| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 09/22/2022 | $995K | — | — → — | $373/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| Momentum Solar | 1 | 01/16/2026 |
| Frank J Quatela Architects | 5 | 10/18/2023 |
| NYC Department of Housing Preservation and Development | 1 | 01/19/2023 |
| Representative | Filings | Most Recent |
|---|---|---|
| Build Assist Planning and Consulting | 10 | 03/21/2026 |
| Fire Building Code Services | 2 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| FK Construction | General Contractor | 4 | 03/21/2026 |
| Dno Equipment and Development | General Contractor | 3 | 03/21/2026 |
| D.D.S. Mechanical PBG & Heating | Plumbing | 3 | 07/08/2026 |
| Island Electric | Electrical | 1 | 03/22/2026 |
| Dno Equipment and Development | Scaffold | 1 | 07/08/2026 |
| DDS Mechanical FPS | Fire Protection | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| MXV Sia | 9281 | 1 | 01/16/2026 |
| Brian E. FLYNN, PE | 2837 | 2 | 10/18/2023 |
| Triangle Inspection & Tes | 7495 | 4 | 10/18/2023 |
| Fire and Building Code SE | 2128 | 1 | 01/19/2023 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Solar | Permit Issued | Momentum Solar | 01/20/2026 |
| DOB NOW | Plumbing | Signed-off | D.D.S. Mechanical PBG & Heating | 01/02/2024 |
| DOB NOW | Sprinklers | Signed-off | DDS Mechanical FPS | 04/25/2023 |
| DOB NOW | Structural | Permit Issued | FK Construction | 03/30/2023 |
| DOB NOW | Plumbing | Signed-off | D.D.S. Mechanical PBG & Heating | 01/04/2023 |
| DOB NOW | Foundation | Permit Issued | FK Construction | 12/13/2022 |
| DOB NOW | Plumbing | Signed-off | D.D.S. Mechanical PBG & Heating | 11/30/2022 |
| DOB NOW | Foundation | Permit Issued | Dno Equipment and Development | 11/20/2022 |
| DOB NOW | Construction Fence | Signed-off | Dno Equipment and Development | 10/27/2022 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 10/18/2023 | Permit Issued | FK Construction | Air Conditioning Systems, Ventilation Systems | Cooling Rheem RA13NZ48 4 tons · Condensing Unit ×4 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/18/2023 | Signed-off | D.D.S. Mechanical PBG & Heating | Gas, Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/16/2026 | Permit Issued | Island Electric | — |
| 06/29/2023 | Complete | Eastern Electrical Construction | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 10/18/2023 | Signed-off | D.D.S. Mechanical PBG & Heating | Wood |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 01/16/2026 | Permit Issued | Momentum Solar | 50 panels, 21.5 kw, 440 roof_area_sqft |
| Date | Type | Result | Report |
|---|---|---|---|
| 03/26/2024 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 10/11/2023 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 10/05/2023 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 04/28/2023 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 04/28/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 04/06/2023 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 10/16/2023 | Fire-Resistant Penetrations and Joints | Rajasekhar Sakhamuri | special |
| 10/16/2023 | Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation | Rajasekhar Sakhamuri | special |
| 10/16/2023 | Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities | BRIAN FLYNN | special |
| 10/16/2023 | Energy Code Compliance Inspections | Rajasekhar Sakhamuri | progress |
| 10/16/2023 | HVAC-R and service water heating equipment | Rajasekhar Sakhamuri | energy_progress |
| 10/16/2023 | HVAC-R and service water piping design and insulation | Rajasekhar Sakhamuri | energy_progress |
| 10/16/2023 | HVAC-R and service water heating system controls | Rajasekhar Sakhamuri | energy_progress |
| 10/16/2023 | Maintenance information | Rajasekhar Sakhamuri | energy_progress |
| 09/26/2023 | Concrete - Cast-In-Place | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Exterior Insulation and Finish Systems (EIFS) | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Fire-Resistant Penetrations and Joints | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Mechanical Systems | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Structural Stability – Alterations of existing buildings | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Subgrade Inspections | Rajasekhar Sakhamuri | special |
| 09/26/2023 | Subsurface Investigations (Borings/Test Pits) | BRIAN FLYNN | special |
| 09/26/2023 | Energy Code Compliance Inspections | Rajasekhar Sakhamuri | progress |
| 09/26/2023 | Final | Rajasekhar Sakhamuri | progress |
| 09/26/2023 | Fire-Resistance Rated Construction | Rajasekhar Sakhamuri | progress |
| 09/26/2023 | Footing and Foundation | Rajasekhar Sakhamuri | progress |
| 09/26/2023 | Structural Wood Frame | Rajasekhar Sakhamuri | progress |
| 09/26/2023 | Fenestration and door U-factor and product ratings | Rajasekhar Sakhamuri | energy_progress |
| 09/26/2023 | HVAC-R and service water heating system controls | Rajasekhar Sakhamuri | energy_progress |
| 09/26/2023 | Fenestration areas | Rajasekhar Sakhamuri | energy_progress |
| 09/26/2023 | Fireplaces | Rajasekhar Sakhamuri | energy_progress |
| 09/26/2023 | HVAC-R and service water piping design and insulation | Rajasekhar Sakhamuri | energy_progress |