← Back
BuildNYC
Two family converted from one family
147 DEISIUS STREET
STATEN ISLAND · BIN 5126333
💬 Discuss this project
1930Year Built
2Stories
B3Building Class
R3XZoning
—Gross Floor Area
2Units
Two family converted from one family · 0.63 FAR built · Flood zone X
Locations of Work
Electrical
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofPhotovoltaic solar panel installation1p · 1 filing · 9 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Parker and West Engineering103/24/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Sunrun103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Jeffery BarattaGeneral Contractor203/21/2026
Sunrun Installation Servicespecialty_contractor203/21/2026
Charles J. Dehart JR P&HPlumbing106/14/2017
Sunrun Installation ServiceGeneral Contractor109/27/2017
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Parker and West Engineering5272103/24/2025
Building Lifecycle
10/01/2025
Signed off — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01196314-I1
03/27/2025
Permit issued — Solar
S01196314-I1-SL
03/24/2025
Filed — Alteration
FILING HEREWITH TAX ABATEMENT APPLICATION FOR INSTALLATION OF ROOF MOUNTED SOLAR PANELS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
S01196314-I1
03/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Walid Abdulla
03/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Walid Abdulla
8 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offSunrun Installation Service03/27/2025
BISOTISSUEDSunrun Installation Service09/27/2017
BISPLISSUEDCharles J. Dehart JR P&H06/14/2017
BISEQISSUEDJeffery Baratta03/27/2017
BISOTISSUEDJeffery Baratta03/27/2017
1 project · most recent 03/21/2025
FiledStatusContractorScope
03/21/2025CompleteSunrun Solar Electl—
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
03/17/2025Fire-Resistant Penetrations and JointsWalid Abdullaspecial
03/17/2025Structural Stability – Alterations of existing buildingsWalid Abdullaspecial
03/17/2025Energy Code Compliance InspectionsWalid Abdullaprogress
03/17/2025FinalWalid Abdullaprogress
03/17/2025Air barrier - visual inspectionWalid Abdullaenergy_progress
74 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account