← Back
BuildNYC
Two stories - detached, small or mid-size
147-14 5TH AVENUE
QUEENS · BIN 4101849
💬 Discuss this project
1945Year Built
2Stories
A1Building Class
R2AZoning
2,668 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,000 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalPlumbingFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofResidential solar electric generation array installation1p · 2 filings · 20 docs
Attic2p · 1 filing · 20 docs
Floor 210p · 2 filings · 20 docs
Floor 110p · 2 filings · 20 docs
Cellar14p · 2 filings · 20 docs
Site & exteriorErect construction fence to safeguard property1p · 1 filing · 2 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/22/2022$995K—— → —$373/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Build Assist Planning and Consulting1003/21/2026
Fire Building Code Services203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
FK ConstructionGeneral Contractor403/21/2026
Dno Equipment and DevelopmentGeneral Contractor303/21/2026
D.D.S. Mechanical PBG & HeatingPlumbing307/08/2026
Island ElectricElectrical103/22/2026
Dno Equipment and DevelopmentScaffold107/08/2026
DDS Mechanical FPSFire Protection107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
MXV Sia9281101/16/2026
Brian E. FLYNN, PE2837210/18/2023
Triangle Inspection & Tes7495410/18/2023
Fire and Building Code SE2128101/19/2023
Building Lifecycle
All (70)Filed (7)Permit Issued (9)Signed Off (2)Inspection (6)Objection (16)Special Inspection (30)
01/20/2026
Permit issued — Solar
Q01347383-I1-SL
01/16/2026
Filed — Alteration
Installation of solar panels, rooftop, grid tied, railed, 25 modules, 10.75 KW
Q01347383-I1
04/10/2024
Signed off — Alteration
Installation of Sprinkler System
Q08026817-I1
03/26/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/02/2024
Permit issued — Plumbing
Q00796799-S1-PL
10/18/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING IN CONJUNCTION WITH ALT 1 APPLICATION Q00796799
Q00796799-P3
10/16/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
BRIAN FLYNN
10/16/2023
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — HVAC-R and service water heating system controls
Rajasekhar Sakhamuri
10/16/2023
Special inspection requirement — Maintenance information
Rajasekhar Sakhamuri
10/11/2023
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
10/11/2023
Objection resolved — Addressed
10/05/2023
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/04/2023
Objection raised — Scope
10/02/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
FILING FOR PLUMBING IN CONJUNCTION WITH ALT 1 APPLICATION Q00796799
Q00796799-P1
09/26/2023
Signed off — Alteration
ERECT CONSTRUCTION FENCE TO SAFE GUARD PROPERTY IN CONJUNCTION WITH ALT1 APPLICATION Q00796799. NO CHANGE TO THE USE, EGRESS, AND OCCUPANCY.
Q00797619-I1
09/26/2023
Special inspection requirement — Concrete - Cast-In-Place
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Exterior Insulation and Finish Systems (EIFS)
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Mechanical Systems
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Structural Stability – Alterations of existing buildings
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Subgrade Inspections
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
BRIAN FLYNN
09/26/2023
Special inspection requirement — Energy Code Compliance Inspections
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Final
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Fire-Resistance Rated Construction
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Footing and Foundation
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Structural Wood Frame
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — HVAC-R and service water heating system controls
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Fenestration areas
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Fireplaces
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Air barrier - visual inspection
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Maintenance information
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — HVAC-R and service water heating equipment
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Insulation placement and R values
Rajasekhar Sakhamuri
09/26/2023
Special inspection requirement — Interior lighting power
Rajasekhar Sakhamuri
04/28/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/25/2023
Permit issued — Sprinklers
Q08026817-I1-EW-SP
04/06/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/30/2023
Permit issued — Structural
Q00796799-I1-GC-CX
01/25/2023
Objection raised — Admin
01/25/2023
Objection resolved — Addressed
01/25/2023
Objection raised — Structural
01/25/2023
Objection resolved — Addressed
01/25/2023
Objection raised — Structural
01/25/2023
Objection resolved — Addressed
01/25/2023
Objection raised — Scope
01/25/2023
Objection resolved — Addressed
01/25/2023
Objection raised — Admin
01/25/2023
Objection resolved — Addressed
01/19/2023
Filed — Alteration
Installation of Sprinkler System
Q08026817-I1
01/04/2023
Permit issued — Plumbing
Q00796799-S1-PL
12/13/2022
Permit issued — Foundation
Q00796799-I1-GC-CX
Latest 60 of 70 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedMomentum Solar01/20/2026
DOB NOWPlumbingSigned-offD.D.S. Mechanical PBG & Heating01/02/2024
DOB NOWSprinklersSigned-offDDS Mechanical FPS04/25/2023
DOB NOWStructuralPermit IssuedFK Construction03/30/2023
DOB NOWPlumbingSigned-offD.D.S. Mechanical PBG & Heating01/04/2023
DOB NOWFoundationPermit IssuedFK Construction12/13/2022
DOB NOWPlumbingSigned-offD.D.S. Mechanical PBG & Heating11/30/2022
DOB NOWFoundationPermit IssuedDno Equipment and Development11/20/2022
DOB NOWConstruction FenceSigned-offDno Equipment and Development10/27/2022
1 project · most recent 10/18/2023
Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
10/18/2023Permit IssuedFK ConstructionAir Conditioning Systems, Ventilation Systems
Cooling
Rheem RA13NZ48 4 tons · Condensing Unit ×4
1 project · most recent 10/18/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
10/18/2023Signed-offD.D.S. Mechanical PBG & HeatingGas, Storm, Water/Sanitary
2 projects · most recent 01/16/2026
General Wiring
FiledStatusContractorScope
01/16/2026Permit IssuedIsland Electric—
06/29/2023CompleteEastern Electrical ConstructionGeneral Wiring
1 project · most recent 10/18/2023
Wood
FiledStatusContractorScope
10/18/2023Signed-offD.D.S. Mechanical PBG & HeatingWood
1 project · most recent 01/16/2026
FiledStatusContractorScope
01/16/2026Permit IssuedMomentum Solar50 panels, 21.5 kw, 440 roof_area_sqft
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
03/26/2024Pass-Final CND-Occupancy InspectionPassView ↗
10/11/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
10/05/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
04/28/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
04/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
04/06/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
10/16/2023Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
10/16/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationRajasekhar Sakhamurispecial
10/16/2023Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesBRIAN FLYNNspecial
10/16/2023Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
10/16/2023HVAC-R and service water heating equipmentRajasekhar Sakhamurienergy_progress
10/16/2023HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
10/16/2023HVAC-R and service water heating system controlsRajasekhar Sakhamurienergy_progress
10/16/2023Maintenance informationRajasekhar Sakhamurienergy_progress
09/26/2023Concrete - Cast-In-PlaceRajasekhar Sakhamurispecial
09/26/2023Exterior Insulation and Finish Systems (EIFS)Rajasekhar Sakhamurispecial
09/26/2023Fire-Resistant Penetrations and JointsRajasekhar Sakhamurispecial
09/26/2023Mechanical SystemsRajasekhar Sakhamurispecial
09/26/2023Structural Stability – Alterations of existing buildingsRajasekhar Sakhamurispecial
09/26/2023Subgrade InspectionsRajasekhar Sakhamurispecial
09/26/2023Subsurface Investigations (Borings/Test Pits)BRIAN FLYNNspecial
09/26/2023Energy Code Compliance InspectionsRajasekhar Sakhamuriprogress
09/26/2023FinalRajasekhar Sakhamuriprogress
09/26/2023Fire-Resistance Rated ConstructionRajasekhar Sakhamuriprogress
09/26/2023Footing and FoundationRajasekhar Sakhamuriprogress
09/26/2023Structural Wood FrameRajasekhar Sakhamuriprogress
09/26/2023Fenestration and door U-factor and product ratingsRajasekhar Sakhamurienergy_progress
09/26/2023HVAC-R and service water heating system controlsRajasekhar Sakhamurienergy_progress
09/26/2023Fenestration areasRajasekhar Sakhamurienergy_progress
09/26/2023FireplacesRajasekhar Sakhamurienergy_progress
09/26/2023HVAC-R and service water piping design and insulationRajasekhar Sakhamurienergy_progress
Latest 25 of 38.
▾Documents — 120 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/25/2026Q00797619-I1Request digital key ↗
08/24/2026Q00796799-P3Request digital key ↗
08/24/2026Q00796799-I1Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits2
▸BISBPP-5 - Authorization to the Department of Transportation1
01/07/2023440743108Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/07/2023440743108Open ↗
▸Zoning, Tax Lot & Property Records4
▸DOB NOWZD1: DOB Zoning Diagram3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00796799-I1Open ↗
▸Seals & Professional Certifications78
▸DOB NOWProgress Inspector Seal & Signature51
09/01/2026Q00796799-P1Open ↗
09/01/2026Q00796799-P1Open ↗
09/01/2026Q00796799-P1Open ↗
Showing 3 of 51 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature17
09/01/2026Q00796799-P1Open ↗
09/01/2026Q00796799-P1Open ↗
09/01/2026Q00796799-P1Open ↗
Showing 3 of 17 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/25/2026Q08026817-I1Open ↗
08/24/2026Q00796799-I1Open ↗
08/24/2026Q00796799-S1Open ↗
Showing 3 of 8 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
01/07/2023440743108Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
01/07/2023440743108Open ↗
▸Trade Schedules & Equipment3
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸Safety & Tenant Protection2
▸BISBPP: STREET TREES SITE PLAN1
05/02/2023440743108Open ↗
▸BISSTREET TREE CHECKLIST1
05/02/2023440743108Open ↗
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/15/2026Q08026817-I1Open ↗
Showing 3 of 7 on file for this type
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00796799-I1Open ↗
▸Filing & Intake Forms2
▸BISEFILING JOB APPLICATION COVER SHEET1
01/07/2023440743108Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
01/07/2023440743108Open ↗
▸Other Documents10
▸DOB NOWSite Survey: Initial3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸DOB NOWProperty Ownership Certification3
08/24/2026Q00796799-I1Open ↗
08/15/2026Q00796799-P1Open ↗
08/13/2026Q00796799-P4Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
01/07/2023440743108Open ↗