← Back
Professional building / stand-alone funeral home
Physicians & Surgeons Medical Building
1460 VICTORY BOULEVARD · Name © OpenStreetMap contributors · BIN 5016997
💬 Discuss this project
1980Year Built
2Stories
O7Building Class
R2Zoning
16,000 sfGross Floor Area
12Units
3 Open Violations 1 unresolved · 2 paperwork only ▸FDNY Report ↗
Professional building / stand-alone funeral home · 31,064 sf lot · 0.52 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalFire ProtectionGeneral
Cellar9p · 2 filings · 20 docs
1 job · most recent 06/03/2021
Water/Sanitary
FiledStatusContractorScope
06/03/2021Signed-offMPC PLUMBING & HEATING INWater/Sanitary
2 jobs · most recent 06/23/2023
General Wiring
FiledStatusContractorScope
06/23/2023CompleteFICHERA ELECTRIC, INCGeneral Wiring
06/09/2021CompleteN.Y. SOLAR ELECTRIC, INCGeneral Wiring
1 job · most recent 05/15/2024
Fence
FiledStatusContractorScope
05/15/2024Permit IssuedBUILDING CONCEPTS INCFence
Building Lifecycle
All (95)Filed (11)Permit Issued (11)Signed Off (6)Violation (24)Inspection (9)Objection (4)Special Inspection (30)
06/03/2025
Filed — Alteration
Stabilize Existing Gabion Wall which is leaning over on its existing retaining wall so as to resolve issued ECB Violation # 39119364L which was served on 03/30/2024 and related partial vacate order #S17/2024 issued 04/02/2024.
S01037763-P1
03/24/2025
Violation issued (ECB, open)
Construction
11/08/2024
Special inspection requirement — Concrete - Cast-In-Place
Nicholas Tamborra
11/08/2024
Special inspection requirement — Final
Ronald Victorio
11/08/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nicholas Tamborra
10/29/2024
Violation issued (ECB, closed)
Boilers
10/29/2024
Violation issued (ECB, closed)
Boilers
10/24/2024
Signed off — Alteration
HEREBY FILING INSTALLATION OF MECHANICAL EQUIPMENT AT SIDE YARD ON GRADE AS PER PLANS
S01089828-I1
09/17/2024
Permit issued — Mechanical Systems
S01089828-I1-MS
09/13/2024
Filed — Alteration
HEREBY FILING INSTALLATION OF MECHANICAL EQUIPMENT AT SIDE YARD ON GRADE AS PER PLANS
S01089828-I1
08/01/2024
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
08/01/2024
Special inspection requirement — Mechanical Systems
anthony santoro
08/01/2024
Special inspection requirement — Final
anthony santoro
08/01/2024
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
08/01/2024
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
08/01/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
06/25/2024
Permit issued — Construction Fence
S01051439-I1-FN
06/25/2024
Permit issued — General Construction
S01037763-I1-GC
06/12/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/22/2024
Objection raised — Structural
05/22/2024
Objection resolved — Addressed
05/22/2024
Objection raised — Structural
05/22/2024
Objection resolved — Addressed
05/15/2024
Filed — Alteration
INSTALL 8' HIGH CHAIN LINK CONSTRUCTION FENCE WITHIN EXISTING PROPERTY LINE FOR PROTECTION FROM EXISTING GABION WALL STABILIZATION SO AS TO RESOLVE PARTIAL VACATE ORDER #39110364L
S01051439-I1
05/15/2024
Filed — Alteration
Stabilize Existing Gabion Wall which is leaning over on its existing retaining wall so as to resolve issued ECB Violation # 39119364L which was served on 03/30/2024 and related partial vacate order #S17/2024 issued 04/02/2024.
S01037763-I1
03/30/2024
Violation issued (ECB, open)
Construction
03/30/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
12/08/2023
Signed off — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-S1
12/05/2023
Signed off — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-S2
12/04/2023
Signed off — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-I1
11/30/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
11/09/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
11/09/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/02/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/27/2023
Permit issued — Plumbing
S00866452-S2-EW-SP
10/27/2023
Permit issued — Plumbing
S00866452-S2-PL
09/18/2023
Signed off — Alteration
S00833544-I1
07/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/20/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/22/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/17/2023
Permit issued — Plumbing
S00866452-S2-PL
05/16/2023
Permit issued — Mechanical Systems
S00866452-S1-MS
05/15/2023
Filed — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-S2
05/15/2023
Permit issued — General Construction
S00866452-I1-GC
05/08/2023
Filed — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-S1
05/04/2023
Filed — Alteration
PLUMBING SUPPLY, WASTE AND VENT FOR TENANT BUILDOUT IN CELLAR. MODIFY EXISTING WET SPRINKLER FOR TENANT BUILDOUT IN CELLAR OFFICE. REPLACE ALL EXISTING PENDANT SPRINKLER HEADS IN TENANT AREA WITH CONCEALED PENDANT HEADS.
S00866452-I1
05/04/2023
Special inspection requirement — Sprinkler Systems
anthony santoro
05/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
05/04/2023
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
05/04/2023
Special inspection requirement — HVAC-R and service water heating equipment
anthony santoro
05/04/2023
Special inspection requirement — Maintenance information
anthony santoro
05/04/2023
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
05/04/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
05/04/2023
Special inspection requirement — Mechanical Systems
anthony santoro
05/04/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
anthony santoro
05/04/2023
Special inspection requirement — Energy Code Compliance Inspections
anthony santoro
05/04/2023
Special inspection requirement — Final
anthony santoro
05/04/2023
Special inspection requirement — HVAC-R and service water heating system controls
anthony santoro
05/04/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
anthony santoro
Latest 60 of 95 events.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TAMBORRA ARCHITECTURE. & CONSTRUCTI306/03/2025
KING ARCHITECT, PLLC109/13/2024
DAVID J DARCY, ARCHITECT405/15/2023
MS CONSULTANTS, INC.308/09/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CONSTRUCTION PERMIT SERVICES603/21/2026
JM ZONING, LLC.603/21/2026
DAVID J DARCY ARCHITECT403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JRB CONSTRUCTION CORPGeneral Contractor507/08/2026
BUILDING CONCEPTS INCGeneral Contractor307/08/2026
CLOVER MECHANICAL INCGeneral Contractor203/21/2026
CAPITAL CONTR P&H CORPPlumbing207/08/2026
CAPITAL CONTR P & H CORPFire Protection107/08/2026
MPC PLUMBING & HEATING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
TAMBORRA ARCHITECTURE5339206/03/2025
A TECH ENGINEERING NYC, P6738509/13/2024
WAYPOINT CONSULTING GROUP6175208/09/2021
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offBUILDING CONCEPTS INC09/17/2024
DOB NOWConstruction FencePermit IssuedBUILDING CONCEPTS INC06/25/2024
DOB NOWGeneral ConstructionPermit IssuedBUILDING CONCEPTS INC06/25/2024
DOB NOWPlumbingSigned-offCAPITAL CONTR P & H CORP10/27/2023
DOB NOWPlumbingSigned-offCAPITAL CONTR P&H CORP10/27/2023
DOB NOWPlumbingSigned-offCAPITAL CONTR P&H CORP05/17/2023
DOB NOWMechanical SystemsSigned-offJRB CONSTRUCTION CORP05/16/2023
DOB NOWGeneral ConstructionSigned-offJRB CONSTRUCTION CORP05/15/2023
DOB NOWGeneral ConstructionSigned-offJRB CONSTRUCTION CORP03/09/2023
DOB NOWMechanical SystemsSigned-offCLOVER MECHANICAL INC06/07/2021
DOB NOWPlumbingSigned-offMPC PLUMBING & HEATING IN06/04/2021
BISPLISSUEDEMPIRE PLUMBING INC08/05/2011
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
11/30/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
11/09/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
11/09/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/02/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
07/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/22/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/27/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/21/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/09/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
11/08/2024Concrete - Cast-In-PlaceNicholas Tamborraspecial
11/08/2024FinalRonald Victorioprogress
11/08/2024Structural Stability – Alterations of existing buildingsNicholas Tamborraspecial
08/01/2024HVAC-R and service water heating system controlsanthony santoroenergy_progress
08/01/2024Mechanical Systemsanthony santorospecial
08/01/2024Finalanthony santoroprogress
08/01/2024Energy Code Compliance Inspectionsanthony santoroprogress
08/01/2024HVAC-R and service water heating equipmentanthony santoroenergy_progress
08/01/2024HVAC-R and service water piping design and insulationanthony santoroenergy_progress
05/04/2023Sprinkler Systemsanthony santorospecial
05/04/2023Fire-Resistant Penetrations and Jointsanthony santorospecial
05/04/2023Energy Code Compliance Inspectionsanthony santoroprogress
05/04/2023HVAC-R and service water heating equipmentanthony santoroenergy_progress
05/04/2023Maintenance informationanthony santoroenergy_progress
05/04/2023HVAC-R and service water heating system controlsanthony santoroenergy_progress
05/04/2023HVAC-R and service water piping design and insulationanthony santoroenergy_progress
05/04/2023Mechanical Systemsanthony santorospecial
05/04/2023Fire-Resistant Penetrations and Jointsanthony santorospecial
05/04/2023Energy Code Compliance Inspectionsanthony santoroprogress
05/04/2023Finalanthony santoroprogress
05/04/2023HVAC-R and service water heating system controlsanthony santoroenergy_progress
05/04/2023HVAC-R and service water piping design and insulationanthony santoroenergy_progress
05/04/2023Shutoff dampersanthony santoroenergy_progress
05/04/2023Maintenance informationanthony santoroenergy_progress
05/04/2023HVAC-R and service water heating equipmentanthony santoroenergy_progress
Latest 25 of 34.
▾Documents — 77 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/25/2026S00530773-I1Request digital key ↗
08/25/2026S00530765-P2Request digital key ↗
08/25/2026S00530765-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits8
▸BISPLAN / WORK APPROVAL APPLICATION5
08/26/2021540198864Open ↗
08/23/2021540198864Open ↗
08/20/2021540198864Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION2
05/19/2021540198864Open ↗
08/08/2011520074071Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
09/08/2021540198864Open ↗
▸Seals & Professional Certifications35
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/25/2026S00530773-I1Open ↗
08/23/2026S00833544-I1Open ↗
08/23/2026S00866452-S1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/05/2026S00866452-I1Open ↗
09/05/2026S00866452-I1Open ↗
09/05/2026S00866452-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature7
09/05/2026S00866452-I1Open ↗
09/02/2026S00866452-S2Open ↗
08/28/2026S01089828-I1Open ↗
Showing 3 of 7 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
04/12/2021540198864Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
04/12/2021540198864Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
08/02/2011520074071Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
04/12/2021540198864Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
08/02/2011520074071Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
08/02/2011520074071Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
08/02/2011520074071Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/25/2026S00530773-I1Open ↗
08/23/2026S00833544-I1Open ↗
08/23/2026S00866452-S1Open ↗
Showing 3 of 7 on file for this type
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
05/19/2021540198864Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
04/12/2021540198864Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
04/12/2021540198864Open ↗
▸BISNYCECC ANALYSIS1
04/12/2021540198864Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/08/2021540198864Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
04/12/2021540198864Open ↗
▸Approvals, Objections & Sign-offs2
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/08/2021540198864Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
08/02/2011520074071Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT2
04/12/2021540198864Open ↗
08/02/2011520074071Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
09/08/2021540198864Open ↗
▸Filing & Intake Forms4
▸DOB NOWAI1 Form2
08/13/2026S00530765-I1Open ↗
08/13/2026S00530765-P2Open ↗
▸BISEFILING COVER SHEET1
08/02/2011520074071Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
04/12/2021540198864Open ↗