← Back
Two family frame
149-35 116 STREET
QUEENS · BIN 4256847
💬 Discuss this project
1945Year Built
2Stories
B2Building Class
R3XZoning
1,680 sfGross Floor Area
2Units
4 Open Violations 2 unresolved · 2 paperwork only ▸FDNY Report ↗
Two family frame · Owner of record: AHUJA INC. · 4,000 sf lot · 0.42 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingCivil
Roof1p · 1 filing · 20 docs
Floor 216p · 2 filings · 20 docs
Floor 115p · 1 filing · 20 docs
Cellar24p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AHUJA3009/13/2026
NOVELTY CONSTRUCTION203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/25/2025$950K—Private party → AHUJA INC.$565/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NASIR J, KHANZADA LLC1008/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ARCHITECTUAL CONCEPT803/21/2026
NASIR J. KHANZADA LLC803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NOVELTY CONSTRUCTION CORPGeneral Contractor904/09/2026
INFINITI ESC PLUMBING CORPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
NASIR J. KHANZADA LLC1527208/04/2026
ARCHITECTURAL CONCEPT3642111/17/2025
Building Lifecycle
All (111)Filed (10)Permit Issued (10)Violation (4)Inspection (9)Objection (48)Special Inspection (30)
08/21/2026
Objection resolved — Resolved
08/17/2026
Objection raised — Other
08/04/2026
Filed — Alteration
Alt-2 filed for interior renovation with horizontal extension of an existing two-family house.
Q01173964-P5
07/30/2026
Special inspection requirement — Fenestration air leakage
Nasir Khanzada
07/30/2026
Special inspection requirement — HVAC-R and service water heating equipment
Nasir Khanzada
07/30/2026
Special inspection requirement — Electric vehicle service equipment requirements
Nasir Khanzada
07/30/2026
Special inspection requirement — Interior lighting power
Nasir Khanzada
07/30/2026
Special inspection requirement — Fenestration areas
Nasir Khanzada
07/30/2026
Special inspection requirement — Air barrier - visual inspection
Nasir Khanzada
07/30/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nasir Khanzada
07/30/2026
Special inspection requirement — Mechanical Systems
Nasir Khanzada
07/30/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Nasir Khanzada
07/30/2026
Special inspection requirement — Footing and Foundation
Nasir Khanzada
07/30/2026
Special inspection requirement — Insulation placement and R values
Nasir Khanzada
07/30/2026
Special inspection requirement — Ventilation and air distribution system
MUZAFFAR JAMAL
07/30/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
Nasir Khanzada
07/30/2026
Special inspection requirement — HVAC-R and service water heating system controls
Nasir Khanzada
07/30/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
Nasir Khanzada
07/30/2026
Special inspection requirement — Concrete - Cast-In-Place
Nasir Khanzada
07/30/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Nasir Khanzada
07/30/2026
Special inspection requirement — Masonry
Nasir Khanzada
07/30/2026
Special inspection requirement — Subgrade Inspections
Nasir Khanzada
07/30/2026
Special inspection requirement — Energy Code Compliance Inspections
Nasir Khanzada
07/30/2026
Special inspection requirement — Final
Nasir Khanzada
07/30/2026
Special inspection requirement — Fire-Resistance Rated Construction
Nasir Khanzada
06/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/01/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
ALT 1 FILED TO PROPOSED ANCILLARY DWELLING UNIT (ADU) WITH EXISTING TWO-FAMILY HOUSE ATTACHED WITH THE PRIMARY BUILDING AT REAR AND SEPARATED BY A FIRE WALL
Q01261458-S1
05/01/2026
Objection resolved — Addressed
05/01/2026
Special inspection requirement — Excavations - Sheeting, Shoring, and Bracing
04/08/2026
Objection resolved — Addressed
04/01/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
03/20/2026
Objection resolved — Addressed
03/20/2026
Objection resolved — Addressed
03/10/2026
Filed — Alteration
Alt-2 filed for interior renovation with horizontal extension of an existing two-family house.
Q01173964-P4
02/26/2026
Special inspection requirement — Fenestration areas
02/26/2026
Special inspection requirement — Insulation placement and R values
02/26/2026
Special inspection requirement — Air barrier - visual inspection
02/26/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
02/26/2026
Special inspection requirement — Air barrier — testing
02/26/2026
Special inspection requirement — Fenestration air leakage
02/26/2026
Special inspection requirement — Ventilation and air distribution system
02/24/2026
Objection raised — Zoning
02/19/2026
Objection resolved — Resolved
02/19/2026
Objection resolved — Addressed
02/10/2026
Filed — Alteration
Alt-2 filed for interior renovation with horizontal extension of an existing two-family house.
Q01173964-P3
02/10/2026
Objection resolved — Addressed
02/06/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
02/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/23/2026
Objection resolved — Addressed
01/23/2026
Objection resolved — Addressed
01/19/2026
Objection resolved — Addressed
01/15/2026
Objection raised — Admin
01/15/2026
Objection raised — Admin
01/12/2026
Filed — Alteration
Alt-2 filed for interior renovation with horizontal extension of an existing two-family house.
Q01173964-P2
12/04/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
11/28/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/28/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
11/28/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
11/28/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/24/2025
Permit issued — General Construction
Q01173964-I1-GC
Latest 60 of 111 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedNOVELTY CONSTRUCTION CORP11/24/2025
DOB NOWEarth WorkPermit IssuedNOVELTY CONSTRUCTION CORP11/24/2025
DOB NOWFoundationPermit IssuedNOVELTY CONSTRUCTION CORP11/24/2025
DOB NOWConstruction FencePermit IssuedNOVELTY CONSTRUCTION CORP11/21/2025
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR11/20/2025
DOB NOWConstruction FencePermit IssuedNOVELTY CONSTRUCTION CORP05/23/2025
DOB NOWStructuralPermit IssuedNOVELTY CONSTRUCTION CORP05/21/2025
DOB NOWMechanical SystemsPermit IssuedNOVELTY CONSTRUCTION CORP05/21/2025
DOB NOWGeneral ConstructionPermit IssuedNOVELTY CONSTRUCTION CORP05/21/2025
DOB NOWMechanical SystemsPermit IssuedNOVELTY CONSTRUCTION CORP05/21/2025
2 projects · most recent 08/04/2026
Air Conditioning Systems Heating Systems Ventilation Systems Associated Ducts and Piping
FiledStatusContractorScopeMake / Model / Capacity
08/04/2026Permit IssuedNOVELTY CONSTRUCTION CORPAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Fujitsu ASU7RLF1 7,000 BTU · Fan Coil Indoor ×36
Heating
A.O. Smith GDHE-75 100,000 BTU · Water Heater ×6
Williamson GWA-70 70,000 BTU · Boiler ×6
Ventilation
Greenheck SP-C50-QD 50 CFM · Exhaust Fan ×15
SP-B90 100 CFM · Exhaust Fan ×6
05/01/2026——Air Conditioning Systems, Associated Ducts and Piping, Heating Systems, Ventilation Systems
Cooling
Goodman ASPT 39C14 5 tons · Fan Coil Indoor ×1
ASPT-49C14 4 tons · Fan Coil Indoor ×1
Heating
A.O. Smith GDHE 50 50,000 BTU · Water Heater ×2
Ventilation
Greenheck SP-C50-QD 50 CFM · Exhaust Fan ×5
SP-B90 100 CFM · Exhaust Fan ×2
Ducts & Piping
Weil-Mclain CGI-5 100,000 BTU · Boiler ×2
1 project · most recent 08/04/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/04/2026Signed-offINFINITI ESC PLUMBING CORGas, Storm, Water/Sanitary
1 project · most recent 06/02/2025
General Wiring
FiledStatusContractorScope
06/02/2025CompleteK.A.B. ELECTRIC CORPGeneral Wiring
2 projects · most recent 08/04/2026
Wood Concrete
FiledStatusContractorScope
08/04/2026Permit IssuedNOVELTY CONSTRUCTION CORPWood
05/01/2026——Concrete, Wood
1 project · most recent 05/19/2025
Fence
FiledStatusContractorScope
05/19/2025Permit IssuedNOVELTY CONSTRUCTION CORPFence
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
06/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/01/2026Fail-Final General Construction Non-Directive 14FailView ↗
02/06/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
12/04/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
11/28/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/28/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
11/28/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
11/28/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 76
DateRequirementInspectorRole
07/30/2026Fire-Resistant Penetrations and JointsNasir Khanzadaspecial
07/30/2026Excavations - Sheeting, Shoring, and BracingNasir Khanzadaspecial
07/30/2026Fenestration areasNasir Khanzadaenergy_progress
07/30/2026Concrete - Cast-In-PlaceNasir Khanzadaspecial
07/30/2026Interior lighting powerNasir Khanzadaenergy_progress
07/30/2026HVAC-R and service water piping design and insulationNasir Khanzadaenergy_progress
07/30/2026Insulation placement and R valuesNasir Khanzadaenergy_progress
07/30/2026Air barrier - visual inspectionNasir Khanzadaenergy_progress
07/30/2026HVAC-R and service water heating system controlsNasir Khanzadaenergy_progress
07/30/2026Fenestration air leakageNasir Khanzadaenergy_progress
07/30/2026HVAC-R and service water heating equipmentNasir Khanzadaenergy_progress
07/30/2026Electric vehicle service equipment requirementsNasir Khanzadaenergy_progress
07/30/2026Fenestration and door U-factor and product ratingsNasir Khanzadaenergy_progress
07/30/2026Footing and FoundationNasir Khanzadaprogress
07/30/2026Fire-Resistance Rated ConstructionNasir Khanzadaprogress
07/30/2026FinalNasir Khanzadaprogress
07/30/2026Energy Code Compliance InspectionsNasir Khanzadaprogress
07/30/2026Subgrade InspectionsNasir Khanzadaspecial
07/30/2026Structural Stability – Alterations of existing buildingsNasir Khanzadaspecial
07/30/2026Mechanical SystemsNasir Khanzadaspecial
07/30/2026Ventilation and air distribution systemMUZAFFAR JAMALenergy_progress
07/30/2026MasonryNasir Khanzadaspecial
05/01/2026Excavations - Sheeting, Shoring, and Bracing—special
02/26/2026Fenestration areas—energy_progress
02/26/2026Fenestration air leakage—energy_progress
Latest 25 of 76.
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch10
08/20/2026Q01173966-I1Request digital key ↗
08/17/2026Q01173964-I1Request digital key ↗
08/17/2026Q01173964-P5Request digital key ↗
Showing 3 of 10 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram4
08/17/2026Q01173964-I1Open ↗
08/17/2026Q01173964-P5Open ↗
08/17/2026Q01261458-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWRestrictive Declaration/Easement 13
08/17/2026Q01173964-P5Open ↗
08/17/2026Q01173964-I1Open ↗
08/13/2026Q01173964-P1Open ↗
▸Seals & Professional Certifications18
▸DOB NOWDPL-1: Design Professional Seal & Signature10
08/17/2026Q01173964-P2Open ↗
08/17/2026Q01173964-S1Open ↗
08/17/2026Q01173964-P5Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
08/29/2026Q01173964-I1Open ↗
08/29/2026Q01173964-I1Open ↗
08/29/2026Q01173964-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026Q01173964-I1Open ↗
08/23/2026Q01173964-P5Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report9
08/17/2026Q01173964-P5Open ↗
08/17/2026Q01173964-P3Open ↗
08/17/2026Q01173964-P2Open ↗
Showing 3 of 9 on file for this type
▸Other Documents8
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone3
08/17/2026Q01173964-I1Open ↗
08/17/2026Q01173964-P5Open ↗
08/13/2026Q01173964-P1Open ↗
▸DOB NOWSite Survey: Initial3
08/17/2026Q01173964-P5Open ↗
08/17/2026Q01173964-I1Open ↗
08/13/2026Q01173964-P1Open ↗
▸DOB NOWProperty Ownership Certification1
08/17/2026Q01261458-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/13/2026Q01173964-I1Open ↗