← Back
Miscellaneous two family
147 23 STREET
BROOKLYN · Sunset Park (West) · BIN 3009415
💬 Discuss this project
1899Year Built
2Stories
B9Building Class
M1-2DZoning
1,530 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Miscellaneous two family · 1,720 sf lot · 0.89 FAR built · Flood zone X
Locations of Work
Architecture
Roof2p · 1 filing · 7 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC104/30/2025
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
L.S. ELECTRIC CORPElectrical103/22/2026
CENTURION SOLAR ENERGYGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854104/30/2025
Building Lifecycle
All (13)Filed (1)Permit Issued (1)Signed Off (1)Violation (1)Objection (4)Special Inspection (5)
10/14/2025
Signed off — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01218404-I1
05/29/2025
Permit issued — Solar
B01218404-I1-SL
05/21/2025
Objection resolved — Addressed
05/21/2025
Objection resolved — Addressed
05/15/2025
Objection raised — Mechanical
05/15/2025
Objection raised — Scope
04/30/2025
Filed — Alteration
SCOPE OF WORK IS SOLELY FOR THE INSTALLATION OF THE SOLAR ELECTRONICGENERATING SYSTEM. ALL OTHER WORK IS NOT TO BE RELIED UPON AS BEINGAPPROVED AND/OR PERMITTED BY THE NYC DEPARTMENT OF BUILDINGS.*NO CHANGE TO USE, EGRESS OR OCCUPANCY.*
B01218404-I1
04/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
04/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
TOM PETERSEN
04/30/2025
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
04/30/2025
Special inspection requirement — Final
TOM PETERSEN
04/30/2025
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
04/12/1989
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offCENTURION SOLAR ENERGY05/29/2025
2 projects · most recent 06/14/2025
FiledStatusContractorScope
06/14/2025CompleteBERGER QUALITY ELEC'L CON—
07/21/2023CompleteL.S. ELECTRIC CORP2 meters, 2 new_meters
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/30/2025Fire-Resistant Penetrations and JointsTOM PETERSENspecial
04/30/2025Structural Stability – Alterations of existing buildingsTOM PETERSENspecial
04/30/2025Energy Code Compliance InspectionsTOM PETERSENprogress
04/30/2025FinalTOM PETERSENprogress
04/30/2025Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 7 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/21/2026B01218404-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWProgress Inspector Seal & Signature2
08/23/2026B01218404-I1Open ↗
08/23/2026B01218404-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/21/2026B01218404-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/23/2026B01218404-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/21/2026B01218404-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026B01218404-I1Open ↗