← Back
Walk-up apt, over six families with stores
El Caribe Apartments
147 RIVINGTON STREET · BIN 1004170
💬 Discuss this project
1910Year Built
5Stories
C7Building Class
R7AZoning
5,441 sfGross Floor Area
8Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: EL CARIBE HOUSING DEVELOPMENT FUND COMPA NY, INC. · 979 sf lot · 5.56 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 12p · 1 filing · 9 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
EL CARIBE HOUSING DEVELOPMENT FUND COMPA NY, INC.103/22/2026
HPD303/21/2026
EL CARIBE LIMITED PARTNERSHIP303/21/2026
EL CARIBE HOUSING DEVELOPMENT FUND COMPANY INC103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FOCAL POINT ARCHITECTS & ASS.101/07/2024
ALBERTO ROMAN108/11/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
FOCAL POINT DESIGN & CONST. INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DONE RIGHT KITCHEN EXHAUSGeneral Contractor303/21/2026
TJAR GROUP CORPGeneral Contractor303/21/2026
DAIDONE, SElectrical103/21/2026
WHITE HALL RESTORATIONElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
HSU & ASSOCIATES8025101/07/2024
AR-TECH ENGINEERING, P.C.6659108/11/2020
Building Lifecycle
All (19)Filed (2)Permit Issued (2)Signed Off (1)Violation (5)Inspection (2)Objection (2)Special Inspection (5)
06/21/2024
Signed off — Alteration
INSTALLING ADA RAMP AT STORE ENTRANCE. NO CHANGE IN EGRESS, OCCUPANCY AND USE.
M00954413-I1
06/14/2024
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/25/2024
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/07/2024
Permit issued — General Construction
M00954413-I1-GC
01/10/2024
Objection raised — Fire_Protection
01/10/2024
Objection resolved — Addressed
01/07/2024
Filed — Alteration
INSTALLING ADA RAMP AT STORE ENTRANCE. NO CHANGE IN EGRESS, OCCUPANCY AND USE.
M00954413-I1
08/12/2020
Permit issued — Mechanical Systems
M00381070-I1-MS
08/11/2020
Filed — Alteration
FILING TO INSTALL NEW KITCHEN EXHAUST SYSTEM FOR EXISTING DELI . NO CHANGE IN USE , ERGRESS OR OCCUPANCY.
M00381070-I1
08/11/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALBERTO ROMAN
08/11/2020
Special inspection requirement — Energy Code Compliance Inspections
ALBERTO ROMAN
08/11/2020
Special inspection requirement — Duct leakage testing
ALBERTO ROMAN
08/05/2020
Special inspection requirement — Mechanical Systems
ALBERTO ROMAN
08/05/2020
Special inspection requirement — Final
ALBERTO ROMAN
04/24/2015
Violation issued (HPD, closed)
C
04/24/2015
Violation issued (HPD, closed)
B
04/24/2015
Violation issued (HPD, closed)
C
03/18/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/25/1990
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offTJAR GROUP CORP03/07/2024
DOB NOWMechanical SystemsPermit IssuedDONE RIGHT KITCHEN EXHAUS08/12/2020
BISEQISSUEDTRIPLE 8 CONSTRUCTION INC03/05/2010
BISOTISSUEDTRIPLE 8 CONSTRUCTION INC03/05/2010
BIS—ISSUEDPROCIDA CONSTRUCTION CORP.12/18/1998
BISPLISSUEDIHOPE PLG & HTG CO INC01/30/1998
BISBLISSUEDIHOPE PLG & HTG CO INC01/30/1998
BISEQISSUEDROCKLEDGE SCAFFOLD CORP04/10/1997
BIS—ISSUEDPROCIDA CONST. CORP03/13/1997
BISEQISSUEDROCKLEDGE SCAFFOLD CORP02/12/1997
BISPLISSUEDIHOPE PLUMBING & HEATING CO01/27/1997
BIS—ISSUEDPROCIDA CONST. CORP12/11/1996
1 project · most recent 08/11/2020
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/11/2020Permit IssuedDONE RIGHT KITCHEN EXHAUSVentilation Systems
Ventilation
Pen Vent FX 18B 2,800 CFM · Exhaust Fan ×1
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/14/2024Pass-Final General Construction Non-Directive 14PassView ↗
04/25/2024Fail-Final General Construction Non-Directive 14FailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
08/11/2020Fire-Resistant Penetrations and JointsALBERTO ROMANspecial
08/11/2020Energy Code Compliance InspectionsALBERTO ROMANprogress
08/11/2020Duct leakage testingALBERTO ROMANenergy_progress
08/05/2020Mechanical SystemsALBERTO ROMANspecial
08/05/2020FinalALBERTO ROMANprogress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch1
08/15/2026M00954413-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
09/04/2026M00381070-I1Request digital key ↗
▸Applications & Permits3
▸BISWORK PERMIT APPLICATION2
03/05/2010120251100Open ↗
03/05/2010120251100Open ↗
▸BISPLAN / WORK APPROVAL APPLICATION1
01/21/2010120251100Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature3
08/22/2026M00381070-I1Open ↗
08/22/2026M00381070-I1Open ↗
08/22/2026M00381070-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/22/2026M00381070-I1Open ↗
08/22/2026M00381070-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026M00954413-I1Open ↗
08/13/2026M00381070-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
01/21/2010120251100Open ↗
▸Safety & Tenant Protection1
▸DOB NOWTenant Protection Plan1
08/13/2026M00381070-I1Open ↗
▸Environmental & Asbestos3
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
01/21/2010120251100Open ↗
▸BISASBESTOS-CERTIFICATION (DEP ACP5)1
01/21/2010120251100Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026M00381070-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸BISADMINISTRATIVE OBJECTIONS1
01/21/2010120251100Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
01/21/2010120251100Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
01/21/2010120251100Open ↗