Rent Stabilized10 Open Violations ▸FDNY Report ↗
Five to six families · Owner of record: 147 PENN ST LLC · 2,225 sf lot · 1.35 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire ProtectionGeneral
Roof34p · 1 filing · 20 docs
Floor 437p · 1 filing · 20 docs
Floor 334p · 1 filing · 20 docs
Floor 233p · 1 filing · 20 docs
Floor 134p · 1 filing · 20 docs
Mezzanine36p · 1 filing · 20 docs
Cellar42p · 1 filing · 20 docs
1 job · most recent 12/06/2024
Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
12/06/2024Signed-offCREATIVE BUILDERS& DEVEL*Heating Systems, Ventilation Systems
Heating
Mitsubishi Electric MXZ-SM48NAM2-U1 MXZ-SM60NAM2-U1 66,000 BTU · Condensing Unit ×3
PUHY-EP120TNU-A PURY-EP120TNU-A1 160,000 BTU · Condensing Unit ×2
PUHY-9120TNU-A, PURY-P120TNU 66,000 BTU · Condensing Unit ×3
MXZ-SM48NAM2-U1 160,000 BTU · Condensing Unit ×2
Ventilation
Greenheck G-098-VG 650 CFM · Exhaust Fan ×2
1 job · most recent 12/06/2024
Sprinkler System
FiledStatusContractorScope
12/06/2024Signed-offTARGET PIPING NY LLCSprinkler System
1 job · most recent 12/06/2024
Gas Storm Water/Sanitary
FiledStatusContractorScope
12/06/2024Signed-offB&B MECH PLBG & HTG LLCGas, Storm, Water/Sanitary
4 jobs · most recent 10/15/2024
FiledStatusContractorScope
10/15/2024CompleteHIGH STANDARD ELECTRIC4 meters, 4 new_meters
12/08/2023CompleteSOLAS ELECTRICAL CORP—
11/02/2022CompleteHIGH STANDARD ELECTRIC4 meters, 4 new_meters
09/19/2022CompleteHIGH STANDARD ELECTRIC—
1 job · most recent 12/06/2024
Steel
FiledStatusContractorScope
12/06/2024Signed-offCREATIVE BUILDERS& DEVEL*Steel
Building Lifecycle
All (213)Filed (19)Permit Issued (17)Signed Off (9)Violation (50)Inspection (8)Objection (80)Special Inspection (30)
11/14/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/05/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
02/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/30/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
01/16/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S1
01/15/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S2
01/14/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
01/10/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S4
01/09/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S6
01/09/2025
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S5
01/08/2025
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
01/07/2025
Signed off — Alteration
B00762756-I1
12/23/2024
Signed off — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-S3
12/20/2024
Permit issued — Mechanical Systems
B00698785-S1-MS
12/20/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/18/2024
Special inspection requirement — Duct leakage testing, insulation and design
FAHAD FATEH
12/18/2024
Special inspection requirement — HVAC-R and service water heating system controls
FAHAD FATEH
12/18/2024
Special inspection requirement — Heating Systems
FAHAD FATEH
12/18/2024
Special inspection requirement — Shutoff dampers
FAHAD FATEH
12/18/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
FAHAD FATEH
12/18/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
12/18/2024
Special inspection requirement — Energy Code Compliance Inspections
FAHAD FATEH
12/18/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
FAHAD FATEH
12/18/2024
Special inspection requirement — Mechanical Systems
FAHAD FATEH
12/18/2024
Special inspection requirement — Maintenance information
FAHAD FATEH
12/18/2024
Special inspection requirement — HVAC-R and service water heating equipment
FAHAD FATEH
12/18/2024
Special inspection requirement — Electrical motors and elevators
FAHAD FATEH
12/18/2024
Special inspection requirement — Final
FAHAD FATEH
12/16/2024
Signed off — Alteration
B00763448-I1
12/16/2024
Objection resolved — Addressed
12/10/2024
Permit issued — Foundation
B00698785-S4-FO-EA
12/10/2024
Permit issued — Structural
B00698785-S3-ST
12/10/2024
Permit issued — Support of Excavation
B00698785-S5-SE
12/10/2024
Objection raised — Scope
12/09/2024
Special inspection requirement — Final
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Cold-Formed Steel
FAHAD FATEH
12/09/2024
Special inspection requirement — Final
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
12/09/2024
Special inspection requirement — Footing and Foundation
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
12/09/2024
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
FAHAD FATEH
12/09/2024
Special inspection requirement — Post-installed Anchors
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
12/09/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
FAHAD FATEH
12/06/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-P8
12/06/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-P7
12/06/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-A1
12/06/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-P9
12/06/2024
Special inspection requirement — Subgrade Inspections
FAHAD FATEH
12/06/2024
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
FAHAD FATEH
12/06/2024
Special inspection requirement — Structural Steel - High Strength Bolting
FAHAD FATEH
12/06/2024
Special inspection requirement — Structural Steel - Welding
FAHAD FATEH
12/06/2024
Special inspection requirement — Structural Steel - Details
FAHAD FATEH
12/06/2024
Special inspection requirement — Footing and Foundation
FAHAD FATEH
12/05/2024
Permit issued — Foundation
B00698785-S6-FO
12/05/2024
Permit issued — General Construction
B00698785-I1-GC
11/26/2024
Violation issued (HPD, closed)
I
11/25/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
FOUNDATION & EARTWORK SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION # B00698785-I1.
B00698785-P6
09/23/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Latest 60 of 213 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
G S INSTALLATIONS 1115807/08/2026
OWNER'S REP1007/08/2026
147 PENN ST LLC303/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/23/2021$1.4M—— → —$480/sf building
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC3403/21/2026
G S INSTALLATIONS 111203/21/2026
THE GREEN STUDIO103/21/2026
MILLENNIUM DESIGNS103/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CREATIVE BUILDERS& DEVEL*General Contractor2307/08/2026
GWT ENTERPRISES INCGeneral Contractor603/21/2026
MANHATTAN D ENTERPRISESGeneral Contractor407/08/2026
SOLAS ELECTRICAL CORPElectrical103/22/2026
TARGET PIPING NY LLCFire Protection107/08/2026
HIGH STANDARD ELECTRICElectrical103/22/2026
B&B MECH PLBG & HTG LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HRF SERVICES CORP56161612/06/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offCREATIVE BUILDERS& DEVEL*12/20/2024
DOB NOWFoundationSigned-offCREATIVE BUILDERS& DEVEL*12/10/2024
DOB NOWStructuralSigned-offCREATIVE BUILDERS& DEVEL*12/10/2024
DOB NOWSupport of ExcavationSigned-offCREATIVE BUILDERS& DEVEL*12/10/2024
DOB NOWFoundationSigned-offCREATIVE BUILDERS& DEVEL*12/05/2024
DOB NOWGeneral ConstructionPermit IssuedCREATIVE BUILDERS& DEVEL*12/05/2024
DOB NOWGeneral ConstructionSigned-offCREATIVE BUILDERS& DEVEL*05/01/2024
DOB NOWSprinklersSigned-offTARGET PIPING NY LLC04/01/2024
DOB NOWSprinklersSigned-offTARGET PIPING NY LLC04/01/2024
DOB NOWSidewalk ShedSigned-offGWT ENTERPRISES INC01/05/2024
DOB NOWSidewalk ShedSigned-offGWT ENTERPRISES INC01/05/2024
DOB NOWSupported ScaffoldSigned-offMANHATTAN D ENTERPRISES12/08/2023
DOB NOWSidewalk ShedSigned-offMANHATTAN D ENTERPRISES12/08/2023
DOB NOWConstruction FenceSigned-offCREATIVE BUILDERS& DEVEL*11/14/2023
DOB NOWGeneral ConstructionSigned-offCREATIVE BUILDERS& DEVEL*08/30/2023
DOB NOWConstruction FenceSigned-offCREATIVE BUILDERS& DEVEL*09/16/2022
DOB NOWGeneral ConstructionSigned-offCREATIVE BUILDERS& DEVEL*09/12/2022
▾Field Inspections (DOB CAP) — 8
DateTypeResultReport
02/05/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/04/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/30/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/14/2025Pass-Final CND-Occupancy InspectionPassView ↗
01/08/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
12/20/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/22/2024Pass-Final PL - Up to 9 Requested FloorsPassView ↗
05/06/2024Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 122
DateRequirementInspectorRole
12/18/2024Fire-Resistant Penetrations and JointsFAHAD FATEHspecial
12/18/2024Shutoff dampersFAHAD FATEHenergy_progress
12/18/2024HVAC-R and service water heating equipmentFAHAD FATEHenergy_progress
12/18/2024HVAC-R and service water heating system controlsFAHAD FATEHenergy_progress
12/18/2024Maintenance informationFAHAD FATEHenergy_progress
12/18/2024HVAC-R and service water piping design and insulationFAHAD FATEHenergy_progress
12/18/2024Duct leakage testing, insulation and designFAHAD FATEHenergy_progress
12/18/2024Electrical motors and elevatorsFAHAD FATEHenergy_progress
12/18/2024FinalFAHAD FATEHprogress
12/18/2024Energy Code Compliance InspectionsFAHAD FATEHprogress
12/18/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
12/18/2024Mechanical SystemsFAHAD FATEHspecial
12/18/2024Heating SystemsFAHAD FATEHspecial
12/09/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
12/09/2024Structural Steel - High Strength BoltingFAHAD FATEHspecial
12/09/2024Structural Steel - DetailsFAHAD FATEHspecial
12/09/2024Structural Cold-Formed SteelFAHAD FATEHspecial
12/09/2024FinalFAHAD FATEHprogress
12/09/2024Post-installed AnchorsFAHAD FATEHspecial
12/09/2024FinalFAHAD FATEHprogress
12/09/2024Footing and FoundationFAHAD FATEHprogress
12/09/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
12/09/2024Subsurface Investigations (Borings/Test Pits)FAHAD FATEHspecial
12/09/2024Structural Steel - WeldingFAHAD FATEHspecial
12/06/2024Structural Stability – Alterations of existing buildingsFAHAD FATEHspecial
Latest 25 of 122.
▾Documents — 115 on file (BIS + DOB NOW)
▸Plans & Drawings17
▸DOB NOWPlans/Sketch17
08/26/2026B00971519-I1Request digital key ↗
08/23/2026B00698785-S6Request digital key ↗
08/23/2026B00698785-S4Request digital key ↗
Showing 3 of 17 on file for this type
▸Zoning, Tax Lot & Property Records11
▸DOB NOWZD1: DOB Zoning Diagram5
08/13/2026B00698785-I1Open ↗
08/13/2026B00698785-P3Open ↗
08/13/2026B00698785-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWZoning Exhibit form (1-5)5
08/13/2026B00698785-P3Open ↗
08/13/2026B00698785-P6Open ↗
08/13/2026B00698785-P2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026B00698785-I1Open ↗
▸Seals & Professional Certifications42
▸DOB NOWDPL-1: Design Professional Seal & Signature18
08/23/2026B00698785-P2Open ↗
08/23/2026B00698785-A1Open ↗
08/23/2026B00698785-P5Open ↗
Showing 3 of 18 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature13
09/19/2026B00698785-S1Open ↗
09/19/2026B00698785-S1Open ↗
09/01/2026B00698785-S2Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWProgress Inspector Seal & Signature11
09/19/2026B00698785-S1Open ↗
09/19/2026B00698785-S1Open ↗
09/01/2026B00698785-S2Open ↗
Showing 3 of 11 on file for this type
▸Trade Schedules & Equipment5
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)5
08/13/2026B00698785-I1Open ↗
08/13/2026B00698785-P3Open ↗
08/13/2026B00698785-P6Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Trees Site Plan1
08/13/2026B00698785-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026B00698785-I1Open ↗
▸DOB NOWStreet Tree Sign Off1
08/13/2026B00698785-I1Open ↗
▸Environmental & Asbestos13
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/23/2026B00698785-S6Open ↗
08/23/2026B00698785-S3Open ↗
08/23/2026B00698785-A1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/15/2026B00698785-S2Open ↗
▸Energy Compliance2
▸DOB NOWEN2: As Built Energy Analysis2
08/13/2026B00698785-I1Open ↗
08/13/2026B00762756-I1Open ↗
▸Inspections & Test Reports3
▸DOB NOWSOIL REPORT2
08/13/2026B00698785-P7Open ↗
08/13/2026B00698785-S4Open ↗
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026B00698785-S4Open ↗
▸Other Documents19
▸DOB NOWSite Survey: Initial5
08/13/2026B00698785-P2Open ↗
08/13/2026B00698785-P6Open ↗
08/13/2026B00698785-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone5
08/13/2026B00698785-I1Open ↗
08/13/2026B00698785-P6Open ↗
08/13/2026B00698785-P3Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProperty Ownership Certification5
08/23/2026B00698785-P6Open ↗
08/23/2026B00698785-P1Open ↗
08/23/2026B00698785-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWAdjoining Owners Notification2
08/13/2026B00698785-S4Open ↗
08/13/2026B00698785-S5Open ↗
▸DOB NOWPARTIAL DEMO: 10-DAY Notice1
08/13/2026B00698785-S3Open ↗
▸DOB NOWFinal Survey1
08/13/2026B00698785-I1Open ↗