ECB08/07/20261) DEFECTIVE ZONE LOCK. 2) DAMAGED RETURN WALL. 3) IN-CAR COMMUNICATION INOPERATIVE (CEASE USE ITEMS).$1K due
DOB12/01/2021V-DOB VIOLATION - ACTIVE
DOB09/02/2020FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB04/05/2019VIOLATION ISSUED TO ELEVATOR - FAILURE TO FILE CATEGORY 1 2017 INSPECTION/TEST
DOB06/28/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/28/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/28/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/28/2017FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB01/03/2017VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2015 CAT 1 INSP/TST
DOB11/02/2016FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB06/10/2015VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2014 INSPECTION/TEST
DOB03/31/2014VIOLATION ISSUED TO ELEVATOR-FAILURE TO FILE CATEGORY 1 2012 INSPECTION/TEST
ECB03/09/2020OIL LEAK IN THE PIT REMOVE OIL. NO DOOR LOCK MONITORING INSTALLED IN THIS CONTROLLER AS MANDATED BY 3.10.12 OF APPENDIX K3 OF THE 2014 NYCBC. THIS IS A CONTROLLER FEATURE WHICH ENSURES PASSENGER SAFETY. FILE APNothing owed — awaiting certificate of correction
ECB04/06/2017FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. I OBSERVED IN COMMERCIAL LAUNDROMAT A WALL HUNG HEATING UNIT AND GAS DRYER NEXT TO IT WHICH IS BEING SHARED BY THE SAME GAS LINE BUT ONLY HAS ONE EMERGENCY SHUNothing owed — awaiting certificate of correction
ECB04/06/2017FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. RE: PROHIBITED INSTALLATION. I OBSERVED IN COMMERCIAL LAUNDROMAT ON WALL HUNG HEATINGUNIT A GAS FLEX CONNECTOR INSTALLED FROM GAS LINE TO HEATING UNIT SUPPNothing owed — awaiting certificate of correction
ECB04/06/2017WORK W/O PERMIT. I OBSERVED IN COMMERCIAL LAUNDROMAT AT THE BACK NEAR PARKING LOT A WALL HUNG HEATING UNIT WHICH HAD AN GAS FLEX ATTACHED FROM ONE SIDE OF GAS LINE TO THE UNIT ON WALL WITH A GAS SHUT OFF VALVNothing owed — awaiting certificate of correction
ECB04/06/2017FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. RE:PROHIBITED MATERIAL. I OBSERVED IN COMMERCIAL LAUNDROMAT A WALL HUNG HEATING UNITON GAS FLEX CONNECTOR ATTACHED FROM ONE SIDE TO GAS SHUT OFF VALVE TONothing owed — awaiting certificate of correction
ECB08/02/201605X10,10D06,40B07,40Z07,61R11,42O11,37Q03,CEASE USE ITEM:(05X)ZONE LOCK RESTRICTORS,BOTH ENTRANCES;(40B)PREVENT BLOCKAGE OF M.R.ENTRANCE;(40Z)REMOVE BLDG FIRE ALARM SYSTEM;(37Q)CAN BE OPENED WHERE PANEL IN;(42GNothing owed — awaiting certificate of correction
ECB03/10/201414J01,05X10,34Q03,34M07,71X10,70O02,40R09,69B11,61R11,48B10,48Y13,41W06,68M07,42M07,14-J ADJUST FOR PROPER VIEW OF CAB 25-X ZONE LOCK RESTRICTOR 34-Q SCREEN AT TOP OF HOIST (LOCKS) 34-M SMOKE HEAD 71-X LIGHT 70Nothing owed — awaiting certificate of correction