| Owner | Filings | Most Recent |
|---|---|---|
| SCG CAPITAL | 29 | 04/09/2026 |
| 711 E | 15 | 04/09/2026 |
| Date | Price | Unit | Seller → Buyer | $/sf |
|---|---|---|---|---|
| 08/29/2024 | $1000K | — | WEBER'S PROPERTY LLC → 1486 SZ AS LLC | $391/sf building |
| Firm | Filings | Most Recent |
|---|---|---|
| NIKOLAI KATZ ARCHITECT | 6 | 08/19/2025 |
| STONECREST ENGINEERING LLC | 3 | 05/13/2025 |
| VASILIOS ARTEMIOU PE | 7 | 12/26/2024 |
| Representative | Filings | Most Recent |
|---|---|---|
| EXPRESS FILING INC | 32 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| H BUILDERS NYC LLC | General Contractor | 9 | 04/09/2026 |
| PRIME PIPING & HEATING IN | Fire Protection | 1 | 07/08/2026 |
| PRIME PIPING & HEATING IN | Plumbing | 1 | 07/08/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| SHAHRISH SHUVO ENGINEERIN | 8524 | 2 | 08/19/2025 |
| HRF SERVICES CORP | 5616 | 12 | 08/06/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | Structural | Signed-off | H BUILDERS NYC LLC | 10/27/2025 |
| DOB NOW | Support of Excavation | Signed-off | H BUILDERS NYC LLC | 05/23/2025 |
| DOB NOW | Foundation | Permit Issued | H BUILDERS NYC LLC | 05/08/2025 |
| DOB NOW | Construction Fence | Signed-off | H BUILDERS NYC LLC | 04/22/2025 |
| DOB NOW | General Construction | Permit Issued | H BUILDERS NYC LLC | 01/24/2025 |
| DOB NOW | Mechanical Systems | Signed-off | H BUILDERS NYC LLC | 10/28/2024 |
| DOB NOW | General Construction | Permit Issued | H BUILDERS NYC LLC | 10/01/2024 |
| DOB NOW | Sprinklers | Signed-off | A M B MECHANICAL INC | 09/17/2024 |
| DOB NOW | Plumbing | Signed-off | PRIME PIPING & HEATING IN | 09/17/2024 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 08/19/2025 | Signed-off | H BUILDERS NYC LLC | Heating and Air Conditioning Systems | Heat / Cool Daikin RXF18AXVJU 20,000 BTU · Heat Pump Outdoor ×4 2MXM18AVJU9 18,900 BTU · Heat Pump Outdoor ×3 3MXS24WMVJU 24,000 BTU · Vrf Outdoor ×4 4MXS36RMVJUA 36,000 BTU · Heat Pump Outdoor ×2 RZQ18TBVJUA 20,000 BTU · Heat Pump Outdoor ×4 2MXS18NMVJUA 18,900 BTU · Heat Pump Outdoor ×3 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Signed-off | PRIME PIPING & HEATING IN | Sprinkler System |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Signed-off | PRIME PIPING & HEATING IN | Storm, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 06/02/2026 | Complete | BROOKLYN POWER ELECTRIC C | General Wiring |
| 07/23/2025 | Complete | FRIED ELECTRIC CO. | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Signed-off | H BUILDERS NYC LLC | 3 scope_items |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Signed-off | H BUILDERS NYC LLC | Fence |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 08/19/2025 | Signed-off | H BUILDERS NYC LLC | Earthwork |
| Date | Type | Result | Report |
|---|---|---|---|
| 12/19/2025 | Certified Gas-Gas-Piping-Roughing | Certified | View ↗ |
| 11/03/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/27/2025 | Certified Sprinkler-SP-Fixtures-Finish | Certified | View ↗ |
| 06/24/2025 | Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test | Certified | View ↗ |
| 06/24/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 06/09/2025 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 03/11/2025 | Pass-Final CND-Occupancy Inspection | Pass | View ↗ |
| 11/29/2024 | Certified Storm Drainage-ST-Piping-Underground | Certified | View ↗ |
| 11/29/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Roughing | Certified | View ↗ |
| 11/29/2024 | Certified Water and Sanitary-WS-Sanitary Piping-Underground | Certified | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 08/18/2025 | Structural Cold-Formed Steel | Shahrish Shuvo | special |
| 08/18/2025 | Lowest Floor Elevation | Shahrish Shuvo | progress |
| 08/18/2025 | Fire-Resistance Rated Construction | Shahrish Shuvo | progress |
| 08/18/2025 | Energy Code Compliance Inspections | Shahrish Shuvo | progress |
| 08/18/2025 | Final | Shahrish Shuvo | progress |
| 08/18/2025 | Wall Panels, Curtain Walls, and Veneers | Shahrish Shuvo | special |
| 08/18/2025 | Fire-Resistant Penetrations and Joints | Shahrish Shuvo | special |
| 08/18/2025 | Structural Steel - Details | Shahrish Shuvo | special |
| 08/01/2025 | Interior lighting power | FAHAD FATEH | energy_progress |
| 08/01/2025 | Insulation placement and R values | FAHAD FATEH | energy_progress |
| 08/01/2025 | Maintenance information | FAHAD FATEH | energy_progress |
| 08/01/2025 | Permanent certificate | FAHAD FATEH | energy_progress |
| 08/01/2025 | Fenestration air leakage | FAHAD FATEH | energy_progress |
| 08/01/2025 | Fire-Resistant Penetrations and Joints | FAHAD FATEH | special |
| 08/01/2025 | Structural Stability – Alterations of existing buildings | FAHAD FATEH | special |
| 08/01/2025 | Energy Code Compliance Inspections | FAHAD FATEH | progress |
| 08/01/2025 | Fire-Resistance Rated Construction | FAHAD FATEH | progress |
| 08/01/2025 | Fenestration areas | FAHAD FATEH | energy_progress |
| 08/01/2025 | Metering | FAHAD FATEH | energy_progress |
| 08/01/2025 | Fenestration and door U-factor and product ratings | FAHAD FATEH | energy_progress |
| 08/01/2025 | Air barrier - visual inspection | FAHAD FATEH | energy_progress |
| 05/19/2025 | Concrete - Cast-In-Place | Shahrish Shuvo | special |
| 05/19/2025 | Footing and Foundation | Shahrish Shuvo | progress |
| 05/19/2025 | Subgrade Inspections | Shahrish Shuvo | special |
| 05/19/2025 | Final | Shahrish Shuvo | progress |