
Concrete Masonry Wood
FiledStatusContractorScope
08/10/2023Permit IssuedJIT CONSTR COMPANY CORPConcrete, Masonry, Wood
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
10/05/2023Pass-Final Curb Cut Non-Directive 14PassView ↗
09/08/2023Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
06/26/2023Concrete - Cast-In-PlaceNasir Khanzadaspecial
06/26/2023MasonryNasir Khanzadaspecial
06/26/2023Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
06/26/2023Subgrade InspectionsNasir Khanzadaspecial
06/26/2023Energy Code Compliance InspectionsNasir Khanzadaprogress
06/26/2023FinalNasir Khanzadaprogress
06/26/2023Fire-Resistance Rated ConstructionNasir Khanzadaprogress
06/26/2023Footing and FoundationNasir Khanzadaprogress
06/26/2023Interior lighting powerNasir Khanzadaenergy_progress
06/26/2023Exterior lighting powerNasir Khanzadaenergy_progress
▾Documents — 21 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/24/2026Q00866993-P1Request digital key ↗
08/15/2026Q00871796-I1Request digital key ↗
08/15/2026Q00866993-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/13/2026Q00866993-P1Open ↗
08/13/2026Q00866993-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00866993-I1Open ↗
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026Q00866993-I1Open ↗
08/13/2026Q00871796-I1Open ↗
08/13/2026Q00866993-P1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/25/2026Q00866993-P1Open ↗
09/25/2026Q00866993-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/25/2026Q00866993-P1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00866993-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q00866993-I1Open ↗
▸Other Documents7
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/13/2026Q00866993-P1Open ↗
08/13/2026Q00866993-I1Open ↗
▸DOB NOWSite Survey: Initial2
08/13/2026Q00866993-I1Open ↗
08/13/2026Q00866993-P1Open ↗
▸DOB NOWProperty Ownership Certification2
08/13/2026Q00866993-P1Open ↗
08/13/2026Q00866993-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q00866993-I1Open ↗