← Back
One family attached or semi-detached
15 IMPERIAL COURT
STATEN ISLAND · BIN 5146369
💬 Discuss this project
2006Year Built
2Stories
A5Building Class
R3-2Zoning
1,288 sfGross Floor Area
1Units
One family attached or semi-detached · 2,450 sf lot · 0.53 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingGeneral
Floor 23p · 2 filings · 20 docs
Floor 11p · 1 filing · 12 docs
Basement6p · 2 filings · 20 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
BASSIRI710/29/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ECDESIGN STUDIO1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
AMC PLBG, HTG & CLNG, INCPlumbing907/08/2026
ALEX WUElectrical103/21/2026
STAR UNIVERSE RENOVATION*General Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BASSIRI8394309/16/2025
Building Lifecycle
All (26)Filed (7)Permit Issued (2)Signed Off (2)Inspection (6)Special Inspection (9)
12/10/2025
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW WASHER AND HOT WATER HEATERS IN BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243780-I1
10/29/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW WASHER AND HOT WATER HEATERS IN BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243780-P3
10/16/2025
Signed off — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243778-I1
10/14/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
10/07/2025
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
09/29/2025
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
09/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
09/17/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
09/17/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
09/16/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243778-P2
09/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
09/16/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
09/16/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
08/19/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
08/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
08/19/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/14/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW WASHER AND HOT WATER HEATERS IN BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243780-P2
08/12/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW WASHER AND HOT WATER HEATERS IN BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243780-P1
08/12/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243778-P1
08/12/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
FARHAD BASSIRI-TEHRANI
08/12/2025
Special inspection requirement — Energy Code Compliance Inspections
FARHAD BASSIRI-TEHRANI
08/12/2025
Special inspection requirement — Fire-Resistance Rated Construction
FARHAD BASSIRI-TEHRANI
07/02/2025
Permit issued — Plumbing
S01243780-I1-PL
07/02/2025
Permit issued — General Construction
S01243778-I1-GC
06/19/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH PLUMBING WORK: REPLACE KITCHEN AND BATHROOM FIXTURES; NEW WASHER AND HOT WATER HEATERS IN BASEMENT; NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243780-I1
06/19/2025
Filed — Alteration
RENOVATION OF EXISTING BASEMENT, FIRST AND SECOND FLOOR WITH GENERAL CONSTRUCTION AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY UNDER THIS APPLICATION.
S01243778-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAMC PLBG, HTG & CLNG, INC07/02/2025
DOB NOWGeneral ConstructionSigned-offSTAR UNIVERSE RENOVATION*07/02/2025
BISOTISSUEDWALLACE AVENUE CONSTR LLC12/14/2007
BIS—ISSUEDOSGOOD PARK LLC09/11/2006
BISPLISSUEDDUO PLUMBING & HTG CORP.04/24/2006
1 project · most recent 09/05/2025
General Wiring
FiledStatusContractorScope
09/05/2025CompleteFIRST STAR ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
10/14/2025Pass-Final General Construction Non-Directive 14PassView ↗
10/07/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
09/29/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
08/19/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
08/19/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
08/19/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
09/17/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/17/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
09/17/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
09/16/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
09/16/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
09/16/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
08/12/2025Fire-Resistant Penetrations and JointsFARHAD BASSIRI-TEHRANIspecial
08/12/2025Energy Code Compliance InspectionsFARHAD BASSIRI-TEHRANIprogress
08/12/2025Fire-Resistance Rated ConstructionFARHAD BASSIRI-TEHRANIprogress
▾Documents — 20 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/18/2026S01243778-P2Request digital key ↗
08/18/2026S01243778-P1Request digital key ↗
08/18/2026S01243778-I1Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications13
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/18/2026S01243778-P1Open ↗
08/18/2026S01243778-I1Open ↗
08/18/2026S01243780-P1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature3
09/23/2026S01243778-P2Open ↗
09/01/2026S01243778-I1Open ↗
08/25/2026S01243778-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature3
09/23/2026S01243778-P2Open ↗
09/01/2026S01243778-I1Open ↗
08/25/2026S01243778-P1Open ↗