← Back
BuildNYC
One story - permanent living quarter
146-17 229TH STREET
QUEENS · BIN 4286449
💬 Discuss this project
1950Year Built
1Stories
A2Building Class
R3-1Zoning
1,050 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
One story - permanent living quarter · Owner of record: 108th Street Realty · 4,000 sf lot · 0.26 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralMechanicalPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof1p · 1 filing · 20 docs
Attic2p · 1 filing · 20 docs
Floor 25p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar6p · 1 filing · 20 docs
Site & exterior17p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
108 St Reakty1610/13/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Sion Consulting Engineering505/26/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Sion Consulting Engineering603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Yafe MeodGeneral Contractor204/09/2026
Power Surge ElectricElectrical103/22/2026
Yafe MeodScaffold104/09/2026
Infiniti Esc PlumbingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AA Building & Inspection1519405/26/2026
Building Lifecycle
All (103)Filed (5)Permit Issued (4)Violation (1)Inspection (5)Objection (58)Special Inspection (30)
08/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Younes Abouyaala
08/27/2026
Special inspection requirement — Structural Wood Frame
Younes Abouyaala
08/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
Younes Abouyaala
08/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
08/27/2026
Special inspection requirement — Final
NAVEEN KUMAR
08/27/2026
Special inspection requirement — Footing and Foundation
Younes Abouyaala
08/27/2026
Special inspection requirement — Mechanical Systems
Younes Abouyaala
08/27/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Younes Abouyaala
08/27/2026
Special inspection requirement — Heating Systems
Younes Abouyaala
08/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
08/27/2026
Special inspection requirement — Fenestration air leakage
Younes Abouyaala
08/27/2026
Special inspection requirement — Insulation placement and R values
Younes Abouyaala
08/27/2026
Special inspection requirement — Metering
Younes Abouyaala
08/27/2026
Special inspection requirement — Interior lighting power
Younes Abouyaala
08/27/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Younes Abouyaala
08/27/2026
Special inspection requirement — Ventilation and air distribution system
Younes Abouyaala
08/27/2026
Special inspection requirement — Maintenance information
Younes Abouyaala
08/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
08/27/2026
Special inspection requirement — Fenestration areas
Younes Abouyaala
08/27/2026
Special inspection requirement — Air barrier - visual inspection
Younes Abouyaala
08/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
08/27/2026
Special inspection requirement — Permanent certificate
Younes Abouyaala
08/27/2026
Special inspection requirement — Air barrier — testing
Younes Abouyaala
07/01/2026
Objection resolved — Resolved
06/30/2026
Objection resolved — Resolved
06/29/2026
Objection resolved — Addressed
06/29/2026
Objection resolved — Addressed
06/26/2026
Objection resolved — Resolved
06/25/2026
Objection raised — Admin
06/25/2026
Objection raised — Admin
06/25/2026
Objection raised — Admin
06/25/2026
Objection raised — Zoning
06/25/2026
Objection raised — Scope
06/08/2026
Inspection — Pass-Final Construction Permit Withdrawal
Pass
View inspection ↗
05/26/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
interior renovation, new second-floor extension, converting one family to two families residence, and obtaining COO
Q00932093-P2
05/26/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
interior renovation, new second-floor extension, converting one family to two families residence, and obtaining COO
Q00932093-P1
05/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Younes Abouyaala
05/20/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Younes Abouyaala
05/20/2026
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Younes Abouyaala
05/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Younes Abouyaala
05/20/2026
Special inspection requirement — HVAC-R and service water heating system controls
Younes Abouyaala
05/20/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Younes Abouyaala
05/20/2026
Special inspection requirement — Permanent certificate
Younes Abouyaala
09/18/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/18/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
09/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/03/2025
Permit issued — Plumbing
Q00932093-S1-PL
08/25/2025
Permit issued — Foundation
Q00932093-I1-GC-CX
03/13/2025
Violation issued (ECB, closed)
Construction
02/03/2025
Permit issued — Mechanical Systems
Q00932093-I1-GC-CX
09/27/2024
Permit issued — Construction Fence
Q00932093-S2-FN
08/28/2024
Objection resolved — Addressed
08/21/2024
Objection resolved — Addressed
08/21/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection resolved — Addressed
07/08/2024
Objection resolved — Addressed
06/17/2024
Objection resolved — Addressed
06/17/2024
Objection resolved — Addressed
Latest 60 of 103 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedInfiniti Esc Plumbing09/03/2025
DOB NOWFoundationPermit IssuedYafe Meod08/25/2025
DOB NOWMechanical SystemsPermit IssuedYafe Meod02/03/2025
DOB NOWConstruction FencePermit IssuedYafe Meod09/27/2024
1 project · most recent 05/26/2026
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
05/26/2026Permit IssuedYafe MeodHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Goodman GSX160421 126,000 BTU · Condensing Unit ×3
GM9C960603BN 60,000 BTU · Furnace ×2
Ventilation
Honeywell VNT5200E1000/U 200 CFM · Erv ×3
1 project · most recent 05/26/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/26/2026Permit IssuedInfiniti Esc PlumbingGas, Water/Sanitary
1 project · most recent 09/22/2025
General Wiring
FiledStatusContractorScope
09/22/2025CompletePower Surge ElectricGeneral Wiring
1 project · most recent 05/26/2026
Concrete Wood
FiledStatusContractorScope
05/26/2026Permit IssuedInfiniti Esc PlumbingConcrete, Wood
1 project · most recent 05/26/2026
Fence
FiledStatusContractorScope
05/26/2026Permit IssuedInfiniti Esc PlumbingFence
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
06/08/2026Pass-Final Construction Permit WithdrawalPassView ↗
09/18/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/18/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
09/18/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/18/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 56
DateRequirementInspectorRole
08/27/2026HVAC-R and service water heating equipmentYounes Abouyaalaenergy_progress
08/27/2026Structural Wood FrameYounes Abouyaalaprogress
08/27/2026Fire-Resistance Rated ConstructionYounes Abouyaalaprogress
08/27/2026Energy Code Compliance InspectionsYounes Abouyaalaprogress
08/27/2026FinalNAVEEN KUMARprogress
08/27/2026Footing and FoundationYounes Abouyaalaprogress
08/27/2026Mechanical SystemsYounes Abouyaalaspecial
08/27/2026Structural Stability – Alterations of existing buildingsYounes Abouyaalaspecial
08/27/2026Heating SystemsYounes Abouyaalaspecial
08/27/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
08/27/2026Fenestration air leakageYounes Abouyaalaenergy_progress
08/27/2026Insulation placement and R valuesYounes Abouyaalaenergy_progress
08/27/2026MeteringYounes Abouyaalaenergy_progress
08/27/2026Interior lighting powerYounes Abouyaalaenergy_progress
08/27/2026Fenestration and door U-factor and product ratingsYounes Abouyaalaenergy_progress
08/27/2026Ventilation and air distribution systemYounes Abouyaalaenergy_progress
08/27/2026Maintenance informationYounes Abouyaalaenergy_progress
08/27/2026HVAC-R and service water heating system controlsYounes Abouyaalaenergy_progress
08/27/2026Fenestration areasYounes Abouyaalaenergy_progress
08/27/2026Air barrier - visual inspectionYounes Abouyaalaenergy_progress
08/27/2026HVAC-R and service water piping design and insulationYounes Abouyaalaenergy_progress
08/27/2026Permanent certificateYounes Abouyaalaenergy_progress
08/27/2026Air barrier — testing Younes Abouyaalaenergy_progress
05/20/2026Fire-Resistant Penetrations and JointsYounes Abouyaalaspecial
05/20/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationYounes Abouyaalaspecial
Latest 25 of 56.
▾Documents — 44 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/22/2026Q00932093-S2Request digital key ↗
08/22/2026Q00932093-S1Request digital key ↗
08/22/2026Q00932093-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits1
▸BISPLAN / WORK APPROVAL APPLICATION1
03/11/2025421838998Open ↗
▸Zoning, Tax Lot & Property Records5
▸DOB NOWZD1: DOB Zoning Diagram2
08/14/2026Q00932093-P1Open ↗
08/13/2026Q00932093-I1Open ↗
▸BISTAX LOT: TENTATIVE LOT NUMBER ISSUED1
11/09/2023421838998Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00932093-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/14/2026Q00932093-P1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWProgress Inspector Seal & Signature8
08/29/2026Q00932093-I1Open ↗
08/29/2026Q00932093-I1Open ↗
08/29/2026Q00932093-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/22/2026Q00932093-I1Open ↗
08/22/2026Q00932093-S2Open ↗
08/22/2026Q00932093-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
08/29/2026Q00932093-I1Open ↗
08/25/2026Q00932093-P2Open ↗
08/24/2026Q00932093-P1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026Q00932093-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026Q00932093-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/22/2026Q00932093-S2Open ↗
08/22/2026Q00932093-S1Open ↗
08/22/2026Q00932093-I1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026Q00932093-I1Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
03/11/2025421838998Open ↗
▸Other Documents8
▸DOB NOWSite Survey: Initial2
08/14/2026Q00932093-P1Open ↗
08/13/2026Q00932093-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/14/2026Q00932093-P1Open ↗
08/13/2026Q00932093-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/22/2026Q00932093-I1Open ↗
08/14/2026Q00932093-P1Open ↗
▸BISPLOT DIAGRAM1
11/09/2023421838998Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
11/09/2023421838998Open ↗