Locations of Work
StructuralPlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 23p · 2 filings · 12 docs
Floor 1Roadway and sidewalk maintenance and protection3p · 3 filings · 14 docs
Cellar3p · 2 filings · 12 docs
Site & exterior2p · 1 filing · 8 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Waterside Estates @ Cresthaven203/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Fang Architect304/06/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
HP ServicesPlumbing507/08/2026
Dve ConstructionGeneral Contractor303/21/2026
Norton Mechanical IIPlumbing109/17/2003
Waterside Estates & CresthavenGeneral Contractor209/10/2003
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Fang Architect5513210/20/2022
Building Lifecycle
04/06/2026
Filed — Alteration
INSTALL (1) 10.0' WIDE NEW CURB CUT.
Q01284645-I1
07/07/2025
Signed off — Alteration
FILE PLUMBING WORK FOR EXISTING ONE FAMILY DWELLING. FILED IN CONJUNCTION WITH GC JOB #Q08020045.
Q08021950-I1
07/24/2024
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/04/2023
Permit expired, never signed off — Foundation
The city's record still shows this permit as issued, with no sign-off on its filing
Q08020045-I1-GC-CX
02/03/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
26 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHP Services11/21/2022
DOB NOWFoundationPermit IssuedDve Construction11/04/2022
BISPLISSUEDNorton Mechanical II09/17/2003
BIS—ISSUEDWaterside Estates & Cresthaven09/10/2003
BISEQISSUEDWaterside Estates & Cresthaven09/10/2003
1 project · most recent 11/08/2022
FiledStatusContractorScope
11/08/2022CompleteR & T Electrical—
1 project · most recent 10/13/2022
Steel
FiledStatusContractorScope
10/13/2022Permit IssuedDve ConstructionSteel
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
07/24/2024Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
02/03/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/03/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/17/2022Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
10/17/2022Energy Code Compliance InspectionsDEZHANG FANGprogress
10/12/2022Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
10/12/2022Structural Steel - High Strength BoltingDEZHANG FANGspecial
10/12/2022FinalDEZHANG FANGprogress
10/12/2022Footing and FoundationDEZHANG FANGprogress
10/12/2022Energy Code Compliance InspectionsDEZHANG FANGprogress
10/12/2022Fire-Resistance Rated ConstructionDEZHANG FANGprogress
10/12/2022Structural Steel - DetailsDEZHANG FANGspecial
10/12/2022Fenestration areasDEZHANG FANGenergy_progress
10/12/2022Air barrier - visual inspectionDEZHANG FANGenergy_progress
10/12/2022Fenestration air leakageDEZHANG FANGenergy_progress
10/12/2022Insulation placement and R valuesDEZHANG FANGenergy_progress
10/12/2022Interior lighting powerDEZHANG FANGenergy_progress
10/12/2022Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
10/12/2022Concrete - Cast-In-PlaceDEZHANG FANGspecial