← Back
Shopping center, with or without parking
1489 FOREST AVENUE
STATEN ISLAND · BIN 5110055
💬 Discuss this project
1957Year Built
1Stories
K6Building Class
C4-1Zoning
245,118 sfGross Floor Area
24Units
0 Open ViolationsFDNY Report ↗
Shopping center, with or without parking · 586,050 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingLandscapeGeneral
Roof7p · 6 filings · 20 docs
Floor 19p · 3 filings · 20 docs
Mezzanine1p · 1 filing · 7 docs
Cellar8p · 3 filings · 20 docs
1 job · most recent 05/22/2023
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
05/22/2023Signed-offGTL CONSTRUCTION LLCHeating and Air Conditioning Systems
Heat / Cool
Carrier 48HCEG08A2M5A6W1J0 89,000 BTU · Rooftop Unit ×15
48HCEG12A2M5A6W1J0 115,000 BTU · Rooftop Unit ×5
4 jobs · most recent 05/12/2025
General Wiring
FiledStatusContractorScope
05/12/2025CompleteSHELBY ELECTRICAL CORP—
12/23/2024CompleteM & M CONTROL WIRING &General Wiring
02/14/2023CompleteSIGNS CAD CORP—
12/28/2022CompleteDELCO ELECTRICAL CORP.General Wiring
Building Lifecycle
All (105)Filed (22)Permit Issued (18)Signed Off (13)Violation (11)Inspection (11)Special Inspection (30)
03/04/2026
Violation issued (FDNY_NOV, closed)
11/26/2025
Signed off — Alteration
Remove existing ductwork. Install new ducts, diffusers and toilet room exhaust fan.
S01032780-I1
11/26/2025
Signed off — Alteration
Remove non-load bearing partitions and ceilings, install non-load bearing partitions and ceiling, and toilet rooms. Install new Storefront and entrance doors, and entrance vestibule.
S01032696-I1
09/22/2025
Violation issued (FDNY_ORDER, closed)
06/25/2025
Signed off — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON WALL SIGN BAND STRUCTURE FILED UNDER JOB # S01203190 - IN PROPERTY LINES - KIDS PLACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
S01203191-I1
06/25/2025
Signed off — Alteration
S01203190-I1
04/15/2025
Permit issued — General Construction
S01203190-I1-GC
04/15/2025
Permit issued — Sign
S01203191-I1-SG
04/09/2025
Filed — Alteration
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN ON WALL SIGN BAND STRUCTURE FILED UNDER JOB # S01203190 - IN PROPERTY LINES - KIDS PLACE. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
S01203191-I1
04/09/2025
Filed — Alteration
S01203190-I1
04/09/2025
Special inspection requirement — Final
ADITYA DESAI
01/28/2025
Signed off — Alteration
Provide sanitary, domestic, and venting systems for new toilet rooms.
S01032807-I1
01/27/2025
Filed — Alteration
Provide sanitary, domestic, and venting systems for new toilet rooms.
S01032807-P2
12/18/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
12/18/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
12/06/2024
Filed — Alteration
Provide sanitary, domestic, and venting systems for new toilet rooms.
S01032807-P1
12/05/2024
Special inspection requirement — Non Potable Water Systems
Mudar Khantamr
11/25/2024
Permit issued — General Construction
S01099685-I1-GC
11/19/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/24/2024
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/15/2024
Permit issued — Plumbing
S01032807-I1-PL
09/25/2024
Permit issued — Mechanical Systems
S01032780-I1-MS
09/25/2024
Permit issued — General Construction
S01032696-I1-GC
09/16/2024
Filed — Alteration
S01099685-I1
08/21/2024
Special inspection requirement — Final
Jaclyn Peranteau
06/25/2024
Filed — Alteration
Remove existing ductwork. Install new ducts, diffusers and toilet room exhaust fan.
S01032780-I1
06/25/2024
Filed — Alteration
Remove non-load bearing partitions and ceilings, install non-load bearing partitions and ceiling, and toilet rooms. Install new Storefront and entrance doors, and entrance vestibule.
S01032696-I1
06/25/2024
Filed — Alteration
Provide sanitary, domestic, and venting systems for new toilet rooms.
S01032807-I1
05/10/2024
Special inspection requirement — Fenestration air leakage
Mudar Khantamr
05/10/2024
Special inspection requirement — Fenestration areas
Mudar Khantamr
05/10/2024
Special inspection requirement — Vestibules
Mudar Khantamr
05/10/2024
Special inspection requirement — Fenestration and door U-factor and product ratings
Mudar Khantamr
04/09/2024
Special inspection requirement — Final
Mudar Khantamr
04/09/2024
Special inspection requirement — Mechanical Systems
Mudar Khantamr
04/09/2024
Special inspection requirement — Final
Mudar Khantamr
02/01/2024
Violation issued (FDNY_NOV, closed)
08/17/2023
Violation issued (FDNY_NOV, closed)
06/20/2023
Signed off — Alteration
S00719663-I1
06/20/2023
Signed off — Alteration
Remove existing HVAC units, ducts, and diffusers.
S00719664-I1
06/20/2023
Signed off — Alteration
Provide lintels for new openings, provide new bracing at raised facade.
S00719665-I1
06/14/2023
Signed off — Alteration
New wet sprinkler system includes all piping and sprinkler heads.
S00728596-I1
06/07/2023
Signed off — Alteration
FIVE BELOW-- PLUMBING MODIFICATIONS AND INSTALLATIONS FOR RETAIL BUILD-OUT.
S08017129-I1
06/07/2023
Signed off — Alteration
FIVE BELOW-- GENERAL CONSTRUCTION INCLUSIVE OF INTERIOR PARTITIONS INSTALLATION AS PER PLANS FILED. NO CHANGE TO USE, EGRESS, OR OCCUPANCY.
S08017112-I1
05/30/2023
Signed off — Alteration
ERECT NON-ILLUMINATED ACCESSORY D/F BLADE SIGN-B UNDER STOREFRONT CANOPY STRUCTURE, NON-FLASHING, NON-ADVERTISING SIGN, NO CHANGE IN USE, EGRESS, OR OCCUPANCY
S08035915-I1
05/30/2023
Signed off — Alteration
ERECT ILLUMINATED ACCESSORY BUSINESS CHANNEL LETTER WALL SIGN-A, NO CHANGE TO USE, EGRESS OR OCCUPATION
S08035912-I1
05/23/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
ERIC BERLENT
05/23/2023
Special inspection requirement — Exterior lighting power
ERIC BERLENT
05/23/2023
Special inspection requirement — Final
ERIC BERLENT
05/23/2023
Special inspection requirement — Lighting controls
ERIC BERLENT
05/23/2023
Special inspection requirement — Interior lighting power
ERIC BERLENT
05/23/2023
Special inspection requirement — HVAC-R and service water heating equipment
ERIC BERLENT
05/23/2023
Special inspection requirement — Maintenance information
ERIC BERLENT
05/23/2023
Special inspection requirement — HVAC-R and service water heating system controls
ERIC BERLENT
05/23/2023
Special inspection requirement — Mechanical Systems
ERIC BERLENT
05/22/2023
Filed — Alteration
FIVE BELOW-- MECHANICAL INSTALLATIONS AND MODIFICATION FOR RETAIL BUILD-OUT.
S08017125-P1
05/22/2023
Special inspection requirement — HVAC-R and service water heating system controls
ERIC BERLENT
05/22/2023
Special inspection requirement — Mechanical Systems
ERIC BERLENT
05/22/2023
Special inspection requirement — Final
ERIC BERLENT
05/22/2023
Special inspection requirement — Exterior lighting power
ERIC BERLENT
05/22/2023
Special inspection requirement — HVAC-R and service water heating equipment
ERIC BERLENT
Latest 60 of 105 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
HYLAN PLAZA 13396307/08/2026
DEPT RE-CITY OF NY 040103/22/2026
MICHAEL STORES INC.103/22/2026
KIMCO REALTY103/21/2026
FOREST AVE SHOPPING ASSOC303/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.1003/21/2026
ROSENBAUM DESIGN GROUP1003/21/2026
JP EXPEDITE603/21/2026
LOUIS STRIAR403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
4TL CONSTRUCTION LLCGeneral Contractor1107/08/2026
POINT PROPERTY HOLDINGSGeneral Contractor304/09/2026
SIGNS CADScaffold207/08/2026
FULL CAPACITY FIRE CORPFire Protection107/08/2026
LEVITSKY, HElectrical103/21/2026
L.S. SIGN CO., INCGeneral Contractor107/08/2026
IUOE LOCAL 14-14Electrical103/21/2026
TRI BOROUGH SCAFFOLDINGGeneral Contractor107/08/2026
FLOW-RIGHT PLBG & HTG CORPlumbing107/08/2026
MPC PLUMBING & HEATING INCPlumbing107/08/2026
L S SIGNScaffold107/08/2026
GREENE, JOHNElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WHITESTONE ASSOCIATES ENG8144212/06/2024
CATALPA SPECIAL INSPECTIO2004305/22/2023
DOMANI INSPECTION SERVICE843310/24/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offL.S. SIGN CO., INC04/15/2025
DOB NOWSignSigned-offWEINFELD, ELLIOT04/15/2025
DOB NOWGeneral ConstructionPermit IssuedPOINT PROPERTY HOLDINGS11/25/2024
DOB NOWPlumbingSigned-offMPC PLUMBING & HEATING IN10/15/2024
DOB NOWMechanical SystemsSigned-offPOINT PROPERTY HOLDINGS09/25/2024
DOB NOWGeneral ConstructionSigned-offPOINT PROPERTY HOLDINGS09/25/2024
DOB NOWStructuralSigned-off4TL CONSTRUCTION LLC04/19/2023
DOB NOWMechanical SystemsSigned-off4TL CONSTRUCTION LLC04/19/2023
DOB NOWConstruction FencePermit IssuedTRI BOROUGH SCAFFOLDING12/16/2022
DOB NOWSignSigned-offSIGNS CAD CORP12/09/2022
DOB NOWSignSigned-offFRANK ZANFARDINO12/09/2022
DOB NOWMechanical SystemsSigned-off4TL CONSTRUCTION LLC11/25/2022
DOB NOWGeneral ConstructionSigned-off4TL CONSTRUCTION LLC11/25/2022
DOB NOWGeneral ConstructionSigned-off4TL CONSTRUCTION LLC11/23/2022
DOB NOWSprinklersSigned-offFULL CAPACITY FIRE CORP11/21/2022
DOB NOWPlumbingSigned-offFLOW-RIGHT PLBG & HTG COR11/12/2022
DOB NOWGeneral ConstructionSigned-off4TL CONSTRUCTION LLC11/01/2022
DOB NOWGeneral ConstructionSigned-off4TL CONSTRUCTION LLC10/31/2022
BISFPISSUEDFIRE COMMAND CO, INC02/20/2019
BISPLISSUEDPINNACLE PLBG & HTG CORP11/01/2011
BISFPISSUEDPINNACLE PLBG & HTG CORP08/31/2011
BISSPISSUEDPINNACLE PLBG & HTG CORP06/21/2011
BISPLISSUEDTOP DOG PLBG & HTG CORP06/20/2011
BISOTISSUEDGOOD CENTURY CONSTRUC.INC04/22/2011
BISPLISSUEDPINNACLE PLBG & HTG CORP04/18/2008
BISOTISSUEDNEW EMPIRE CONST INC04/10/2008
BISFPISSUEDFIREMASTERS09/28/2007
BISMHISSUEDSCARAN PLBG, INC.12/26/2002
BISPLISSUEDSCARAN PLUMBING INC12/26/2002
BISPLISSUEDNEW YORK STANDARD MECH CORP04/08/1998
BISMHISSUEDARTCRAFT CONSTR. OF BROOKLYN,INC04/08/1998
BISFPISSUEDLUND FIRE PRODUCTS CO. INC04/02/1998
BISPLISSUEDNEW YORK STANDARD MECH CORP03/23/1998
BISOTISSUEDARTCRAFT CONSTR. OF BROOKLYN,INC03/17/1998
BIS—ISSUEDAMERIVAN SIGNCRAFTERS02/28/1997
BIS—ISSUEDAMERIVAN SIGNCRAFTERS02/28/1997
BIS—ISSUEDCONVERSANO ASSOCIATES, INC.12/13/1996
BISPLISSUEDDUO PLUMBING & HTG CORP.12/05/1996
BISSPISSUEDMARINE SERVICES GROUP LLC11/27/1996
BISFPISSUEDLUND FIRE PRODUCTS CO; INC.11/18/1996
+ 11 more permits on file
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
12/18/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
12/18/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/19/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
10/24/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/03/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/01/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/24/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/09/2023Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/06/2023Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/13/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/15/2022Pass-Final PL - UndergroundPassView ↗
▾Special Inspection Requirements (DOB NOW) — 40
DateRequirementInspectorRole
04/09/2025FinalADITYA DESAIprogress
12/05/2024Non Potable Water SystemsMudar Khantamrspecial
08/21/2024FinalJaclyn Peranteauprogress
05/10/2024Fenestration air leakageMudar Khantamrenergy_progress
05/10/2024Fenestration areasMudar Khantamrenergy_progress
05/10/2024VestibulesMudar Khantamrenergy_progress
05/10/2024Fenestration and door U-factor and product ratingsMudar Khantamrenergy_progress
04/09/2024FinalMudar Khantamrprogress
04/09/2024Mechanical SystemsMudar Khantamrspecial
04/09/2024FinalMudar Khantamrprogress
05/23/2023HVAC-R and service water piping design and insulationERIC BERLENTenergy_progress
05/23/2023Exterior lighting powerERIC BERLENTenergy_progress
05/23/2023FinalERIC BERLENTprogress
05/23/2023Lighting controlsERIC BERLENTenergy_progress
05/23/2023Interior lighting powerERIC BERLENTenergy_progress
05/23/2023HVAC-R and service water heating equipmentERIC BERLENTenergy_progress
05/23/2023Maintenance informationERIC BERLENTenergy_progress
05/23/2023HVAC-R and service water heating system controlsERIC BERLENTenergy_progress
05/23/2023Mechanical SystemsERIC BERLENTspecial
05/22/2023HVAC-R and service water heating system controlsERIC BERLENTenergy_progress
05/22/2023Mechanical SystemsERIC BERLENTspecial
05/22/2023FinalERIC BERLENTprogress
05/22/2023Exterior lighting powerERIC BERLENTenergy_progress
05/22/2023HVAC-R and service water heating equipmentERIC BERLENTenergy_progress
05/22/2023Interior lighting powerERIC BERLENTenergy_progress
Latest 25 of 40.
▾Documents — 218 on file (BIS + DOB NOW)
▸Plans & Drawings22
▸DOB NOWPlans/Sketch22
08/23/2026S00719663-I1Request digital key ↗
08/23/2026S00719666-I1Request digital key ↗
08/23/2026S00728596-I1Request digital key ↗
Showing 3 of 22 on file for this type
▸Applications & Permits25
▸BISPLAN / WORK APPROVAL APPLICATION13
02/17/2019540161625Open ↗
08/29/2013520149508Open ↗
11/01/2011520064821Open ↗
Showing 3 of 13 on file for this type
▸BISWORK PERMIT APPLICATION12
02/17/2019540161625Open ↗
11/02/2011520064821Open ↗
09/01/2011520075515Open ↗
Showing 3 of 12 on file for this type
▸Seals & Professional Certifications64
▸DOB NOWDPL-1: Design Professional Seal & Signature22
08/23/2026S00719663-I1Open ↗
08/23/2026S00719666-I1Open ↗
08/23/2026S00728596-I1Open ↗
Showing 3 of 22 on file for this type
▸DOB NOWProgress Inspector Seal & Signature15
09/23/2026S00719664-I1Open ↗
09/02/2026S01032696-I1Open ↗
09/02/2026S01032696-I1Open ↗
Showing 3 of 15 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION9
06/05/2012520069675Open ↗
02/10/2012520075515Open ↗
02/10/2012520064821Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/23/2026S00719664-I1Open ↗
09/01/2026S00728596-I1Open ↗
08/28/2026S00719665-I1Open ↗
Showing 3 of 8 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST3
06/21/2011520069675Open ↗
04/25/2011520064821Open ↗
04/04/2008510033517Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM3
06/21/2011520069675Open ↗
04/25/2011520064821Open ↗
04/04/2008510033517Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
02/17/2019540161625Open ↗
▸BISPC FULL REPORT1
09/07/2007510015127Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
02/17/2019540161625Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
02/17/2019540161625Open ↗
▸Trade Schedules & Equipment16
▸BISSCHEDULE B - PLUMBING8
11/01/2011520064821Open ↗
09/28/2011520069675Open ↗
08/25/2011520064821Open ↗
Showing 3 of 8 on file for this type
▸BISSELF-CERT PLUMBING NOTICE5
11/30/2011520064821Open ↗
11/03/2011520064821Open ↗
10/14/2011520069675Open ↗
Showing 3 of 5 on file for this type
▸BISSPRINKLER INSP REPORT : FP-852
11/17/2011520069675Open ↗
11/04/2011520069675Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA1
11/02/2011520064821Open ↗
▸Safety & Tenant Protection2
▸BISStreet Trees- Receipt of Street Trees Site Plan1
08/29/2013520149508Open ↗
▸BISSTREET TREE CHECKLIST1
06/21/2011520069675Open ↗
▸Environmental & Asbestos49
▸DOB NOWDEP ACP-5: Asbestos Assessment Report19
08/23/2026S00719663-I1Open ↗
08/23/2026S00719666-I1Open ↗
08/23/2026S00728596-I1Open ↗
Showing 3 of 19 on file for this type
▸DOB NOWOER: Notice to Proceed13
08/13/2026S01032807-I1Open ↗
08/13/2026S01099685-I1Open ↗
08/13/2026S08017125-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWOER: Notice of Satisfaction11
08/13/2026S08017112-I1Open ↗
08/13/2026S01099685-I1Open ↗
08/13/2026S01032696-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'4
08/18/2011520075515Open ↗
07/22/2011520072233Open ↗
04/25/2011520064821Open ↗
Showing 3 of 4 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
02/17/2019540161625Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
09/07/2007510015127Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
06/21/2011520069675Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
02/17/2019540161625Open ↗
▸Approvals, Objections & Sign-offs14
▸BISADMINISTRATIVE OBJECTIONS7
08/29/2013520149508Open ↗
08/18/2011520075515Open ↗
07/22/2011520072233Open ↗
Showing 3 of 7 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
06/08/2012520069675Open ↗
06/05/2012520069675Open ↗
02/10/2012520075515Open ↗
Showing 3 of 4 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION3
02/17/2019540161625Open ↗
02/10/2012520075515Open ↗
01/20/2012520069675Open ↗
▸Cost, Insurance & Ownership12
▸BISCOST AFFIDAVIT12
02/17/2019540161625Open ↗
06/08/2012520069675Open ↗
02/10/2012520075515Open ↗
Showing 3 of 12 on file for this type
▸Filing & Intake Forms11
▸BISEFILING COVER SHEET5
08/29/2013520149508Open ↗
08/18/2011520075515Open ↗
06/21/2011520069675Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION4
08/29/2013520149508Open ↗
08/25/2011520064821Open ↗
08/23/2011520069675Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET1
02/17/2019540161625Open ↗
▸DOB NOWAI1 Form (from plan PDF)1
08/16/2026S08017129-P1Open ↗
▸Other Documents1
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
11/02/2011520064821Open ↗