← Back
Two family brick
148 BERKELEY PLACE
BROOKLYN · Park Slope · BIN 3019864
💬 Discuss this project
1875Year Built
3Stories
B1Building Class
R6BZoning
2,880 sfGross Floor Area
2Units
Two family brick · 1,583 sf lot · 1.82 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalOther
Roof2p · 2 filings · 20 docs
Floor 33p · 1 filing · 20 docs
Floor 25p · 2 filings · 20 docs
Floor 15p · 2 filings · 20 docs
Cellar7p · 2 filings · 20 docs
Basement4p · 2 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/26/2021$3.2M—— → —$1,128/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FORMAT ARCHITECTURE OFFICE, PLLC312/08/2023
VASILIOS ARTEMIOU PE206/10/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EC BUILDING CONSULTANTS1003/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ORCHESTER MANAGEMENT COM*General Contractor507/08/2026
P.L. ELEC'L CONTR'G CORPElectrical103/22/2026
BT'S PLUMBING AND HEATINGPlumbing107/08/2026
PLUMB-IT MECHANICAL INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACE STRUCTURAL ENGINEERIN496512/08/2023
Building Lifecycle
All (45)Filed (5)Permit Issued (5)Signed Off (2)Inspection (7)Objection (4)Special Inspection (22)
01/19/2024
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/08/2023
Filed — Alteration CO
B00687649-P2
11/21/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY UGBEBOR
11/21/2023
Special inspection requirement — Structural Steel - Details
ANTHONY UGBEBOR
11/21/2023
Special inspection requirement — Structural Steel - High Strength Bolting
ANTHONY UGBEBOR
11/21/2023
Special inspection requirement — Structural Steel - Welding
ANTHONY UGBEBOR
11/21/2023
Special inspection requirement — Energy Code Compliance Inspections
Andrew McGee
11/21/2023
Special inspection requirement — Final
Andrew McGee
11/21/2023
Special inspection requirement — Fire-Resistance Rated Construction
Andrew McGee
11/21/2023
Special inspection requirement — Exterior lighting power
Andrew McGee
11/21/2023
Special inspection requirement — Lighting controls
Andrew McGee
11/21/2023
Special inspection requirement — Interior lighting power
Andrew McGee
10/11/2023
Signed off — Alteration
Installation of plumbing fixtures with related piping as shown on drawings and Schedule B.
B00753537-I1
09/27/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/21/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
07/18/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/12/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
06/02/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
05/25/2023
Filed — Alteration CO
B00687649-P1
05/16/2023
Signed off — Alteration
Installation of new split system units and exhaust fans as shown on drawings.
B00753591-I1
11/29/2022
Permit issued — Plumbing
B00753537-I1-PL
07/27/2022
Permit issued — Plumbing
B00753537-I1-PL
07/12/2022
Permit issued — Structural
B00687649-I1-GC
07/12/2022
Permit issued — Mechanical Systems
B00753591-I1-MS
07/12/2022
Permit issued — Structural
B00687649-I1-ST
06/24/2022
Objection resolved — Addressed
06/24/2022
Objection resolved — Addressed
06/19/2022
Objection raised — Fire_Protection
06/19/2022
Objection raised — Energy
06/10/2022
Filed — Alteration
Installation of plumbing fixtures with related piping as shown on drawings and Schedule B.
B00753537-I1
06/10/2022
Filed — Alteration
Installation of new split system units and exhaust fans as shown on drawings.
B00753591-I1
06/08/2022
Filed — Alteration CO
B00687649-I1
06/08/2022
Special inspection requirement — HVAC-R and service water heating equipment
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Shutoff dampers
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Mechanical Systems
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Heating Systems
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Final
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Duct leakage testing, insulation and design
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — HVAC-R and service water heating system controls
ANTHONY UGBEBOR
06/08/2022
Special inspection requirement — Maintenance information
ANTHONY UGBEBOR
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offJVR PLBG AND HEATING INC11/29/2022
DOB NOWPlumbingSigned-offBT'S PLUMBING AND HEATING07/27/2022
DOB NOWStructuralPermit IssuedORCHESTER MANAGEMENT COM*07/12/2022
DOB NOWMechanical SystemsSigned-offORCHESTER MANAGEMENT COM*07/12/2022
DOB NOWStructuralSigned-offORCHESTER MANAGEMENT COM*07/12/2022
BIS—ISSUEDBUCK MOORHEAD ARCH01/29/1997
2 projects · most recent 08/25/2023
General Wiring
FiledStatusContractorScope
08/25/2023CompleteP.L. ELEC'L CONTR'G CORP3 meters, 1 new_meters
08/04/2022CompleteP.L. ELEC'L CONTR'G CORPGeneral Wiring
▾Field Inspections (DOB CAP) — 7
DateTypeResultReport
01/19/2024Pass-Final CND-Occupancy InspectionPassView ↗
09/27/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/21/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
07/18/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
06/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/12/2023Pass-Final CND-Occupancy InspectionPassView ↗
06/02/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
11/21/2023Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
11/21/2023Structural Steel - DetailsANTHONY UGBEBORspecial
11/21/2023Structural Steel - High Strength BoltingANTHONY UGBEBORspecial
11/21/2023Structural Steel - WeldingANTHONY UGBEBORspecial
11/21/2023Energy Code Compliance InspectionsAndrew McGeeprogress
11/21/2023FinalAndrew McGeeprogress
11/21/2023Fire-Resistance Rated ConstructionAndrew McGeeprogress
11/21/2023Exterior lighting powerAndrew McGeeenergy_progress
11/21/2023Lighting controlsAndrew McGeeenergy_progress
11/21/2023Interior lighting powerAndrew McGeeenergy_progress
06/08/2022HVAC-R and service water heating equipmentANTHONY UGBEBORenergy_progress
06/08/2022Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
06/08/2022Shutoff dampersANTHONY UGBEBORenergy_progress
06/08/2022Mechanical SystemsANTHONY UGBEBORspecial
06/08/2022Fire-Resistant Penetrations and JointsANTHONY UGBEBORspecial
06/08/2022Heating SystemsANTHONY UGBEBORspecial
06/08/2022FinalANTHONY UGBEBORprogress
06/08/2022Energy Code Compliance InspectionsANTHONY UGBEBORprogress
06/08/2022HVAC-R and service water piping design and insulationANTHONY UGBEBORenergy_progress
06/08/2022Duct leakage testing, insulation and designANTHONY UGBEBORenergy_progress
06/08/2022HVAC-R and service water heating system controlsANTHONY UGBEBORenergy_progress
06/08/2022Maintenance informationANTHONY UGBEBORenergy_progress
▾Documents — 49 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/29/2026B00753537-I1Request digital key ↗
08/26/2026B00687649-I1Request digital key ↗
08/26/2026B00687649-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Applications & Permits5
▸DOB NOWLPC Approval/Permit5
08/29/2026B00753537-I1Open ↗
08/15/2026B00753591-I1Open ↗
08/13/2026B00687649-P2Open ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications27
▸DOB NOWProgress Inspector Seal & Signature14
09/02/2026B00753591-I1Open ↗
09/02/2026B00753591-I1Open ↗
09/02/2026B00753591-I1Open ↗
Showing 3 of 14 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/02/2026B00753591-I1Open ↗
09/02/2026B00753591-I1Open ↗
09/02/2026B00753591-I1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/29/2026B00753591-I1Open ↗
08/29/2026B00753537-I1Open ↗
08/26/2026B00687649-P2Open ↗
Showing 3 of 5 on file for this type
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist3
08/26/2026B00687649-P2Open ↗
08/26/2026B00687649-P1Open ↗
08/26/2026B00687649-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/29/2026B00753537-I1Open ↗
08/26/2026B00687649-P2Open ↗
08/26/2026B00687649-P1Open ↗
Showing 3 of 5 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026B00687649-I1Open ↗
▸Other Documents3
▸DOB NOWProperty Ownership Certification3
08/26/2026B00687649-P2Open ↗
08/26/2026B00687649-P1Open ↗
08/26/2026B00687649-I1Open ↗