← Back
BuildNYC
Over six families without stores
14A MONROE STREET
BROOKLYN · BIN 3057061
💬 Discuss this project
1930Year Built
3Stories
C1Building Class
R6BZoning
2,700 sfGross Floor Area
8Units
0 Active ViolationsFDNY Report ↗
Over six families without stores · 1,840 sf lot · 1.47 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofRenovation8p · 3 filings · 20 docs
Floor 2Renovation9p · 2 filings · 20 docs
Floor 1Renovation6p · 2 filings · 20 docs
CellarRenovation15p · 3 filings · 20 docs
Sub-BasementRenovation8p · 3 filings · 20 docs
Site & exteriorRenovation5p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Path Place Architecture711/17/2025
Celin Munoz Consulting Engineering103/31/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Anzalone Architecture1603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Palm Home ImprovementGeneral Contractor407/08/2026
Joseph Weinstein ElectricElectrical103/22/2026
Infiniti Esc PlumbingPlumbing107/08/2026
Liquid Plumbing & Heating SCSPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Path Place Architecture8396711/17/2025
Celin Munoz Consulting EN1064103/31/2023
Building Lifecycle
All (64)Filed (8)Permit Issued (6)Signed Off (3)Violation (13)Inspection (4)Special Inspection (30)
12/03/2025
Signed off — Alteration
RENOVATE EXISTING ONE-FAMILY RESIDENCE. GENERAL CONSTRUCTION WORK INCLUDES DEMOLITION AND CONSTRUCTION OF NON-STRUCTURAL PARTITIONS, ENLARGEMENT OF OPENING AT REAR. INSTALL NEW SPLIT HVAC SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B08047303-I1
11/26/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
KELLEY SURUN
11/26/2025
Special inspection requirement — Fenestration areas
KELLEY SURUN
11/26/2025
Special inspection requirement — HVAC-R and service water heating equipment
KELLEY SURUN
11/26/2025
Special inspection requirement — Air barrier - visual inspection
KELLEY SURUN
11/26/2025
Special inspection requirement — Insulation placement and R values
KELLEY SURUN
11/26/2025
Special inspection requirement — HVAC-R and service water heating system controls
KELLEY SURUN
11/26/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
KELLEY SURUN
11/26/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
KELLEY SURUN
11/26/2025
Special inspection requirement — Fenestration air leakage
KELLEY SURUN
11/26/2025
Special inspection requirement — Interior lighting power
KELLEY SURUN
11/26/2025
Special inspection requirement — Energy Code Compliance Inspections
KELLEY SURUN
11/26/2025
Special inspection requirement — Final
KELLEY SURUN
11/26/2025
Special inspection requirement — Mechanical Systems
KELLEY SURUN
11/17/2025
Filed — Alteration
RENOVATE EXISTING ONE-FAMILY RESIDENCE. GENERAL CONSTRUCTION WORK INCLUDES DEMOLITION AND CONSTRUCTION OF NON-STRUCTURAL PARTITIONS, ENLARGEMENT OF OPENING AT REAR. INSTALL NEW SPLIT HVAC SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B08047303-P3
11/03/2025
Signed off — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION TO ONE FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION # B08047303-I1
B08047376-I1
10/21/2025
Signed off — Alteration
B08022165-I1
11/25/2024
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
10/07/2024
Permit issued — Plumbing
B08047376-I1-PL
07/08/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
KELLEY SURUN
07/08/2024
Special inspection requirement — Energy Code Compliance Inspections
KELLEY SURUN
07/08/2024
Special inspection requirement — Maintenance information
KELLEY SURUN
07/08/2024
Special inspection requirement — HVAC-R and service water heating system controls
KELLEY SURUN
07/08/2024
Special inspection requirement — HVAC-R and service water heating equipment
KELLEY SURUN
07/08/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
KELLEY SURUN
07/02/2024
Filed — Alteration
RENOVATE EXISTING ONE-FAMILY RESIDENCE. GENERAL CONSTRUCTION WORK INCLUDES DEMOLITION AND CONSTRUCTION OF NON-STRUCTURAL PARTITIONS, ENLARGEMENT OF OPENING AT REAR. INSTALL NEW SPLIT HVAC SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B08047303-P2
07/02/2024
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION TO ONE FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION # B08047303-I1
B08047376-P2
03/20/2024
Permit issued — Mechanical Systems
B08047303-I1-GC-CX
03/11/2024
Permit issued — Structural
B08022165-I1-ST
01/08/2024
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION TO ONE FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION # B08047303-I1
B08047376-P1
12/28/2023
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
12/28/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
12/27/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
KELLEY SURUN
12/27/2023
Special inspection requirement — HVAC-R and service water heating system controls
KELLEY SURUN
12/27/2023
Special inspection requirement — HVAC-R and service water piping design and insulation
KELLEY SURUN
12/27/2023
Special inspection requirement — Maintenance information
KELLEY SURUN
12/27/2023
Special inspection requirement — HVAC-R and service water heating equipment
KELLEY SURUN
12/27/2023
Special inspection requirement — Energy Code Compliance Inspections
KELLEY SURUN
08/30/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/17/2023
Permit issued — Plumbing
B08047376-I1-PL
07/18/2023
Permit issued — Structural
B08022165-I1-ST
07/18/2023
Permit issued — Mechanical Systems
B08047303-I1-GC-CX
07/12/2023
Filed — Alteration
RENOVATE EXISTING ONE-FAMILY RESIDENCE. GENERAL CONSTRUCTION WORK INCLUDES DEMOLITION AND CONSTRUCTION OF NON-STRUCTURAL PARTITIONS, ENLARGEMENT OF OPENING AT REAR. INSTALL NEW SPLIT HVAC SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B08047303-P1
07/12/2023
Special inspection requirement — HVAC-R and service water heating system controls
KELLEY SURUN
07/12/2023
Special inspection requirement — HVAC-R and service water heating equipment
KELLEY SURUN
07/12/2023
Special inspection requirement — Insulation placement and R values
KELLEY SURUN
07/12/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
KELLEY SURUN
07/12/2023
Special inspection requirement — Final
KELLEY SURUN
03/31/2023
Filed — Alteration
B08022165-I1
01/25/2023
Filed — Alteration
RENOVATE EXISTING ONE-FAMILY RESIDENCE. GENERAL CONSTRUCTION WORK INCLUDES DEMOLITION AND CONSTRUCTION OF NON-STRUCTURAL PARTITIONS, ENLARGEMENT OF OPENING AT REAR. INSTALL NEW SPLIT HVAC SYSTEM. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
B08047303-I1
01/25/2023
Filed — Alteration
PLUMBING WORK FILED IN CONJUNCTION WITH RENOVATION TO ONE FAMILY RESIDENCE. INSTALL PLUMBING FIXTURES AND RELATED PIPING. GENERAL CONSTRUCTION FILED UNDER SEPARATE APPLICATION # B08047303-I1
B08047376-I1
03/01/2022
Violation issued (HPD, closed)
A
03/01/2022
Violation issued (HPD, closed)
I
04/12/2021
Violation issued (HPD, closed)
A
06/26/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
04/04/2019
Violation issued (ECB, closed)
Construction
10/13/2015
Violation issued (HPD, closed)
I
12/31/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
12/21/2007
Violation issued (ECB, closed)
Construction
03/16/2007
Violation issued (DOB, closed)
V%*-DOB VIOLATION - DISMISSED
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offLiquid Plumbing & Heating SCS10/07/2024
DOB NOWMechanical SystemsSigned-offPalm Home Improvement03/20/2024
DOB NOWStructuralSigned-offPalm Home Improvement03/11/2024
DOB NOWPlumbingSigned-offInfiniti Esc Plumbing08/17/2023
DOB NOWStructuralSigned-offPalm Home Improvement07/18/2023
DOB NOWMechanical SystemsSigned-offPalm Home Improvement07/18/2023
BISPLISSUEDDJC05/24/2018
BIS—ISSUEDN/A05/26/2017
BISEQISSUEDTri-State Contracting of*05/12/2014
3 projects · most recent 08/25/2023
General Wiring
FiledStatusContractorScope
08/25/2023Permit IssuedTriple D ElectricGeneral Wiring
02/19/2020CompleteJoseph Weinstein ElectricGeneral Wiring
02/06/2020CompleteJoseph Weinstein ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 4
DateTypeResultReport
11/25/2024Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/28/2023Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/28/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/30/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
11/26/2025Fire-Resistant Penetrations and JointsKELLEY SURUNspecial
11/26/2025Fenestration areasKELLEY SURUNenergy_progress
11/26/2025HVAC-R and service water heating equipmentKELLEY SURUNenergy_progress
11/26/2025Air barrier - visual inspectionKELLEY SURUNenergy_progress
11/26/2025Insulation placement and R valuesKELLEY SURUNenergy_progress
11/26/2025HVAC-R and service water heating system controlsKELLEY SURUNenergy_progress
11/26/2025HVAC-R and service water piping design and insulationKELLEY SURUNenergy_progress
11/26/2025Fenestration and door U-factor and product ratingsKELLEY SURUNenergy_progress
11/26/2025Fenestration air leakageKELLEY SURUNenergy_progress
11/26/2025Interior lighting powerKELLEY SURUNenergy_progress
11/26/2025Energy Code Compliance InspectionsKELLEY SURUNprogress
11/26/2025FinalKELLEY SURUNprogress
11/26/2025Mechanical SystemsKELLEY SURUNspecial
07/08/2024Fire-Resistant Penetrations and JointsKELLEY SURUNspecial
07/08/2024Energy Code Compliance InspectionsKELLEY SURUNprogress
07/08/2024Maintenance informationKELLEY SURUNenergy_progress
07/08/2024HVAC-R and service water heating system controlsKELLEY SURUNenergy_progress
07/08/2024HVAC-R and service water heating equipmentKELLEY SURUNenergy_progress
07/08/2024HVAC-R and service water piping design and insulationKELLEY SURUNenergy_progress
12/27/2023Fire-Resistant Penetrations and JointsKELLEY SURUNspecial
12/27/2023HVAC-R and service water heating system controlsKELLEY SURUNenergy_progress
12/27/2023HVAC-R and service water piping design and insulationKELLEY SURUNenergy_progress
12/27/2023Maintenance informationKELLEY SURUNenergy_progress
12/27/2023HVAC-R and service water heating equipmentKELLEY SURUNenergy_progress
12/27/2023Energy Code Compliance InspectionsKELLEY SURUNprogress
Latest 25 of 38.
▾Documents — 97 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch8
08/27/2026B08047303-I1Request digital key ↗
08/27/2026B08047303-P2Request digital key ↗
08/27/2026B08047303-P3Request digital key ↗
Showing 3 of 8 on file for this type
▸Applications & Permits14
▸BISPLAN / WORK APPROVAL APPLICATION10
12/23/2020321242366Open ↗
12/17/2020321242366Open ↗
08/18/2020321242366Open ↗
Showing 3 of 10 on file for this type
▸BISWORK PERMIT APPLICATION3
06/12/2018321242366Open ↗
06/02/2017321242366Open ↗
05/09/2014340142198Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
06/16/2017321242366Open ↗
▸Zoning, Tax Lot & Property Records1
▸BISADDRESS - NEW HOUSE NUMBER APPROVED1
02/01/2011320254096Open ↗
▸Seals & Professional Certifications27
▸DOB NOWDPL-1: Design Professional Seal & Signature8
08/27/2026B08047303-I1Open ↗
08/27/2026B08047303-P2Open ↗
08/27/2026B08047303-P3Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature8
09/01/2026B08047303-I1Open ↗
09/01/2026B08047303-I1Open ↗
08/31/2026B08047376-I1Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
04/26/2019321242366Open ↗
04/26/2019321242366Open ↗
10/02/2015321242366Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature4
09/01/2026B08047303-I1Open ↗
08/31/2026B08047376-I1Open ↗
08/24/2026B08047376-P1Open ↗
Showing 3 of 4 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
05/09/2014340142198Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
05/09/2014340142198Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/09/2014340142198Open ↗
▸Trade Schedules & Equipment3
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
03/03/2016321242366Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
04/26/2019321242366Open ↗
▸BISSCHEDULE B - PLUMBING1
02/01/2011320254096Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
10/04/2016321242366Open ↗
02/01/2011320254096Open ↗
▸BISANTI-HARASSMENT CHECKLIST1
02/01/2011320254096Open ↗
▸Environmental & Asbestos9
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/27/2026B08047303-I1Open ↗
08/27/2026B08047303-P3Open ↗
08/27/2026B08047303-P1Open ↗
Showing 3 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
02/01/2011320254096Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
04/26/2019321242366Open ↗
06/02/2017321242366Open ↗
10/02/2015321242366Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/26/2019321242366Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
08/11/2020340142198Open ↗
08/11/2020340142198Open ↗
05/09/2014340142198Open ↗
▸Approvals, Objections & Sign-offs10
▸BISSCHEDULE A - OCCUPANCY / USE5
12/23/2020321242366Open ↗
08/18/2020321242366Open ↗
08/13/2020321242366Open ↗
Showing 3 of 5 on file for this type
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST4
08/11/2020340142198Open ↗
10/30/2019321242366Open ↗
07/25/2019321242366Open ↗
Showing 3 of 4 on file for this type
▸BISADMINISTRATIVE OBJECTIONS1
02/01/2011320254096Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
06/05/2020321242366Open ↗
04/26/2019321242366Open ↗
10/02/2015321242366Open ↗
▸Filing & Intake Forms9
▸BISBOROUGH INTAKE FORM3
10/30/2019321242366Open ↗
07/25/2019321242366Open ↗
04/26/2019321242366Open ↗
▸BISEFILING COVER SHEET3
03/03/2016321242366Open ↗
10/02/2015321242366Open ↗
02/01/2011320254096Open ↗
▸BISADDITIONAL INFORMATION2
04/16/2019321242366Open ↗
06/02/2017321242366Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
05/09/2014340142198Open ↗
▸Other Documents3
▸BISPLOT DIAGRAM2
10/02/2015321242366Open ↗
02/01/2011320254096Open ↗
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION1
09/20/2016321242366Open ↗