← Back
BuildNYC
One story - permanent living quarter
147-55 JEWEL AVENUE
QUEENS · BIN 4143903
💬 Discuss this project
1945Year Built
1.5Stories
A2Building Class
R4AZoning
1,244 sfGross Floor Area
1Units
1 Active Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · 3,800 sf lot · 0.33 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingCivilGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofSolar panel installation on existing roof12p · 2 filings · 20 docs
Attic21p · 1 filing · 20 docs
Floor 230p · 2 filings · 20 docs
Floor 132p · 3 filings · 20 docs
Cellar40p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/08/2023$1.1M—Private party → Private party$880/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NY Building Associates103/23/2026
Haym S. Gross, Architect705/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Britz Enterprises803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Amar ConstructionGeneral Contractor203/21/2026
Crown PlumbingPlumbing207/08/2026
Amar Constructionspecialty_contractor203/21/2026
Amar ConstructionScaffold107/08/2026
Slal ConstructionScaffold104/09/2026
J Synergy Greenspecialty_contractor107/08/2026
Slal ConstructionGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NKM Engineering6244103/23/2026
Rike Tech Associates2965605/01/2025
Building Lifecycle
07/06/2026
Signed off — Alteration
INSTALLATION OF SOLAR PANELS ON EXISTING ROOF. NO CHANGE IN USE, OCCUPANCY, OR EGRESS. NO CHANGE IN BULK
Q01324663-I1
05/22/2026
Permit issued — Solar
Q01324663-I1-SL
04/29/2026
Signed off — Alteration
application filed for plumbing work
Q00990006-I1
04/23/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
04/14/2026
Signed off — Alteration
Q00984933-I1
70 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offJ Synergy Green05/22/2026
DOB NOWPlumbingSigned-offCrown Plumbing01/08/2026
DOB NOWGeneral ConstructionPermit IssuedSlal Construction07/09/2025
DOB NOWConstruction FenceSigned-offSlal Construction07/09/2025
DOB NOWEarth WorkPermit IssuedAmar Construction05/13/2025
DOB NOWPlumbingSigned-offCrown Plumbing10/03/2024
DOB NOWMechanical SystemsPermit IssuedAmar Construction08/23/2024
DOB NOWConstruction FenceSigned-offAmar Construction08/01/2024
1 project · most recent 02/11/2025
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScope
02/11/2025Permit IssuedSlal ConstructionAir Conditioning Systems, Heating Systems, Ventilation Systems
1 project · most recent 02/19/2026
General Wiring
FiledStatusContractorScope
02/19/2026CompleteGreen Light Electrical & MechanicalGeneral Wiring
1 project · most recent 02/11/2025
Steel Concrete Wood
FiledStatusContractorScope
02/11/2025Permit IssuedSlal ConstructionSteel, Concrete, Wood
1 project · most recent 03/23/2026
FiledStatusContractorScope
03/23/2026Signed-offJ Synergy Green—
1 project · most recent 02/11/2025
Earthwork
FiledStatusContractorScope
02/11/2025Permit IssuedSlal ConstructionEarthwork
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
04/23/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/09/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/11/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/28/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/11/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 105
DateRequirementInspectorRole
11/25/2025Air barrier - visual inspectionNARESH MAHANGUenergy_progress
11/25/2025FinalNARESH MAHANGUprogress
11/25/2025Energy Code Compliance InspectionsNARESH MAHANGUprogress
11/25/2025Structural Stability – Alterations of existing buildingsNARESH MAHANGUspecial
11/25/2025Fire-Resistant Penetrations and JointsNARESH MAHANGUspecial
04/02/2025Subgrade InspectionsSYED RIZVIspecial
04/02/2025Fire-Resistant Penetrations and JointsSYED RIZVIspecial
04/02/2025Mechanical SystemsSYED RIZVIspecial
04/02/2025Chimneys and ventsSYED RIZVIspecial
04/02/2025Structural Stability – Alterations of existing buildingsSYED RIZVIspecial
04/02/2025Concrete - Cast-In-PlaceSYED RIZVIspecial
04/02/2025Excavations - Sheeting, Shoring, and BracingSYED RIZVIspecial
04/02/2025Structural Wood FrameSYED RIZVIprogress
04/02/2025Footing and FoundationSYED RIZVIprogress
04/02/2025Fire-Resistance Rated ConstructionSYED RIZVIprogress
04/02/2025FinalHAYM GROSSprogress
04/02/2025Energy Code Compliance InspectionsSYED RIZVIprogress
04/02/2025Air barrier - visual inspectionSYED RIZVIenergy_progress
04/02/2025Electric vehicle service equipment requirementsSYED RIZVIenergy_progress
04/02/2025Heating SystemsSYED RIZVIspecial
04/02/2025Air barrier — testing SYED RIZVIenergy_progress
04/02/2025Permanent certificateSYED RIZVIenergy_progress
04/02/2025Fenestration areasSYED RIZVIenergy_progress
04/02/2025HVAC-R and service water heating equipmentSYED RIZVIenergy_progress
04/02/2025Insulation placement and R valuesSYED RIZVIenergy_progress
Latest 25 of 105.