← Back
One family attached or semi-detached
148-40 61 ROAD
QUEENS · BIN 4140987
💬 Discuss this project
1950Year Built
2Stories
A5Building Class
R4Zoning
1,260 sfGross Floor Area
1Units
One family attached or semi-detached · 1,800 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Permit Issued — active, not yet Signed-off
Floor 2Under Construction8p · 4 filings · 20 docs
Floor 1Under Construction7p · 2 filings · 6 docs
CellarUnder Construction7p · 2 filings · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
01/28/2026$920K—Private party → Private party$730/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ZHENG & ASSOCIATES LLC204/28/2026
ADEL SAGEER ARCHITECT, PLLC203/30/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ZAQ CONSTRUCTION INCGeneral Contractor104/09/2026
WATSON'S PLBG, HTG, & BDGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ZHENG & ASSOCIATES LLC7330404/28/2026
Building Lifecycle
All (20)Filed (4)Permit Issued (2)Inspection (5)Objection (4)Special Inspection (5)
07/23/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
06/24/2026
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
06/24/2026
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
06/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/22/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/03/2026
Objection resolved — Addressed
05/26/2026
Objection raised — Other
05/08/2026
Objection raised — Other
05/08/2026
Objection raised — Admin
04/28/2026
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR TWO FAMILY DWELLING UNIT. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01391340-I1
04/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jinfar Liu
04/27/2026
Special inspection requirement — Energy Code Compliance Inspections
Jinfar Liu
04/27/2026
Special inspection requirement — HVAC-R and service water heating equipment
Jinfar Liu
04/27/2026
Special inspection requirement — HVAC-R and service water heating system controls
Jinfar Liu
04/27/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Jinfar Liu
04/23/2026
Filed — Alteration CO
CONVERT EXISTING ONE TO TWO FAMILY DWELLING UNIT. NO EXTENSION INVOLVED. OBTAIN NEW C OF O.
Q01390518-I1
04/10/2026
Permit issued — Plumbing
Q01373686-I1-PL
04/03/2026
Permit issued — General Construction
Q01373677-I1-GC
03/30/2026
Filed — Alteration
INSTALL PLUMBING FIXTURES FOR 1 FAMILY DWELLING UNIT OF CELLAR, 1ST & 2ND FLOOR. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01373686-I1
03/30/2026
Filed — Alteration
INTERIOR RENOVATION FOR ONE FAMILY DWELLING UNIT OF CELLAR, 1ST & 2ND FLOOR. NO CHANGE IN USE OF EGRESS & OCCUPANCY.
Q01373677-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedWATSON'S PLBG, HTG, & BDG04/10/2026
DOB NOWGeneral ConstructionPermit IssuedZAQ CONSTRUCTION INC04/03/2026
2 projects · most recent 04/28/2026
Gas Water/Sanitary Storm
FiledStatusContractorScope
04/28/2026——Gas, Water/Sanitary
03/30/2026Permit IssuedWATSON'S PLBG, HTG, & BDGGas, Storm, Water/Sanitary
1 project · most recent 08/11/2026
General Wiring
FiledStatusContractorScope
08/11/2026Permit IssuedKJK ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
07/23/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
06/24/2026Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/24/2026Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
06/24/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
06/22/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/27/2026Fire-Resistant Penetrations and JointsJinfar Liuspecial
04/27/2026Energy Code Compliance InspectionsJinfar Liuprogress
04/27/2026HVAC-R and service water heating equipmentJinfar Liuenergy_progress
04/27/2026HVAC-R and service water heating system controlsJinfar Liuenergy_progress
04/27/2026HVAC-R and service water piping design and insulationJinfar Liuenergy_progress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/29/2026Q01390518-I1Request digital key ↗
08/17/2026Q01373677-I1Request digital key ↗
08/17/2026Q01373686-I1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/17/2026Q01390518-I1Open ↗
08/14/2026Q01391340-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026Q01373677-I1Open ↗
08/17/2026Q01373686-I1Open ↗
08/17/2026Q01390518-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature2
08/25/2026Q01391340-I1Open ↗
08/25/2026Q01391340-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/25/2026Q01391340-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/17/2026Q01390518-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026Q01373677-I1Open ↗
08/17/2026Q01373686-I1Open ↗
08/17/2026Q01390518-I1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents1
▸DOB NOWProperty Ownership Certification1
08/17/2026Q01390518-I1Open ↗