← Back
BuildNYC
Two stories - detached, small or mid-size
146-26 20TH ROAD
QUEENS · BIN 4104885
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R3AZoning
1,618 sfGross Floor Area
1Units
0 Active ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: Reo Acquisitions · 2,500 sf lot · 0.65 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Roof6p · 1 filing · 19 docs
Attic8p · 1 filing · 19 docs
Floor 29p · 1 filing · 19 docs
Floor 18p · 1 filing · 19 docs
Cellar17p · 1 filing · 19 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Nguyen1007/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/31/2023$366K—Private party → REO ACQUISITIONS LLC$226/sf building
10/21/2020$750K—— → —$464/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Bild Architecture508/20/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Mark Hertz503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Water Works PipingPlumbing307/08/2026
Procraft Design & Cons CoGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Citiscape Consulting762208/20/2025
Building Lifecycle
All (90)Filed (5)Permit Issued (4)Signed Off (1)Violation (27)Inspection (4)Objection (46)Special Inspection (3)
10/24/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Joe Lieberman
10/23/2025
Objection resolved — Addressed
10/23/2025
Objection resolved — Addressed
09/20/2025
Objection raised — Plumbing
09/20/2025
Objection raised — Scope
08/20/2025
Filed — Alteration
Plumbing application to be filed in conjunction with GC application Q00909644-I1
Q00909644-P3
08/11/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/30/2025
Permit issued — Plumbing
Q00909644-S1-PL
04/24/2025
Permit issued — Plumbing
Q00909644-S1-PL
03/21/2025
Signed off — Alteration
Plumbing application to be filed in conjunction with GC application Q00909644-I1
Q00909644-I1
12/04/2024
Filed — Alteration
Plumbing application to be filed in conjunction with GC application Q00909644-I1
Q00909644-P2
12/04/2024
Special inspection requirement — Final
Joe Lieberman
07/29/2024
Objection raised — Scope
07/29/2024
Objection resolved — Addressed
07/29/2024
Objection raised — Zoning
07/29/2024
Objection resolved — Addressed
07/10/2024
Objection raised — Zoning
07/10/2024
Objection resolved — Addressed
07/01/2024
Filed — Alteration
Plumbing application to be filed in conjunction with GC application Q00909644-I1
Q00909644-P1
06/24/2024
Special inspection requirement — Final
Joe Lieberman
03/27/2024
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/08/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/08/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
02/29/2024
Permit issued — Plumbing
Q00909644-S1-PL
02/13/2024
Objection resolved — Addressed
02/13/2024
Objection resolved — Addressed
02/06/2024
Objection resolved — Addressed
01/29/2024
Objection resolved — Addressed
01/29/2024
Objection resolved — Addressed
01/29/2024
Objection resolved — Addressed
01/24/2024
Objection raised — Other
12/11/2023
Objection raised — Admin
12/11/2023
Objection raised — Inspections
12/11/2023
Objection raised — Admin
12/11/2023
Objection raised — Admin
12/11/2023
Objection raised — Fire_Protection
11/29/2023
Filed — Alteration
Plumbing application to be filed in conjunction with GC application Q00909644-I1
Q00909644-S1
11/02/2023
Permit issued — General Construction
Q00909644-I1-GC
10/16/2023
Violation issued (ECB, closed)
Construction
09/21/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/28/2023
Objection resolved — Addressed
08/02/2023
Objection raised — Structural
08/02/2023
Objection raised — Other
08/02/2023
Objection resolved — Addressed
08/02/2023
Objection raised — Fire_Protection
08/02/2023
Objection raised — Structural
08/02/2023
Objection raised — Scope
08/02/2023
Objection raised — Other
08/02/2023
Objection raised — Scope
08/02/2023
Objection raised — Inspections
08/02/2023
Objection raised — Admin
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedSuperior Piping & Mechanical07/30/2025
DOB NOWPlumbingPermit IssuedSuperior Piping & Mechanical04/24/2025
DOB NOWPlumbingPermit IssuedSuperior Piping & Mechanical02/29/2024
DOB NOWGeneral ConstructionSigned-offProcraft Design & Cons Co11/02/2023
1 project · most recent 08/20/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/20/2025Permit IssuedSuperior Piping & MechanicalGas, Water/Sanitary
1 project · most recent 03/14/2024
General Wiring
FiledStatusContractorScope
03/14/2024CompleteHeso ElectricalGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
08/11/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/27/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/08/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/08/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
10/24/2025Fire-Resistant Penetrations and JointsJoe Liebermanspecial
12/04/2024FinalJoe Liebermanprogress
06/24/2024FinalJoe Liebermanprogress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/21/2026Q00909644-P3Request digital key ↗
08/21/2026Q00909644-S1Request digital key ↗
08/21/2026Q00909644-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications8
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/21/2026Q00909644-P2Open ↗
08/21/2026Q00909644-P1Open ↗
08/21/2026Q00909644-S1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q00909644-P1Open ↗
08/24/2026Q00909644-P2Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/24/2026Q00909644-S1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/21/2026Q00909644-P2Open ↗
08/21/2026Q00909644-S1Open ↗
08/21/2026Q00909644-I1Open ↗
Showing 3 of 5 on file for this type