DOB06/23/2024Failure to submit an eer per ad. Code sec. 28-308.4 - multiple years (2023)
DOB02/22/2024Failed to file FISP cycle 9C technical report by 2/21/2024
HPD09/23/2019§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD09/23/2019§ 27-2046.1 HMC: REPAIR OR REPLACE THE CARBON MONOXIDE DETECTING DEVICE(S). DEFECTIVE IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/16/2010SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/16/2010SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD10/16/2010SECTION 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILINGS AND WALLS IN THE ENTIRE APARTMENT LOCATED AT APT 3E, 3rd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD03/11/2010SECTION 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SCALDING HOT WATER IN THE ENTIRE APARTMENT LOCATED AT APT 2A, 2nd STORY, 1st APARTMENT FROM NORTH AT EAST
HPD04/11/2003SECTION 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR MISSING. IN THE ENTIRE APARTMENT LOCATED AT APT 9J, 9th STORY, 4th APARTMENT FROM EAST AT SOUTH
HPD05/23/2000SECTION 27-2005 ADM CODE REFIT WINDOWS UPER AND LOWER SASHES IN THE ENTIRE APARTMENT LOCATED AT APT 11C, 11th STORY, 7th APARTMENT FROM WEST AT NORTH
HPD05/23/2000SECTION 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WOODEN WINDOW FRAME IN THE 2nd ROOM FROM NORTH AT EAST LOCATED AT APT 11C, 11th STORY, 7th APARTMENT FROM WEST AT NORTH
ECB05/15/2019Mobile boiler in front of building no permit, obtain permitNothing owed — awaiting certificate of correction
ECB10/23/2017Failure to file annual certification that cooling tower 1000004212 hasbeen inspected,tested,and disinfected and that a maintenance plan has been developed and implemented by november,1,2016.rem:file annual certNothing owed — awaiting certificate of correction
ECB04/06/2007B4A,16,34A,50,50A,50B.50-both pressure controls piped to boiler on ONE1/4 pipe.50A-hot water pipe supported with rope.50B-fresh air louver falling out of boiler room wall.Nothing owed — awaiting certificate of correction
Old · issued 3+ years ago and still listed by DOB; nothing on the city's records either way
DOB04/22/2023Failure to submit an eer per ad. Code sec. 28-308.4 - multiple years (2022)Issued 2023; DOB's record still lists it as active
DOB08/21/2022Failure to submit an eer per ad. Code sec. 28-308.4 in 2021Issued 2022; DOB's record still lists it as active
DOB10/22/2021Elevator: elevatorrequired (DOB violation)Issued 2021; DOB's record still lists it as active
DOB05/02/2019Failure to file benchmarking report of energy use as per ad. Code sec. 28-309.4Issued 2019; DOB's record still lists it as active
DOB11/28/2018Elevator: elevatorrequired (DOB violation)Issued 2018; DOB's record still lists it as active