Roof20p · 2 filings · 20 docs
Fire ProtectionMechanical
Issued Permit Scope
Mechanical Systems · Sprinklers
SPRINKLER systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
11 documents
Mechanical systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
31 documents · 1 drawing sheet
Floor 327p · 3 filings · 20 docs
Fire ProtectionMechanicalPlumbing
Issued Permit Scope
Mechanical Systems · Plumbing · Sprinklers
APPLICATION IS FILED FOR NEW 2-FIXTURE BATHROOM IN CELLAR, NEW AND REPLACEMENT OF PLUMBING FIXTURES ON THE FIRST, SECOND, AND THIRD FLOORS TO EXISTING 3-STORY, 3-FAMILY WOOD FRAME RESIDENCE DUE TO FIRE DAMAGE. CHANGE IN USE OR OCCUPANCY FILED UNDER THIS
On file for this project
8 documents · 1 drawing sheet
SPRINKLER systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
11 documents · 1 drawing sheet
Mechanical systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
31 documents · 1 drawing sheet
Floor 226p · 3 filings · 20 docs
Fire ProtectionMechanicalPlumbing
Issued Permit Scope
Mechanical Systems · Plumbing · Sprinklers
APPLICATION IS FILED FOR NEW 2-FIXTURE BATHROOM IN CELLAR, NEW AND REPLACEMENT OF PLUMBING FIXTURES ON THE FIRST, SECOND, AND THIRD FLOORS TO EXISTING 3-STORY, 3-FAMILY WOOD FRAME RESIDENCE DUE TO FIRE DAMAGE. CHANGE IN USE OR OCCUPANCY FILED UNDER THIS
On file for this project
8 documents
SPRINKLER systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
11 documents · 1 drawing sheet
Mechanical systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
31 documents · 1 drawing sheet
Floor 128p · 3 filings · 20 docs
Fire ProtectionMechanicalPlumbing
Issued Permit Scope
Mechanical Systems · Plumbing · Sprinklers
APPLICATION IS FILED FOR NEW 2-FIXTURE BATHROOM IN CELLAR, NEW AND REPLACEMENT OF PLUMBING FIXTURES ON THE FIRST, SECOND, AND THIRD FLOORS TO EXISTING 3-STORY, 3-FAMILY WOOD FRAME RESIDENCE DUE TO FIRE DAMAGE. CHANGE IN USE OR OCCUPANCY FILED UNDER THIS
On file for this project
8 documents · 2 drawing sheets
SPRINKLER systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
11 documents · 1 drawing sheet
Mechanical systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
31 documents · 1 drawing sheet
Cellar28p · 3 filings · 20 docs
Fire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
Mechanical Systems · Plumbing · Sprinklers
APPLICATION IS FILED FOR NEW 2-FIXTURE BATHROOM IN CELLAR, NEW AND REPLACEMENT OF PLUMBING FIXTURES ON THE FIRST, SECOND, AND THIRD FLOORS TO EXISTING 3-STORY, 3-FAMILY WOOD FRAME RESIDENCE DUE TO FIRE DAMAGE. CHANGE IN USE OR OCCUPANCY FILED UNDER THIS
On file for this project
8 documents · 2 drawing sheets
SPRINKLER systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
11 documents · 1 drawing sheet
Mechanical systems are in conjunction with DOB Alteration type 2 job no # 340724602
On file for this project
31 documents · 1 drawing sheet
Site & exterior1p · 1 filing · 2 docs
Mechanical
Issued Permit Scope
Construction Fence
PROPOSED CONSTRUCTION FENCE. NO CHANGE TO USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
On file for this project
2 documents · 1 drawing sheet
Filed — no permit issued42p · 3 filings · 18 docs
ArchitectureGeneralStructuralOtherZ
No filed description on record for this project.
On file for this project
5 documents · 12 drawing sheets
APPLICATION IS FILED FOR THE CONVERSION OF EXISTING 3-STORY, 3-FAMILY RESIDENCE TO SINGLE-FAMILY RESIDENCE. . C.O. # (NONE ON RECORD) HPD # 246735.
On file for this project
10 documents · 12 drawing sheets
No filed description on record for this project.
On file for this project
3 documents · 5 drawing sheets