← Back
Two stories - detached, small or mid-size
146-29 20 ROAD
QUEENS · Whitestone-Beechhurst · BIN 4104868
💬 Discuss this project
1930Year Built
2.5Stories
A1Building Class
R3AZoning
1,761 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 2,904 sf lot · 0.61 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/23/2022$1.1M—Private party → Private party$625/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
MADRIAGA ENGINEERING P.C.311/13/2023
HUAN DESIGN INC.101/07/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JM CONSULTANT STUDIO603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LT PRO CONSTRUCTION INCGeneral Contractor303/21/2026
NY BUILDING ASSOCIATES INGeneral Contractor203/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HUAN DESIGN INC7669101/07/2023
Building Lifecycle
All (13)Filed (4)Permit Issued (2)Signed Off (2)Inspection (2)Special Inspection (3)
11/16/2023
Signed off — Alteration
EXTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REMOVE WOOD DECK, INSTALL NEW BRICK DECK AND PERMEABLE BRICK PAVER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00905867-I1
11/15/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
11/13/2023
Filed — Alteration
EXTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REMOVE WOOD DECK, INSTALL NEW BRICK DECK AND PERMEABLE BRICK PAVER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00905867-P2
11/13/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
10/31/2023
Filed — Alteration
EXTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REMOVE WOOD DECK, INSTALL NEW BRICK DECK AND PERMEABLE BRICK PAVER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00905867-P1
08/03/2023
Permit issued — General Construction
Q00905867-I1-GC
07/18/2023
Filed — Alteration
EXTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REMOVE WOOD DECK, INSTALL NEW BRICK DECK AND PERMEABLE BRICK PAVER AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00905867-I1
05/23/2023
Signed off — Alteration
INTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REPAIRING WALLS, CEILING, FLOOR, NEW DOORS AND PAINTING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00804346-I1
01/11/2023
Permit issued — General Construction
Q00804346-I1-GC
01/07/2023
Filed — Alteration
INTERIOR RENOVATION WORK OF 1-FAMILY BUILDING TO REPAIRING WALLS, CEILING, FLOOR, NEW DOORS AND PAINTING WORK AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00804346-I1
12/26/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ZHENHUAN XU
12/26/2022
Special inspection requirement — Final
ZHENHUAN XU
12/26/2022
Special inspection requirement — Energy Code Compliance Inspections
ZHENHUAN XU
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offLT PRO CONSTRUCTION INC08/03/2023
DOB NOWGeneral ConstructionSigned-offNY BUILDING ASSOCIATES IN01/11/2023
2 projects · most recent 09/13/2022
General Wiring
FiledStatusContractorScope
09/13/2022CompleteFUSION ELECTRIC, INC.1 meters, 1 new_meters
09/10/2022CompleteFUSION ELECTRIC, INC.General Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
11/15/2023Pass-Final General Construction Non-Directive 14PassView ↗
11/13/2023Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
12/26/2022Fire-Resistant Penetrations and JointsZHENHUAN XUspecial
12/26/2022FinalZHENHUAN XUprogress
12/26/2022Energy Code Compliance InspectionsZHENHUAN XUprogress
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/25/2026Q00804346-I1Request digital key ↗
08/24/2026Q00905867-P2Request digital key ↗
08/24/2026Q00905867-P1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications6
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/24/2026Q00905867-P1Open ↗
08/24/2026Q00905867-I1Open ↗
08/13/2026Q00804346-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/23/2026Q00804346-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026Q00804346-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q00804346-I1Open ↗