← Back
School or academy
Rudolf Steiner School
15 EAST 79 STREET · Name © OpenStreetMap contributors · Upper East Side-Carnegie Hill · BIN 1046429
💬 Discuss this project
1916Year Built
5Stories
W3Building Class
R10Zoning
14,651 sfGross Floor Area
1Units
5 Open Violations ▸
School or academy · 3,883 sf lot · 3.77 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Roof23p · 2 filings · 17 docs
Floor 220p · 2 filings · 17 docs
Floor 121p · 2 filings · 17 docs
Cellar38p · 5 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RUDOLF STEINER SCHOOL2603/21/2026
RUDOLPH STEINER SCHOOL103/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LORING CONSULTING ENGINEERS, INC.1009/12/2023
CANNON ARCHITECTURE STUDIO104/28/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ALPHACRAFT CONSTRUCTION*General Contractor1407/08/2026
VELOCITY PLUMBING & HEATPlumbing507/08/2026
THOMAS FAYFire Protection203/21/2026
APPELBAUM, DAVIDElectrical103/21/2026
ANESIS SERVICES CORPFire Protection107/08/2026
NYC DEPT OF CORRECTIONElectrical103/21/2026
WALTER KNITTELElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CATALPA SPECIAL INSPECTIO2004909/12/2023
MEP INSPECTIONS, INC1102406/13/2023
Building Lifecycle
All (90)Filed (11)Permit Issued (12)Signed Off (4)Violation (23)Inspection (9)Objection (22)Special Inspection (9)
09/12/2023
Filed — Alteration
Remove and install Mech/Hvac equipment, Units, ductwork, exhaust fans, supports and associated piping, steel dunnage related to school renovation per plans filed herewith.
M00495918-P1
08/08/2023
Signed off — Alteration
MODIFICATION TO EXISTING SPRINKLER SYSTEM
M00495985-I1
06/13/2023
Filed — Alteration
MODIFICATION TO EXISTING SPRINKLER SYSTEM
M00495985-P3
06/06/2023
Special inspection requirement — Sprinkler Systems
Nicolas Crosetto
06/06/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
12/16/2022
Signed off — Alteration
INSTALL 1 SOLENOID VALVE FOR WATER HEATER.
M00674711-I1
12/16/2022
Signed off — Alteration
Modification to existing plumbing system related to school renovation per plans filed herewith.
M00495967-I1
12/06/2022
Signed off — Alteration
Remove and construct interior partitions and hung ceilings related to school renovation per plans filed herewith.
M00495870-I1
11/08/2022
Filed — Alteration
INSTALL 1 SOLENOID VALVE FOR WATER HEATER.
M00674711-P1
08/16/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/21/2022
Permit issued — Plumbing
M00674711-I1-PL
04/19/2022
Permit issued — Plumbing
M00495967-I1-PL
03/23/2022
Permit issued — Plumbing
M00495967-I1-PL
03/11/2022
Permit issued — Plumbing
M00495967-I1-PL
02/21/2022
Permit issued — Mechanical Systems
M00495918-I1-MS
02/21/2022
Permit issued — General Construction
M00495870-I1-GC
02/14/2022
Filed — Alteration
INSTALL 1 SOLENOID VALVE FOR WATER HEATER.
M00674711-I1
01/31/2022
Filed — Alteration
MODIFICATION TO EXISTING SPRINKLER SYSTEM
M00495985-P2
01/05/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
01/05/2022
Special inspection requirement — Sprinkler Systems
Nicolas Crosetto
11/12/2021
Objection raised — Other
11/12/2021
Objection resolved — Addressed
11/10/2021
Permit issued — General Construction
M00495870-I1-GC
11/10/2021
Permit issued — Mechanical Systems
M00495918-I1-MS
11/08/2021
Filed — Alteration
Modification to existing plumbing system related to school renovation per plans filed herewith.
M00495967-P1
11/08/2021
Filed — Alteration
MODIFICATION TO EXISTING SPRINKLER SYSTEM
M00495985-P1
10/08/2021
Special inspection requirement — Sprinkler Systems
Nicolas Crosetto
10/08/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
09/27/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/27/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
ERIC BERLENT
09/17/2021
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/08/2021
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/08/2021
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
09/03/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/25/2021
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/23/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
06/18/2021
Permit issued — Sprinklers
M00495985-I1-EW-SP
06/15/2021
Permit issued — Plumbing
M00495967-I1-PL
06/11/2021
Permit issued — Mechanical Systems
M00495918-I1-MS
05/27/2021
Permit issued — General Construction
M00495870-I1-GC
05/26/2021
Objection raised — Other
05/26/2021
Objection resolved — Addressed
05/26/2021
Objection raised — Other
05/26/2021
Objection resolved — Addressed
05/20/2021
Filed — Alteration
MODIFICATION TO EXISTING SPRINKLER SYSTEM
M00495985-I1
05/20/2021
Filed — Alteration
Modification to existing plumbing system related to school renovation per plans filed herewith.
M00495967-I1
05/20/2021
Filed — Alteration
Remove and install Mech/Hvac equipment, Units, ductwork, exhaust fans, supports and associated piping, steel dunnage related to school renovation per plans filed herewith.
M00495918-I1
05/12/2021
Objection raised — Other
05/12/2021
Objection resolved — Addressed
05/06/2021
Objection raised — Accessibility
05/06/2021
Objection resolved — Addressed
05/06/2021
Objection raised — Inspections
05/06/2021
Objection resolved — Addressed
05/06/2021
Objection raised — Fire_Protection
05/06/2021
Objection resolved — Addressed
05/06/2021
Objection raised — Other
05/06/2021
Objection resolved — Addressed
05/06/2021
Objection raised — Accessibility
05/06/2021
Objection resolved — Addressed
Latest 60 of 90 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offVELOCITY PLUMBING & HEAT07/21/2022
DOB NOWPlumbingSigned-offVELOCITY PLUMBING & HEAT04/19/2022
DOB NOWPlumbingSigned-offVELOCITY PLUMBING & HEAT03/23/2022
DOB NOWPlumbingSigned-offVELOCITY PLUMBING & HEAT03/11/2022
DOB NOWMechanical SystemsSigned-offALPHACRAFT CONSTRUCTION*02/21/2022
DOB NOWGeneral ConstructionSigned-offALPHACRAFT CONSTRUCTION*02/21/2022
DOB NOWGeneral ConstructionSigned-offALPHACRAFT CONSTRUCTION*11/10/2021
DOB NOWMechanical SystemsSigned-offALPHACRAFT CONSTRUCTION*11/10/2021
DOB NOWSprinklersSigned-offTHOMAS FAY06/18/2021
DOB NOWPlumbingSigned-offVELOCITY PLUMBING & HEAT06/15/2021
DOB NOWMechanical SystemsSigned-offALPHACRAFT CONSTRUCTION*06/11/2021
DOB NOWGeneral ConstructionSigned-offALPHACRAFT CONSTRUCTION*05/27/2021
BISOTISSUEDMID COUNTY MECHANICAL COR10/12/2011
BISOTISSUEDVILES CONTRACTING CORP08/02/2011
BISOTISSUEDVILES CONTRACTING CORP08/24/2010
BISEQISSUEDJOVIL CONTRACTING CORP07/22/2010
BISEQISSUEDJOVIL CONTRACTING CORP07/21/2010
BISOTISSUEDAM BUILDING MAINTENANCE07/31/2007
BISOTISSUEDHESSE CONTRACTING INC.07/11/2006
BISEQISSUEDOUTDOOR INSTALLATIONS LLC07/11/2006
BISFPISSUEDFIREMASTERS09/16/2005
BISPLISSUEDPLUMBING & HTG DOCTOR INC07/06/2005
BISOTISSUEDNO STRESS LLC D/B/A CONSTRUCTION06/27/2005
BISOTISSUEDNO STRESS LLC D/B/A CONSTRUCTION06/27/2005
BISMHISSUEDNO STRESS LLC D/B/A CONSTRUCTION06/27/2005
BISOTISSUEDALCON BUILD. GROUP J08/10/2004
BISMHISSUEDALCON BUILD. G ROUP INC.08/10/2004
BISOTISSUEDALCON BUILD. GROUP08/10/2004
BISPLISSUEDZ.W. PLBG & HTG CORP06/09/2004
BISOTISSUEDALCON BUILD. GROUP05/17/2004
BISOTISSUEDALCON BUILD. GROUP J05/17/2004
BISMHISSUEDALCON BUILD. G ROUP INC.05/17/2004
BISEQISSUEDCLARK AND WILKINS INDUSTRIES INC07/09/2003
BISPLISSUEDECONOMY P & H CO.,INC08/29/2002
BISFBISSUEDMID-COUNTY MECHANICAL CO08/29/2002
BISFBISSUEDMID-COUNTY MECHANICAL CO05/31/2001
BISPLISSUEDECONOMY P & H CO.,INC05/15/2001
BISPLRE-ISSUEDS&H PLBG & HTG INC.08/28/2000
BISMHRE-ISSUEDPIERHEAD ASSOCIATES LTD08/22/2000
BISOTISSUEDMID COUNTY MECHANICAL COR06/23/1997
+ 3 more permits on file
1 project · most recent 09/12/2023
Air Conditioning Systems Associated Ducts and Piping Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
09/12/2023Signed-offALPHACRAFT CONSTRUCTION*Air Conditioning Systems, Associated Ducts and Piping, Heating Systems
Cooling
Trane TPEFYP0489A143A 1,270 CFM · Vrf Indoor ×2
TPEFYPO96MH140A 2,540 CFM · Vrf Indoor ×2
TSC120H3RGA2606D0000000C 00000D0000000000 3,200 CFM · Rooftop Unit ×2
Loren Cook 100KSP10KSP-B 2,200 CFM · Makeup Air ×2
Mitsubishi Electric TRUYA0301HA70NA 25 tons · Vrf Outdoor ×2
Smartflex TPKA0A0301KA70A 28,000 BTU ×2
Heating
Mitsubishi Electric TUMYP0481AK43NA 47,100 BTU · Heat Pump Outdoor ×2
Trane HVAHP096B32S 47,100 BTU · Heat Pump Outdoor ×2
Ducts & Piping
N/A N/A ×2
1 project · most recent 08/04/2021
General Wiring
FiledStatusContractorScope
08/04/2021Permit IssuedBANNER ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
08/16/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/27/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/17/2021Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/08/2021Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/08/2021Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/03/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/25/2021Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/23/2021Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
06/06/2023Sprinkler SystemsNicolas Crosettospecial
06/06/2023Fire-Resistant Penetrations and JointsERIC BERLENTspecial
01/05/2022Fire-Resistant Penetrations and JointsERIC BERLENTspecial
01/05/2022Sprinkler SystemsNicolas Crosettospecial
10/08/2021Sprinkler SystemsNicolas Crosettospecial
10/08/2021Fire-Resistant Penetrations and JointsERIC BERLENTspecial
09/27/2021Fire-Resistant Penetrations and JointsERIC BERLENTspecial
04/01/2021Fire-Resistant Penetrations and JointsERIC BERLENTspecial
03/31/2021FinalKevin Cannonprogress
▾Tenants in the building
TenantSpaceFloorsRenovation projects
Rudolf Steiner SchoolEducationCellar, Floors 1, 2, Roof
Project M00495870 Alteration · LOC Issued · 04/28/2021
Read from each project’s drawing title blocks and cover sheets and checked twice; a name appears only when it is the occupant, never the owner, landlord or designer.
▾Documents — 102 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
09/03/2026M00495918-I1Request digital key ↗
09/03/2026M00495918-P1Request digital key ↗
09/03/2026M00495967-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits15
▸BISWORK PERMIT APPLICATION6
10/13/2011120823984Open ↗
10/13/2011120823984Open ↗
08/08/2011120406630Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLPC Approval/Permit5
09/03/2026M00495918-P1Open ↗
09/03/2026M00495918-I1Open ↗
08/13/2026M00495967-I1Open ↗
Showing 3 of 5 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION4
09/23/2011120823984Open ↗
07/26/2010120420311Open ↗
07/22/2010120415666Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications32
▸DOB NOWDPL-1: Design Professional Seal & Signature11
09/03/2026M00495918-P1Open ↗
09/03/2026M00495918-I1Open ↗
09/03/2026M00495967-I1Open ↗
Showing 3 of 11 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026M00495985-P2Open ↗
09/01/2026M00495985-P2Open ↗
09/01/2026M00495985-P3Open ↗
Showing 3 of 8 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
09/23/2011120823984Open ↗
08/26/2010120406630Open ↗
07/26/2010120420311Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST4
09/23/2011120823984Open ↗
07/26/2010120420311Open ↗
07/22/2010120415666Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM4
09/23/2011120823984Open ↗
07/26/2010120420311Open ↗
07/22/2010120415666Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProgress Inspector Seal & Signature1
08/31/2026M00495870-I1Open ↗
▸Environmental & Asbestos18
▸DOB NOWDEP ACP-5: Asbestos Assessment Report11
09/03/2026M00495918-P1Open ↗
09/03/2026M00495918-I1Open ↗
09/03/2026M00495967-I1Open ↗
Showing 3 of 11 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'6
09/23/2011120823984Open ↗
09/23/2011120823984Open ↗
09/23/2011120823984Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
07/22/2010120415666Open ↗
▸Energy Compliance1
▸BISTECHNICAL REPORT: ENERGY1
09/23/2011120823984Open ↗
▸Approvals, Objections & Sign-offs17
▸DOB NOWFee Exempt Supporting Document - DOF ACRIS report or BIB letter11
09/03/2026M00495918-P1Open ↗
09/03/2026M00495918-I1Open ↗
09/03/2026M00495967-I1Open ↗
Showing 3 of 11 on file for this type
▸BISADMINISTRATIVE OBJECTIONS4
09/23/2011120823984Open ↗
07/26/2010120420311Open ↗
07/22/2010120415666Open ↗
Showing 3 of 4 on file for this type
▸BISLANDMARKS APPROVAL2
10/12/2011120823984Open ↗
07/12/2010120406630Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
09/23/2011120823984Open ↗
07/21/2010120406630Open ↗
▸Filing & Intake Forms6
▸BISEFILING COVER SHEET5
09/23/2011120823984Open ↗
07/26/2010120420311Open ↗
07/22/2010120415666Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION1
10/14/2011120823984Open ↗