← Back
Two stories - detached, small or mid-size
147 RUGBY ROAD
BROOKLYN · BIN 3117552
💬 Discuss this project
1910Year Built
2.5Stories
A1Building Class
R1-2Zoning
4,155 sfGross Floor Area
1Units
Rent Stabilized0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: RUGBY GREEN HOUSE LLC · 6,500 sf lot · 0.64 FAR built · Flood zone X
Locations of Work
ArchitectureStructural
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 2 filings · 8 docs
Floor 1Under Construction6p · 2 filings · 8 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/26/2024$3.2M—147 RUGBY ROAD LLC → RUGBY GREEN HOUSE LLC$782/sf building
09/25/2013$2.2M—— → —$529/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
IVAN DESIGN ENG. ANALYSIS, PLLC112/21/2025
ILYA KOROLEV112/18/2025
WELLS ENGINEERING, PLLC112/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
LLOYD NOEL BUILDING CONSULTANT303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
H BUILDING MANAGEMENT INCGeneral Contractor204/09/2026
INDY ELECTRIC CORP.Electrical103/22/2026
Building Lifecycle
All (14)Filed (3)Permit Issued (2)Violation (5)Objection (2)Special Inspection (2)
04/07/2026
Permit issued — Structural
B01307183-I1-ST
04/02/2026
Permit issued — General Construction
B01307180-I1-GC
01/14/2026
Objection resolved — Addressed
01/12/2026
Objection raised — Admin
12/21/2025
Filed — Alteration
REPLACE DETACHED GARAGE ROOF FRAMING. NO CHANGE OF USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
B01307183-I1
12/18/2025
Filed — Alteration
B01307180-I1
12/18/2025
Filed — Alteration
Installation of A new single split HVAC system for an existing garage of a 1 family house. No change of use, egress or occupancy under this application.
B01307189-I1
10/22/2025
Special inspection requirement — Mechanical Systems
10/22/2025
Special inspection requirement — Final
07/02/2024
Violation issued (HPD, closed)
I
06/28/2024
Violation issued (HPD, closed)
B
06/28/2024
Violation issued (HPD, closed)
B
06/28/2024
Violation issued (HPD, closed)
C
06/27/2024
Violation issued (HPD, closed)
B
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralPermit IssuedH BUILDING MANAGEMENT INC04/07/2026
DOB NOWGeneral ConstructionPermit IssuedH BUILDING MANAGEMENT INC04/02/2026
1 job · most recent 12/18/2025
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
12/18/2025——Heating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MUZ-FX18NLHZ 19,800 BTU · Condensing Unit ×1
2 jobs · most recent 02/17/2025
FiledStatusContractorScope
02/17/2025CompleteINDY ELECTRIC CORP.1 meters, 1 new_meters
09/04/2024CompleteSWITCH ELECT OF THE FIVE1 meters, 1 new_meters
1 job · most recent 12/21/2025
Wood
FiledStatusContractorScope
12/21/2025Permit IssuedH BUILDING MANAGEMENT INCWood
▾Special Inspection Requirements (DOB NOW) — 2
DateRequirementInspectorRole
10/22/2025Mechanical Systems—special
10/22/2025Final—progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/19/2026B01307189-I1Request digital key ↗
08/19/2026B01307180-I1Request digital key ↗
08/19/2026B01307183-I1Request digital key ↗
▸Applications & Permits3
▸DOB NOWLPC Approval/Permit3
08/13/2026B01307189-I1Open ↗
08/13/2026B01307180-I1Open ↗
08/13/2026B01307183-I1Open ↗
▸Seals & Professional Certifications3
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/19/2026B01307189-I1Open ↗
08/19/2026B01307180-I1Open ↗
08/13/2026B01307183-I1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/19/2026B01307189-I1Open ↗
08/19/2026B01307180-I1Open ↗
08/13/2026B01307183-I1Open ↗