← Back
One family attached or semi-detached
147-24 76 ROAD
QUEENS · BIN 4144548
💬 Discuss this project
1945Year Built
2Stories
A5Building Class
R4Zoning
1,224 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
One family attached or semi-detached · Owner of record: ARIEL REALTY HOLDINGS LLC · 2,825 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Floor 2Under Construction11p · 1 filing · 20 docs
Floor 1Under Construction12p · 1 filing · 20 docs
BasementUnder Construction40p · 1 filing · 20 docs
1 job · most recent 08/06/2026
FiledStatusContractorScope
08/06/2026Permit IssuedRRP PLUMBING CORP7 heads
1 job · most recent 05/15/2025
General Wiring
FiledStatusContractorScope
05/15/2025CompleteKJK ELECTRIC INCGeneral Wiring
1 job · most recent 08/06/2026
Steel
FiledStatusContractorScope
08/06/2026Permit IssuedRRP PLUMBING CORPSteel
1 job · most recent 08/06/2026
Fence
FiledStatusContractorScope
08/06/2026Permit IssuedRRP PLUMBING CORPFence
Building Lifecycle
All (72)Filed (9)Permit Issued (7)Signed Off (2)Violation (4)Inspection (6)Objection (14)Special Inspection (30)
09/03/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
08/06/2026
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-P4
07/23/2026
Signed off — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S2
07/22/2026
Permit issued — Sprinklers
Q01161268-S3-EW-SP
07/10/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/10/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/10/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
07/06/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
06/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
06/17/2026
Special inspection requirement — Maintenance information
GLEN LANGER
06/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
06/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
06/17/2026
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
06/17/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
05/19/2026
Signed off — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S4
05/19/2026
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-P3
05/19/2026
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-P2
05/19/2026
Special inspection requirement — Metering
GLEN LANGER
05/19/2026
Special inspection requirement — Permanent certificate
GLEN LANGER
05/19/2026
Special inspection requirement — Insulation placement and R values
GLEN LANGER
05/19/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
GLEN LANGER
05/19/2026
Special inspection requirement — Electric vehicle service equipment requirements
GLEN LANGER
05/19/2026
Special inspection requirement — Interior lighting power
GLEN LANGER
05/19/2026
Special inspection requirement — Fenestration areas
GLEN LANGER
05/19/2026
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
05/19/2026
Special inspection requirement — Air barrier - visual inspection
GLEN LANGER
05/19/2026
Special inspection requirement — Fenestration air leakage
GLEN LANGER
05/18/2026
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
05/18/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
05/18/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
05/18/2026
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
05/18/2026
Special inspection requirement — Maintenance information
GLEN LANGER
12/16/2025
Violation issued (ECB, closed)
Unknown
12/16/2025
Violation issued (ECB, closed)
Construction
11/07/2025
Permit issued — Plumbing
Q01161268-S5-PL
09/15/2025
Permit issued — Foundation
Q01161268-S1-FO
07/30/2025
Permit issued — Plumbing
Q01161268-S5-PL
07/17/2025
Permit issued — Structural
Q01161268-S2-ST
07/17/2025
Permit issued — General Construction
Q01161268-I1-GC
05/09/2025
Permit issued — Construction Fence
Q01161268-S4-FN
04/29/2025
Objection resolved — Addressed
04/29/2025
Objection resolved — Addressed
04/24/2025
Objection raised — Admin
04/24/2025
Objection raised — Admin
04/21/2025
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S3
04/11/2025
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S4
04/11/2025
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S5
04/10/2025
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S2
04/10/2025
Filed — Alteration CO
SPRINKLER SYSTEMS INSTALLATION IN CONJUNCTION WITH APPLICATION Q01161268-I1 TO CONVERT AN EXISTING ONE FAMILY DWELLING TO TWO FAMILY DWELLING WITH HORIZONTAL ENLARGEMENT AT BASEMENT FLOOR ONLY. THIS IS A HYDRAULICALLY CALCULATED SYSTEM.
Q01161268-S1
04/08/2025
Objection resolved — Addressed
04/03/2025
Special inspection requirement — Sprinkler Systems
GLEN LANGER
03/23/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
GLEN LANGER
03/22/2025
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
GLEN LANGER
03/22/2025
Special inspection requirement — Concrete - Cast-In-Place
GLEN LANGER
03/22/2025
Special inspection requirement — Subgrade Inspections
GLEN LANGER
03/22/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Rajasekhar Sakhamuri
Latest 60 of 72 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ARIEL REALTY HOLDING2409/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/17/2024$800K—Private party → ARIEL REALTY HOLDINGS LLC$654/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NOVUM ENGINEERING308/06/2026
AMINOV DESIGN ENGINEER, PC505/19/2026
TECC SOLUTIONS104/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A D BUILDING SOLUTIONS1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RISHON HOMES CORPGeneral Contractor407/08/2026
TRI STATE PLBG & HTG INCPlumbing207/08/2026
RRP PLUMBING CORPFire Protection107/23/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008608/06/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedRRP PLUMBING CORP07/22/2026
DOB NOWPlumbingPermit IssuedDW PLUMBING INC11/07/2025
DOB NOWFoundationPermit IssuedRISHON HOMES CORP09/15/2025
DOB NOWPlumbingPermit IssuedDW PLUMBING INC07/30/2025
DOB NOWStructuralSigned-offRISHON HOMES CORP07/17/2025
DOB NOWGeneral ConstructionPermit IssuedRISHON HOMES CORP07/17/2025
DOB NOWConstruction FenceSigned-offRISHON HOMES CORP05/09/2025
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
09/03/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/10/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/10/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/10/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
07/06/2026Pass-Final CND-Occupancy InspectionPassView ↗
▾Special Inspection Requirements (DOB NOW) — 32
DateRequirementInspectorRole
06/17/2026HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
06/17/2026HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
06/17/2026Maintenance informationGLEN LANGERenergy_progress
06/17/2026HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
06/17/2026Fire-Resistant Penetrations and JointsGLEN LANGERspecial
06/17/2026Energy Code Compliance InspectionsGLEN LANGERprogress
06/17/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
05/19/2026MeteringGLEN LANGERenergy_progress
05/19/2026Permanent certificateGLEN LANGERenergy_progress
05/19/2026Insulation placement and R valuesGLEN LANGERenergy_progress
05/19/2026Fenestration and door U-factor and product ratingsGLEN LANGERenergy_progress
05/19/2026Electric vehicle service equipment requirementsGLEN LANGERenergy_progress
05/19/2026Interior lighting powerGLEN LANGERenergy_progress
05/19/2026Fenestration areasGLEN LANGERenergy_progress
05/19/2026Energy Code Compliance InspectionsGLEN LANGERprogress
05/19/2026Air barrier - visual inspectionGLEN LANGERenergy_progress
05/19/2026Fenestration air leakageGLEN LANGERenergy_progress
05/18/2026Energy Code Compliance InspectionsGLEN LANGERprogress
05/18/2026Fire-Resistant Penetrations and JointsGLEN LANGERspecial
05/18/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
05/18/2026HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
05/18/2026HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
05/18/2026HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
05/18/2026Maintenance informationGLEN LANGERenergy_progress
04/03/2025Sprinkler SystemsGLEN LANGERspecial
Latest 25 of 32.
▾Documents — 61 on file (BIS + DOB NOW)
▸Plans & Drawings9
▸DOB NOWPlans/Sketch9
08/16/2026Q01161268-S3Request digital key ↗
08/16/2026Q01161268-P3Request digital key ↗
08/16/2026Q01161268-P2Request digital key ↗
Showing 3 of 9 on file for this type
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram2
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q01161268-I1Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/16/2026Q01161268-P4Open ↗
08/16/2026Q01161268-P3Open ↗
08/16/2026Q01161268-P2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026Q01161268-S1Open ↗
08/26/2026Q01161268-S5Open ↗
08/26/2026Q01161268-S5Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/02/2026Q01161268-S3Open ↗
09/01/2026Q01161268-S1Open ↗
09/01/2026Q01161268-S1Open ↗
Showing 3 of 6 on file for this type
▸Safety & Tenant Protection2
▸DOB NOWStreet Tree Checklist2
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/16/2026Q01161268-P4Open ↗
08/16/2026Q01161268-P3Open ↗
08/16/2026Q01161268-P2Open ↗
Showing 3 of 9 on file for this type
▸Inspections & Test Reports4
▸DOB NOWSOIL REPORT2
08/16/2026Q01161268-P4Open ↗
08/13/2026Q01161268-S1Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q01161268-S1Open ↗
▸DOB NOWGeotechnical Report (BC 1803.6)1
08/13/2026Q01161268-S1Open ↗
▸Other Documents10
▸DOB NOWPlot Diagram4
08/16/2026Q01161268-P4Open ↗
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSite Survey: Initial2
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗
▸DOB NOWProperty Ownership Certification2
08/16/2026Q01161268-P3Open ↗
08/13/2026Q01161268-I1Open ↗